Product manual

product specification

Brief introduction
The working principle of a micro differential pressure transmitter is that the pressure of the medium directly acts on the diaphragm of the sensor, causing the diaphragm to produce a micro displacement proportional to the pressure of the medium, resulting in a change in the resistance of the sensor. The electronic circuit is used to detect this change and convert it into a standard signal corresponding to this pressure.
This product uses imported integrated chips, wide voltage power supply, strong anti-interference ability, reverse connection protection, high accuracy, good stability, and can artificially correct zero points.
Micro differential pressure transmitter obtains the pressure difference between air and non corrosive gases, and is suitable for various industrial automation environments such as HVAC, dust-free clean rooms, pipeline air supply, boiler negative pressure, oven pressurization, ventilation equipment, fan control, variable air volume systems, etc.
2、 Product Device Introduction

3、 Model and Description

4、 Wiring method

5、 Product Features
1. Linear pressure characteristics and selectable pressure measurement range
2. Working voltage: 16-30VDC
3. Signal output: 4-20mA/0-5V/0-10V/RS485 type
4. Zero point adjustment
5. Simple and fast installation brought by the integrated bracket inside the shell
6. Calibration and temperature compensation measurement signals
6、 Application areas:
1. Measure subtle pressure differences in ventilation equipment and air conditioning ducts
2. Check the air flow rate
3. Monitor filters and control fans
7、 Model Summary
Unit: Pa
|
Product series |
product name |
Pressure range measurement |
|||||
|
Measurement Range 1 |
Measurement range 2 |
Measurement range 3 |
Measurement range 4 |
Overload pressure |
Impact Pressure |
||
|
BPS-01 |
100Pa micro differential pressure transmitter |
±50Pa |
- |
±65Pa |
±100Pa |
±10Kpa |
±20Kpa |
|
BPS-02 |
1KPa micro differential pressure transmitter |
±250Pa |
- |
±500Pa |
±1Kpa |
±10Kpa |
±20Kpa |
|
BPS-03 |
10KPa micro differential pressure transmitter |
±2KPa |
±3KPa |
±5KPa |
±10KPa |
±85Kpa |
±110Kpa |
|
BPS-04 |
35Kpa micro differential pressure transmitter |
±30KPa |
±35KPa |
- |
- |
±175Kpa |
±280Kpa |
8、 Operation mode
The sensor obtains the pressure difference value through silicon piezoresistive elements, and the sensor forms a linear 4-20mA/0-5V/0-10V/RS485 temperature compensation output signal based on the sensed deviation value.
9、 Mechanical Design
The micro differential pressure transmitter consists of the following components:
1. Sensor housing fixed bracket, cable entry, movable buckle cover with safety screws
2. Force measurement uses silicon piezoresistive elements
3. Printed circuit board with wiring terminals and DIP switches for selecting measurement range ("see debugging precautions")
4. Zero point adjustment button ("see debugging precautions")
10、 Debugging precautions
Adjustable measurement range: pressure range and direction, adjusted by dip switch

Zero point adjustment: reset and calibration
Short press the zero adjustment button (within 1 second) to reset the panel.
(Please manually reset it while keeping it parallel to the installation method; please manually reset it while the positive and negative air intakes are connected.)
|
Operation steps |
state |
result |
key |
|
1. Power on PCB 2. Keep the positive and negative pressure inlet pressure difference at zero 3. Click the 0-point button |
Red light on |
0-point calibration |
|
11、 Technical parameters
Product Data:
|
measuring range |
Refer to "Model Summary" |
|
Sensing element |
Silicon piezoresistive element |
|
Room temperature |
Measurement during correct installation at 20-25 ℃ (FS=full range measurement) |
|
Accuracy: Total error Temperature offset |
± 1 % /± 0.5 % / ±0.2% FS <±0.1% FS /°C |
|
medium |
Air and non corrosive gases |
|
Allowable temperature range of the medium |
-20-85℃ |
|
maintenance |
long term stability |
Electrical characteristics:
|
All output types |
power supply |
safety extra low voltage |
|
voltage power consumption |
DC16-30V <1.5 VA |
|
|
4-20mA output type |
output current |
4-20 mA |
|
load |
≤250 Ω |
|
|
output |
Non electric separation, non-polar two-wire connection, rectifier bridge anti reverse connection |
Link:
|
Electrical connection |
|
|
screw terminal |
Maximum 1.5mm ² cable |
|
cable |
Cable sealing gland mouth (without anti cable deformation) |
|
Pressure connection |
Pressure nozzle, 6.21 mm diameter |
Environmental conditions:
|
Allowable ambient temperature |
|
|
run |
-20-85℃ |
|
Transportation/Storage |
-40-125 ℃ |
|
Allowable environmental humidity |
<90% RH (non condensing) |
12、 Appearance dimensions (length * width * height: 99.0 * 101.5 * 39.9mm, tolerance: ± 1mm)

13、 Installation method
|
|
First, use the back ruler to mark the installation hole position on the wall, drill a 30mm Ø 6mm wall hole to place the expansion tube, then open the buckle of the micro differential pressure transmitter and flip over the cover
Cover, fix the self tapping screw (ST3.5 × 25) in the designated position on the wall through the fixing hole of the micro differential pressure transmitter, connect the incoming and outgoing wires through the waterproof joint, and finally cover with the cover.
be careful:
No air duct connection device is provided during supply;
Please read the instruction manual carefully and follow the wiring diagram for operation. If the product is damaged due to wiring reasons, it cannot be covered by warranty.