Physical photo of monitoring device: HXW-U fuel tank oil level travel monitoring device

NegotiableUpdate on 02/16
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Physical photo of monitoring instrument: HXW-U oil tank oil level stroke monitoring instrument $r $n oil tank oil level stroke monitoring instrument HXW-U steam turbine needs to be equipped with a dedicated oil tank to continuously lubricate and conduct heat to its rotating parts during continuous high-speed rotation. Therefore, it is necessary to use an oil tank oil level monitoring instrument, coupled with a linear displacement sensor to monitor the level of the oil tank. When the liquid level is below a certain value, lubricating oil needs to be added to maintain the operation of the steam turbine to prevent accidents
Product Details

Fuel tank oil level travel monitoring instrument HXW-U

When the steam turbine rotates continuously at high speed, it needs to be equipped with a dedicated oil tank to continuously lubricate and conduct heat to its rotating components. Therefore, it is necessary to use an oil tank level monitoring device and connect it to a linear displacement sensor to monitor the liquid level in the oil tank. When the liquid level drops below a certain value, lubricating oil needs to be added to maintain the operation of the steam turbine to prevent accidents.

Function Description (Intelligent Type)

1. Realize intelligent processing: Alarm values I and II can be set arbitrarily through panel buttons

2. The panel buttons can adjust the range value without the need for potentiometer adjustment, making it convenient for on-site debugging

3. If you don't press the operation key for one minute, you can return to the running state by yourself

4. The alarm delay adjustment range is 0.1~3 seconds to prevent false alarms caused by on-site interference

5. Equipped with power up and power down detection functions, while cutting off alarm and shutdown output circuits, it can effectively suppress instrument false alarms

6. There is a current output terminal on the rear panel that is proportional to the oil level value of the fuel tank, for recording output

Physical photo of monitoring device: HXW-U fuel tank oil level travel monitoring device

Used for measuring and indicating the oil level in the turbine oil tank,It can also be used for measuring other liquid levels. When the steam turbine rotates continuously at high speed, it needs to be equipped with a dedicated oil tank to continuously lubricate and conduct heat to its rotating components. Therefore, it is necessary to use an oil tank level monitoring device, coupled with an oil tank level sensor, to monitor the level of the oil tank. When the level is below a certain value, lubricating oil needs to be added to maintain the operation of the steam turbine to prevent accidents.
Physical photos of the monitoring device

Main functions
Monitoring and protection of oil level in oil tanks of rotating machinery such as steam turbines, water turbines, compressors, and blowers.
Function Description:
1. display function
Oil level measurement value of fuel tankValue alarmThe alarm setting values can be set separately atLEDOn the digital display,4The digital display shows the symbol bit.

2.

alarm function
There are two levels of reporting that allow users to set alarm values as needed,When the oil level in the fuel tank exceeds the alarm set value, the corresponding alarm indicator light on the front panel will light up, and the monitoring instrument will output a switch signal on the rear panel to protect the controlled equipment.

3.

Alarm delay time setting function
Adjustment range of alarm delay time03Second, to prevent on-site interference from causing false alarms.

4.

Self diagnostic function
Equipped with power on and power off detection functions, while cutting off alarm and shutdown output circuits, it can effectively suppress false alarms of instruments.

5.

Record output
provided that420mACurrent output interface, compatible with computersDCSThePLCsystem,Connect devices such as paperless recorders.
Technical Specifications:
11. Input signal:UT81Type fuel tank oil level sensor output signal

2.

Display mode:4Bit digital display, bit as symbol bit, accuracy:±0.5

3.

Measurement range:-400400mm
4. Current output:420mAor010mA, load≤500Ω

5.

Alarm contact capacity:AC220V/3ADC28V/3A

6.

working environment:Temperature:055℃ relative humidity≤95%

7.

Working power supply: AC220VAC±10% 50Hzpower consumption≤10W

8.

Installation method:disc type

9.

Overall dimensions:160(Width)×80(High)×250(Deep)mm

10.

Opening size:152(Width)×75(High)mm