Water (20 ℃) 1~200000 1/h Air (20 *, 0.1013MPa) 0.03~4000 m '/h
Refer to the flow chart, special flow rates can be customized
P1:1.6Mpa(DN80-DN200) P2: 4.0Mpa(DN15-DN50)
P3:16Mpa(DN80-DN200) P4:25Mpa(DN15-DN50)
The pressure rating of the jacket is 1.6Mpa
Standard type (E): -80 ℃ to+110 ℃; PTFE standard: 0 ℃~85 ℃, with damping: 0 ℃~60 ℃, high temperature type (H): -80 ℃~+300 ℃
DN15:the <5mPa.s(KV15.1~KV15.3) the <30mPa.s(KV15.4~KV15.8)
DN25:the <250mPa.s DN50~DN150: the <300mPa. S
Remote transmission type: -40 ° C~+85 ° C (LCD will not be damaged), LCD works normally at -30 ° C~+80 ° C
Local pointer type: -40 ° C~+100 ° C Intrinsic safety and explosion-proof type: -30 ° C~+60 ° C
Standard Type: HG20592 Special type: User's standard flange
Standard type: 24VDC two-wire system 4-20mA Communication type: 85-265VAC 50HZ
Battery type: 3.6V@7.5AH Lithium battery, with a continuous service life of more than three years
Upper or lower limit instantaneous flow alarm Open collector output: large 100mA@30VDC Impedance of 100 ohms
Relay output: Contact capacity: 1A@30VDC or 0.25A@250VAC Or 0 5A@125VAC