Measurement cycle: 500ms (2 times per second, 128 sets of data collected per cycle)Measurement principle: Ultrasonic time difference principle, 4-byte IEEE754 floating-point operation
Input: 3-channel 4-20mA input optional, with an accuracy of 0.1%, can input signals such as pressure, liquid level, temperature, etc
2-channel three wire Pt100 platinum resistor input circuit, capable of achieving heat metering function (enthalpy difference method)
Output: 1 isolated RS-485 output
1 channel 4-20mA or 0-20mA output
1-channel isolated OCT output (adjustable pulse width 6-1000ms, default 200ms)
1 relay output (pulse width 200ms)
External binding type: standard 861 type, suitable for pipe diameter DN15-100
Standard 862 type, suitable for pipe diameter DN50-700
Standard 863 type, suitable for pipe diameters of DN300-6000
High temperature 891 type, suitable for pipe diameter DN15-100
High temperature 892 type, suitable for pipe diameter DN50-700
Insertion type: standard 871 type, cement pipe 872 type: suitable for pipe diameter DN>80
Signal cable: SEYV75-2 shielded twisted pair cable, factory standard 5-meter, single cable can be extended up to 500 meters in specific occasions (not recommended)
Protection level: IP68 (capable of working in water immersion)
Pipe materials: steel, stainless steel PVC、 Copper, aluminum, cement pipes, and all other materials are dense pipes that allow for lining
Lining materials: epoxy asphalt, rubber, mortar, polypropylene, polystyrene, polyester, polyethylene, hard rubber, polytetrafluoroethylene
Inner diameter: 15~6000mm
Straight pipe length: upstream ≥ 10D, downstream ≥ 5D, distance from pump outlet ≥ 30D
Types of tested media: water, seawater, acidic and alkaline liquids, food oil, crude oil, alcohol, beer, and other uniform liquids that can propagate ultrasonic waves
Turbidity:<20000ppm, good sewage measurement effect, most sewage pipelines can be stably measured
Temperature: Ordinary type 0~70 ℃, High temperature type 0~160 ℃
Flow direction: It can measure both forward and reverse flow separately, and can also measure net flow