E-mail
3241984301@qq.com
-
Phone
15312954526
-
Address
No. 79 Chongchuan Road, Chongchuan District, Nantong City, Jiangsu Province
Jiangsu Qiucheng Electromechanical Co., Ltd
3241984301@qq.com
15312954526
No. 79 Chongchuan Road, Chongchuan District, Nantong City, Jiangsu Province
Based on the technical knowledge of German engineering, successful system developers, and experienced experts - MAXIMATOR GmbH is a supplier of high-pressure, testing, hydraulic, and pneumatic systems.Qualified and proactive company members are developing, designing, manufacturing, and internationally marketing products for use in process technology factories.
MPLV 2
MAXIMATOR has sales offices in Germany and partner companies around the world. As experts in high-pressure and testing technology, hydraulic and pneumatic fields, MAXIMATOR can provide services to our customers, ensuring immediate provision of customized solutions.In terms of pioneering technology, MAXIMATOR utilizes innovative new developments to provide our customers with effective and environmentally friendly solutions in their business areas.
| 3110.0185 TYPE M11112 |
| 3110.0186 TYPE M189 |
| VP16.03.123 NR:3630.0791 |
| OR75.33.02.03 Nr. 3660.0650 |
| 3630.0104 |
| 3610.1457 |
| seal kits for DLE5-2 German imported Maximator high-pressure pump 3640.0112 German imported Maximator high-pressure pump 3640.0112 |
| seal kits for DLE2-2 |
| seal kits for DLE30-2 |
| MPLV4 S-NR:474790 |
MAXIMATOR develops, designs, and produces all products from components to complex systems and even entire infrastructure.In addition to high-pressure pumps, high-pressure compressors, valves, hydraulic devices, and gas compressor stations, our service scope also includes self tightening systems, pulse test benches, gas and water injection systems, and hydrogen compressor systems.This product portfolio is supplemented and expanded by hydrogenation and hydrogen component testing systems.
The compact and low-cost MAXIMATOR high-pressure pump is driven by air or inert gas pressure ranging from 1 bar to 10 bar.MAXIMATOR pumps have numerous potential applications in mechanical engineering, oil and gas industries, chemical and pharmaceutical industries, defense, mining and construction industries, as well as aviation and aerospace.
The MAXIMATOR air drive concept provides you with many benefits:
| 3110.0186 TYPE M189 |
| 3110.0185 TYPE M11112 |
| S 25 D |
| S 25 D |
| GPLV 5 |
| VP16.02.01.02 Art. Nr. 3630.0708 |
| MGL60 Collar |
| MGL60 Gland |
| 65N6H-4-316 |
| GPLV 5 |
| Typ S 35 D-05 |
| M037 |
| VP16.03.123 NR:3630.0791 |
| OR75.33.02.03 Nr. 3660.0650 |
| 3630.0104 |
| 3610.1457 |
| S25D-D5 |
| S100D-D5 |
| Type S35-05-215/Item No. 3130.0104 |
| Type SPLV 3 Art. No. 3220.0348 |
| S35D |
MAXIMATOR provides professional consulting, engineering design, and complete system supply to optimize and economically solve your testing tasks, and offers you a wide range of services.
MAXIMATOR pumps come in 5 sizes to choose from: M, S, G, GX, DPD.The size varies depending on its applicability to different pumping media, wide range of flow rates, and maximum allowable working pressure.MAXIMATOR provides fluid pumps for every application.
| Operating Instructions - Pump-en-2016.fdf | |
|
|
In principle, MAXIMATOR pumps can be installed in any position, but the longest service life of seals is achieved in vertical pumps.
Port size is important!
Please note that only screws and pipes suitable for the pump pressure range have been installed.To ensure the operation of the pump (pressure and flow), the port size of the pump should not be reduced.
The pneumatic connection is located on the slide valve housing.As the second air drive connection of the non regulating pilot port on the S... D and G (SF) series, it must also be connected, not only to provide better pressure control, but also to be an ideal location for installing control instruments due to its small size.In any case, compressed air filters and water separators must be installed on the pump.The filter is equipped with a water separator, pressure regulator, control pressure gauge, and shut-off valve, which can be selected under "Air Control Unit C..." depending on the pump pipeline.
Due to the treatment with barium grease, the pump does not require an air lubricator.I have already used the lubricator once and strongly recommend continuing to use it.If only very dry air is available, an air lubricator is needed.
Usually between -20 ° C and+80 ° C (standard).The pump with the - VE sealed version can operate up to.+60 ° C, reaching up to+80 ° C in the short term is acceptable.For outdoor services at temperatures of 0 ° C and below, special versions can be provided upon request.
The normal operation and efficiency of a pump mainly depend on the quality of the hydraulic fluid used.We recommend using hydraulic oil with a viscosity between 46-68 cst, which is manufacturer hydraulic oil that complies with DIN 51524 T2;DIN 51519;ISO VG 46
| 3920.3816 | |||||||||||||||||||
| 3920.1422 | |||||||||||||||||||
| 3920.4700 L=3m | |||||||||||||||||||
| SPLV3 | |||||||||||||||||||
| Article No 3130.0198; Type S 35-05 | |||||||||||||||||||
| S35-05-215,313001,new type:35-NLR rt. Nr. 3130.0104 | |||||||||||||||||||
| SPLV3 | |||||||||||||||||||
| S60D-05 | |||||||||||||||||||
| S35D-05 | |||||||||||||||||||
| S25D-05 | |||||||||||||||||||
| S25-05 | |||||||||||||||||||
| S60-02 | |||||||||||||||||||
| MO 8 Nr:3120.0362 | |||||||||||||||||||
| S60-02 | |||||||||||||||||||
| 3640.0112 MAXIMATOR valves, fittings, and pipelines are suitable for different media and working pressures up to 10500 bar. Germany
MAXIMATOR valve accessory pipe | |||||||||||||||||||
| 3630.0903 | |||||||||||||||||||
| 3610.0636 | |||||||||||||||||||
| 3640.01 | |||||||||||||||||||
| 3640.0119 |