1.Electric motors are specially designed and manufacturedThe highest efficiency, able to operate normally in high-pressure, desert like environments.
The action of tightening the belt is very simple, just loosen the bolt in the direction of the air inlet, and the other parts do not need to be disassembled.
3. Six blade design for wind power effect. The rotating system is specially designed and does not require refueling.
4. The shape of the blades ensures that only low noise is produced when generating air flow force.
The biggest feature of EOS fans is their louver opening and closing system (design), which does not use power or rotational force, but instead utilizes weight balance. This system can guarantee years of operation without any problems.
High pressure particle suction fan High pressure fan 5.5KW
Key points of construction and installation
1. The installation pedestal (foundation, hanger) should have sufficient strength, stability, and durability, and the vibration of the pedestal should meet the following requirements:
1) The natural frequency of the basic device shall not exceed one-third of the motor and speed;
2) The difference between the vibration speed during operation and the vibration speed at rest should be greater than three times.
2. Flexible joints should be installed between the inlet and outlet and the air duct. The inlet and outlet ducts and other devices should be separately supported and firmly supported by foundations or other building components. The casing should not bear the weight of other components.


When installed on building components, vibration isolation measures should be taken.
4. Installation can refer to the following national building standard design drawings.
Operation precautions
If the flow rate is found to be too high, does not meet the usage requirements, or requires a smaller flow rate in a short period of time, a throttling device can be used for adjustment.
2. Regularly check the sensitivity of thermometers and oil gauges, and control the oil level in the bearing box within the specified allowable range.
3. If any abnormal phenomena are found during driving, parking or operation, immediate inspection should be carried out.
4. For minor faults discovered during inspection, the cause should be promptly identified and efforts should be made to eliminate or handle them. If minor faults cannot be eliminated or major faults are discovered, immediate inspection should be carried out.