-
E-mail
139@qq.com
-
Phone
15956085358
-
Address
Tianchang
Anhui Yaokang Automation Instrument Co., Ltd
139@qq.com
15956085358
Tianchang
Product Category
1、 Zirconia analyzer model
-CY-2C-ISG-1000: Direct insertion type, insertion depth 1000mm, flange downward installation, K-type probe, range 0-25% or 0-20.6%, output 4-20mA.
-CE-2C-ISG-C-SW: Split type, equipped with dedicated cables, may be anti-corrosion or constant temperature type, with a range covering 0-700 ℃ (wall mounted) or higher temperatures.
-CE-2C-SW: Wall mounted, LED/LCD display, constant temperature type (0-700 ℃), output 4-20mA, supports PLC/DCS communication.
-Other models: ISG-C series (such as ISG-C-800/1000/1200), ISG-C-F anti-corrosion type, explosion-proof type MKFB-400-A/H, etc., covering disc mounted, vertical, high temperature type (0-1400 ℃), etc.

2、 Core components and specifications
-Probe and protective tube:
-The diameter of the zirconia probe is 45-47mm, and the protective tube material can be selected from stainless steel 304/316/316L, silicon carbide (SiC), GH3030/GH3039 alloy, etc.
-Flange specifications: outer diameter 155mm, aperture 130mm, matching short circuit 76mm, attention should be paid to welding sealing.
-Technical parameters:
-Range: 0-25% O ₂, 0-20.6% O ₂; The temperature range is 0-700 ℃ (constant temperature type) and 0-1400 ℃ (high temperature type).
-Output signal: 4-20mA, RS485/RS232, supports PID control, power supply of 220VAC/150W, explosion-proof grade EXdIICT6 (probe diameter φ 51mm).
3、 Application field classification
-Standard environment: Thermal power plant (standard type).
-Anti corrosion requirements: biomass power plants, waste to energy plants (anti-corrosion type); Hazardous waste treatment (high anti-corrosion type).
-High temperature scenario: Steel plant (high temperature type, 0-1400 ℃).
-Explosion proof scenario: Chemical plant (explosion-proof type, such as MKFB-400-A/H).
4、 Installation and structural type
-Installation methods: flange installation (DN50/DN80/DN100), wall mounted (such as CE-2C-SW), split type (special cable connection).
-Structural types: direct insertion (including high and low temperature types), suction type, disc mounted type, vertical type, some models support LED/LCD display.
Company and Product Introduction
-Company Information: Located in Tianchang Economic Development Zone, Anhui Province, we specialize in producing gas analyzers, temperature/pressure instruments, etc.
-Product line: Zirconia analyzer (split/integrated), electrochemical oxygen analyzer, explosion-proof analyzer, output signal compatible with industrial control systems (PLC/DCS), accuracy up to 0.01%.