Measuring fluids: saturated steam, superheated steam, gas, liquid (avoid multiphase flow)
Gas (including steam)±1.5%±0.5%
pipe sectionliquid±1.0%±0.33%
Gas (including steam)±1.0%±0.33%
plug-inliquid±2.5%±0.83%
gas±3%±1.0%
Gas (including steam)755 (DN ≥ 200 is 50)
liquid0.75.5
Rated pressure: GB 1.6MPa, 2.5MPa, 4.0MPa, 6.3MPa Medium temperature: ordinary full tube type: -40~250 ℃
DIN PN16、PN25、PN40 High temperature full tube type: -40~350 ℃
JIS 10K、20K、40K Ordinary plug-in type: -40~120 ℃
ANSI Class150、Class300、Class600 High temperature plug-in type: -40~250 ℃
Structure type: pipe segment vortex flow sensor, plug-in vortex flow sensor
Sensor body 304 stainless steel
bluff body 304 stainless steel
detection probe 316L stainless steel
connecting rod 304 stainless steel
heat sink aluminum alloy
shim High temperature resistant asbestos pad, rubber pad, graphite pad
The first power supply method is 24VDC power supply
The second power supply method is 3.6V lithium battery power supply (local display type)
The third power supply method is dual power supply of 24VDC and 3.6V lithium battery
Output signal: pulse output, 4-20mA current output, RS-485 (customizable) Body processing: The flowmeter body is made of stainless steel sandblasted, and the amplifier housing is sprayed with plastic
Protocol, Hart, RS-485 (ModBus protocol)
Electrical interface: M20 * 1.5 Environmental temperature: -35~60 ° C (without LCD), -5~60 ° C (with LCD)
Explosion proof grade: explosion-proof Exd IIBI T3~T6 Gb, intrinsic safety Exia IIC T4 Ga Relative humidity: 5~95%
Protection level: IP65