Burkert high-precision corrosion-resistant pH meterfeature
High precision: The Burkert pH meter uses electrode and circuit processing technology to achieve accurate measurement of pH value, with high precision and stability.
Multiple types: Provide multiple types of pH meters to meet the needs of different application scenarios. These pH meters can measure pH values in different ranges and have varying levels of accuracy and response time.
Easy to operate: Burkert pH meters typically have an intuitive user interface and simple operating procedures, allowing users to easily measure and set up.
Strong corrosion resistance: The electrode and sensor parts are made of corrosion-resistant materials, suitable for measuring various corrosive media.
Data recording and transmission: Some models of Burkert PH meters also have data recording function, which can record measurement data in real time and support data export and transmission, making it convenient for users to analyze and process data.
To ensure the long-term stable operation and measurement accuracy of Burkert PH meter, it is recommended to perform the following maintenance and upkeep work regularly:
Clean the electrode: Regularly clean the dirt and impurities on the surface of the electrode to prevent electrode contamination and performance degradation. Special electrode cleaning agents or distilled water can be used for cleaning.
Calibration: Regularly calibrate the pH meter to ensure the accuracy and reliability of its measurement results. Calibration can be performed using specialized calibration solutions.
Check the electrodes: Regularly check the wear and aging of the electrodes. If there is wear or aging of the electrodes, they should be replaced with new ones in a timely manner.
Storage: When not in use, the pH meter should be stored in a dry, ventilated, and non corrosive gas environment to avoid moisture or damage to the sensor.
regular maintenance
Clean electrodeRinse the glass film with deionized water every week to avoid contamination (such as protein or oil deposition).
Calibration verificationVerify accuracy monthly using standard buffer solution and recalibrate if necessary.
Replace the reference electrolyteAccording to the frequency of use, replace the reference electrode filling solution every 6-12 months.
Common faults and their solutions
Slow responseClean the glass film or replace the aging electrode.
Reading driftCheck if the reference electrode is poisoned, replace the filling solution or electrode.
signal interruptionCheck cable connections and power supply to eliminate electromagnetic interference.