Differential sensor, WT0120-A00-B00-C06-D10 $r $n differential sensor WT0122-A50-B00-C01,WT0182-A50-B00-C01,WT0120-A00-B00-C06-D10,WT0120-A00-B00-C06-D10 The sensor outputs a voltage signal proportional to the distance between the probe end and the surface of the measured conductor, which can be used for both static (displacement) and dynamic (vibration) measurements. It is mainly used to measure the relative vibration, displacement, key phase, and rotational speed of sliding bearing machinery
Product Details

Price difference sensor, WT0120-A00-B00-C06-D10

Differential sensor WT0122-A50-B00-C01,WT0182-A50-B00-C01,

WT0120-A00-B00-C06-D10,WT0120-A00-B00-C06-D10

The sensor outputs a voltage signal proportional to the distance between the probe end and the surface of the measured conductor, which can be used for both static (displacement) and dynamic (vibration) measurements. It is mainly used to measure the relative vibration, displacement, key phase, and rotational speed of sliding bearing machinery; And the runout of the water turbine unit is suitable for industrial sites under high temperature conditions. All negative voltage output type eddy current sensors comply with the 670 standard established by the American Petroleum Institute (API) for such sensors. Sensors can be connected to secondary differential expansion instruments (monitors), signal conditioners (transmitters), and testing instrument inputs to form a complete equipment status monitoring system

Standard specimen material: 45 # steel or 42CrMO steel (AISI 4140) Interchangeability error: Sensitivity generated by exchanging calibrated probes, extension cables, and preamplifiers of the same model within a 5-meter or 9-meter system. Ripple: ≤ 20mV, temperature drift: ≤ 0.05%/℃, preamplifier output impedance: 50 Ω, preamplifier to monitor on-site connection: allowed for 300 meters, electromagnetic compatibility: compliant with CE standards, isolation: ground insulation, installation safety approval: intrinsic safety Exia Ⅱ C T4, when used in hazardous areas, install intrinsic safety barriers.

Probe End Material: PPS Probe Shell Material: 304 Stainless Steel Probe Cable and Extension Cable: 75 Ω Three Dimensional Axial Insulated Cable Armor Material: 304 Stainless Steel Preacher Shell Material: There are two types of shells, aluminum die-casting or ABS plastic shell Coaxial Joint Material: gold-plated brass or beryllium copper

Installation form of probe: 06 British formal, 1/4 "-28 metric formal, M8 × 1 British reverse, 3/8" -24 metric reverse, M10 × 1 British formal, 3/8 "-24 metric formal, M10 × 1B: Non threaded length 002250 metric formal threaded probe, increasing by 2mm or 5mm units, 2mm250mm British formal threaded probe, increasing by 0.1inch units 010 0.1in960 9.6in008020 metric reverse threaded probe fixed standard specification 8mm British reverse threaded probe fixed standard specification 0.2inE: connector and cable 010200 without connector, standard cable with coaxial locking connector, other connectors and cable A: TM3108T probe installation form British formal, 3/8" -24 Metric formal attire, M10 × 1 imperial reverse installation, 3/8 "-24 metric reverse installation, M10 × 1 clamped outlet shell diameter 9.6mm C: shell length 02025020mm TM3111T25mm250mm imperial formal threaded probe, increasing by 0.1inch 080960 9.6in030120 metric reverse threaded probe fixed standard specification 30mm imperial reverse threaded probe fixed standard specification 1.2in metric formal threaded probe, increasing by 2mm or 5mm 0.8in TM3111T1.00inF: armored 0100 without armor, reverse mounted probe is non armored stainless steel flexible armor A: TM3111T probe installation form 06 imperial formal installation, 1/2" -20 NFT metric formal installation, M14 × 1.5 imperial reverse installation, 3/8 "-24 UNF metric reverse installation, M10 × 1 imperial formal installation, 5/8" -18 UNF metric formal installation, M16 × 1.5D: The total length of the probe increases by 0.5m units 9005 0.5m1.0m5.0m9.0m

Price difference sensor, WT0120-A00-B00-C06-D10

Frequency response: 0-2KHz (-3dB) Sensitivity: 0.8V/mm, -2~-18V Output standard specimen material: 45 # steel or 42CrMO steel (AISI 4140) Linear range: 1.5mm~14mm Linear range: 12.5mm Nonlinear error:<1% Plane diameter (differential expansion DE measurement): φ 60mm Interchangeability error: Within a 5-meter or 9-meter system, the sensitivity error caused by the exchange of calibrated probes, extension cables, and preamplifiers of the same model is ± 2%. Ripple: ≤ 20mV, temperature drift: ≤ 0.05%/℃, preamplifier output impedance: 50 Ω, preamplifier to monitor on-site connection: allowed for 300 meters, electromagnetic compatibility: compliant with CE standards, isolation: ground insulation, installation safety approval: intrinsic safety Exia Ⅱ C T4, when used in hazardous areas, install intrinsic safety barriers.

Probe installation form 060711/"4-12M30 × 211/" -12 2M39 × 1.5 Non threaded side outlet Non threaded 1.06-inch diameter clamp outlet Non threaded 1.5in diameter clamp outlet B: Non threaded length 005250 metric thread probe, increasing by 5mm or 5mm units by 5mm250mm imperial thread probe, increasing by 0.1inch unit by 020 0.2in (standard specification) 880 8.8inC: Shell length 04525045mm250mm imperial thread probe, increasing by 0.1inch units by 160960 9.6-inch metric thread probe, increasing by 2mm or 5mm units for non threaded side outlet, shell length<45mmD: Total probe length 9005 0.5m1.0m5.0m9.0m1050E: Connectors and cables 0100 200 without connector, standard cable with coaxial locking connector, standard cable with other connectors and cable F: armored 0100 without armor, reverse mounted probe with stainless steel flexible armor G: Safety Approval 00 None 05 Intrinsic Safety Specification