Monitoring of precision load distribution cabinetOverview
With the rapid development of data centers, the energy consumption problem of data centers has become increasingly prominent. Regarding energy management and power supply and distribution design of data centersAn efficient and reliable data center power distribution system solution has become a hot topic, which can improve the efficiency of data center power utilization and reduce equipment energy consumptionEffective methods. To achieve energy conservation in data centers, it is first necessary to monitor each electrical load, and there are many load circuits in data centers. Traditional measurement methodsThe instrument cannot meet the requirements of cost, volume, installation, construction, and other aspects, so it is necessary to adopt a multi loop system suitable for centralized monitoring in data centersRoad monitoring device.
It is a measuring device specifically designed for power management of data center servers. thatThe device is designed to be compact and capable of real-time monitoring of all electrical parameters, input and output switches, and lightning arrester status for both A+B incoming lines and 192 outgoing linesThe alarm threshold of the measurement channel can be set separately, and the out of limit event immediately triggers the system's sound and light alarm, realizing the monitoring circuit in the volume of traditional instrumentsHighly integrated.
2 Product Model

3 Technical Specifications
AMC100-FD48direct currentPrecision distribution cabinet monitoringdeviceDC output line


Note: The secondary input voltage of the DC input and output modules is 5VThe default value of the primary side current is100AIf the Hall sensors are different, customers can set the ratio through the touch screen according to their actual usage.
4. External structure
AMC100 Series DCPrecision distribution monitoring device
AMC100-ZD、AMC100-FD □48、 AMC100-K □48、 AMC100-FT48

Monitoring of precision load distribution cabinetfunction
Real time monitoring and visualization
Display electrical parameters and environmental status in the form of dashboards, curves, heat maps, etc., supporting multi-level drilling (such as from the main cabinet to branch circuits).
3D visualization technology can restore the internal structure of the distribution cabinet and intuitively locate the fault point.
Intelligent alarm and warning
Set threshold alarms (such as overvoltage, undervoltage, overload, temperature exceeding limit), support multi-channel notifications such as SMS, email, APP push, etc.
Based on historical data and AI algorithms, predict equipment degradation trends (such as contactor contact wear and cable insulation aging) and arrange maintenance in advance.
Energy Efficiency Management and Optimization
Analyze the energy consumption ratio of different circuits and equipment, identify high energy consuming links, and provide energy-saving suggestions (such as adjusting load distribution and phasing out old equipment).
Support peak valley flat electricity pricing strategy, automatically optimize equipment start stop time to reduce electricity costs.