E-mail
xiaoshou@kaiteer17.com
-
Phone
18962694961
-
Address
No. 16 Xingwu Road, Wuzhong District, Suzhou City, Jiangsu Province
Suzhou Kaitel Instrument Equipment Co., Ltd
xiaoshou@kaiteer17.com
18962694961
No. 16 Xingwu Road, Wuzhong District, Suzhou City, Jiangsu Province
K-R18380B touch screen controlSingle wire and cable vertical combustion tester(Customers can choose temperature measuring devices according to their needs)
Design according to test standards such as GB/T18380.1, GB18380.11, GB18380.12, IEC60332-1, JB/T 4278.5, BS, EN, etc. Suitable for inspecting and evaluating the combustion characteristics of single insulated cables and optical cables. The two ends of the sample are fixed and vertically placed in a metal cover with metal plates on three sides. Ignite the blowtorch to make the end of the blue inner coneTouch the test surface and maintain the nozzle perpendicular to the axis of the specimen at 45 degrees˚This device has a sophisticated design and is resistant to smoke corrosion. The key components are imported, with digital display time and automatic control of the test program, making them easy to use, stable and reliable.
Reference standards:
GB/T 18380.1-2001
GB/T 18380.11-2008
GB/T 18380.12-2008
GB/T 5169.14-2007
IEC60332—2004
JB/T 4278.5-2011
MT 818.1-2009
MT 386-2011
GB/T 19666-2019
K-R18380B touch screen controlSingle wire and cable vertical combustion testerMain parameters
1. The control box, fume hood, and metal cover are all integrated stainless steel structures;
The outer box is made of mirror stainless steel and has a door on the front that can be opened,
The top is equipped with smoke exhaust system and lighting.
2. Metal cover dimensions: height * width * depth: 1200 * 300mm * 450mm,
The front is open, and the top and bottom are closed.
3. The flame burning time can be set arbitrarily between 0.1-999.9 seconds;
When the combustion time reaches the set value, the gas will be automatically turned off;
4. Dual flow meters: Gas 0.1-1L/min, air 1.5-15L/min
5. Dual pressure gauges: one gas pressure gauge and one air pressure gauge each
6. Standard power of combustion blowtorch: 1KW,
7. Ignition method: automatic high-voltage ignition
8. PLC touch screen control: start, stop, lighting, exhaust, ignition time, combustion time,
After clicking start, the combustion test will be automatically conducted.
9. Gas: high-purity propane gas or temporary liquefied petroleum gas (to be provided by the user) is used
10. Rated voltage: AC220V/50Hz
K-R18380B touch screen controlSingle wire and cable vertical combustion testerThe parameters of the temperature measuring device are as follows(optional)
1.304 stainless steel bracket, adjustable height;
2. Flame monitoring device:
One imported K-type thermocouple with a diameter of 0.5mm from the United States,
A precision thermometer in Taiwan, China, China,
Electrolytic copper block with a diameter of 9mm and a mass of 10g ± 0.05g per piece.