High and low temperature industrial circulation magnetic pumpIntroduction:
It mainly consists of a compressor, condenser, internal storage tank, container, and external pipeline. Temperature regulation is carried out through the internal storage tank. During operation, the internal medium is repeatedly subjected to low and high temperature cycles with an accuracy of up to 0.1 ℃ under the control of the set temperature machine. In addition, high and low temperature circulation pumps are also suitable for regulation within the conventional temperature range, as well as applications in industrial processes and other fields.
Features:
(1) Due to the fact that the drive shaft does not need to pass through the pump casing, but instead uses a magnetic field to transmit torque through the air gap and the thin wall of the isolation sleeve
By moving the inner rotor, the leakage channel of the shaft seal is fundamentally eliminated, achieving * sealing.
(2) There is overload protection when transmitting power.
(3) Except for the high requirements for magnetic materials and magnetic circuits, the technical requirements for other parts are relatively low.
(4) The maintenance and overhaul workload of magnetic pumps is relatively small.




High and low temperature industrial circulation magnetic pumpInstallation and maintenance:
1. Prepare the concrete foundation according to the basic dimensions and embed the anchor bolts accordingly;
2. Before installation, the pump and motor should be inspected, and all parts should be undamaged. There should be no debris inside the pump;
3. Place the unit on the foundation and place a pair of wedge pads between the bottom plate and the foundation. Adjust the wedge pads to align the level of the pump. After adjustment, tighten the anchor bolts;
4. The suction and discharge pipelines of the pump are supported by additional brackets;
5. After installation, turn the coupling by hand to check for any rubbing or friction. If the rotation is easy and even without any movement, the installation is complete;
6. To prevent debris from entering the pump, a filter should be installed at the inlet with a filtration area 3-4 times larger than the cross-sectional area of the pipeline;
7. Pumps with high head should also be equipped with check valves on the outlet pipeline to prevent water hammer damage caused by sudden shutdown;
8. It is necessary to ensure that the installation height of the pump meets the cavitation allowance of the pump, and consider pipeline losses and medium temperature.
Usage characteristics:
1. The equipment is mainly used in laboratories and requires high noise control during pump operation; We fix the impeller of the vortex pump on the axis to reduce pump noise;
2. All models of high and low temperature dedicated leak free magnetic pumps can be customized with explosion-proof, variable frequency, explosion-proof+variable frequency special pumps, and special voltages;
3. Compared to others, Orank has more obvious price and service advantages;
4. Compared to domestic brands, Orank Pump Industry has more obvious material configurations, higher quality detail requirements, and better service;
5. The axis of the high and low temperature dedicated leak free magnetic pump is made of pressureless sintered silicon carbide, which has better wear resistance and strength;
6. All flange configurations can be equipped with welding flanges and pipe flange options;