K-LYB2099 plug and socket six group swing testing machine(Wire bending testing machine)
1Plug and socket six group swing testing machineIntroduction of
Comply with the provisions of relevant standards such as GB/T2099, UL817, VDE, etc., which stipulate the general requirements for flexible cord components and power cords. Suitable for manufacturers and quality inspection departments to conduct bending tests on power cords and DC cords.This machine is specifically designed to test the flexural strength of DC cables, headphone cables, USB cables, plug leads, and wires. The method is to fix the sample on a fixture and apply a certain load. During the test, the fixture swings left and right, and after a certain number of times, the breakage rate is checked; Or when it cannot be powered on, check the total number of swings. This machine can automatically count and stop the operation when the sample is bent until it breaks and cannot be powered on.
IIPlug and socket six group swing testing machineMain technical parameters
1. Fixtures: 6 sets (6 plug lead tests can be conducted simultaneously each time)
2. Swing angle: adjustable from 10 ° to 180 ° back and forth
3. Swing speed: 10~60 times/min adjustable
4. Automatic counters: 6, each independently counting
5. Load capacity: six pieces each of 50g, 100g, 200g, 300g, 500g, for a total of 30 pieces.
6. Dimensions (approximately): 85 × 60 × 75cm
7. Working power supply: AC 220V/50Hz
8. Weight approximately: 100KG
IIIPlug and socket six group swing testing machineInstructions for use
1. Before using this device, please read the instruction manual carefully to avoid any losses caused by improper operation.
2. This device should be handled with care after being shipped to your company, and there is a spacious storage space available. Check the screws and fasteners for any looseness during transportation before use.
3. Professional operators should be assigned to operate this equipment during use, and non professional operators should maintain a certain distance from the equipment.
4. The power supply used for the equipment is AC220V, and the ground wire must be grounded. The voltage inside the chassis is 220V. Do not open the back door of the chassis at will.
5. The machine should be cleaned once every month after use and lubricating oil should be added to the lubrication area.
4Plug and socket six group swing testing machinePrecautions for use
1. Lay the device flat on the ground
2. Keep the equipment dry and clean
3. Add lubricating oil to the mechanical motion area
4. After the experiment is stopped, the power should be unplugged