1Intelligent temperature and humidity inspection instrumentOverview
The intelligent inspection instrument adopts advanced microcomputer technology and chips, with reliable performance and strong anti-interference ability. It can be used in conjunction with various temperature and humidity sensors and transmitters to perform cyclic detection, alarm control, transmission output, data acquisition and communication of multiple temperature and humidity process parameters. Using a single-chip microcomputer as the host reduces peripheral components and improves reliability. Integrate multiple input models and output methods into one machine. Adopting WATCHDOG circuit, software trap and redundancy, power down protection, digital filtering and other technologies, emphasizing on-site fault tolerance, the whole machine has strong anti-interference ability.
IIIntelligent temperature and humidity inspection instrumentMain technical indicators
Input signal:4-20mATemperature and humidity transmitter
Measurement accuracy: ±0.2%FSThe instrument automatically calibrates the time drift and temperature drift,Throughout the entire temperature range of use0~50℃)Ensure measurement accuracy for an extended period of time.
divide distinguish 力:1/20000、14bitA/Dconverter
Display mode: Double row four digitLEDDigital tube, upper row displays measurement values, lower row displays channel numbers
Sampling period0.5SEquipped with a communication instrument, it collects eight data streams per second.
Alarm output:The instrument can be equipped with up to 12 relay alarm outputs, 220V/3A.
Transmission output: corresponding channel band can be selected 4~20mA、0~10mA、1~5V、0~5V, Isolation output, accuracy: ±0.2%FS
Communication output: isolated communication interfaceRS485/RS232
Baud rate1200~9600bps internal free setting
Working environment: Temperature0~50℃humidity<85%RH
electricity Source: Switching power supply 85~265VACorDC24Vpower consumption4Wbelow
Overall dimensions:160×80×120mm(Plate mounted horizontal) 80×160×120mm(Plate mounted vertical)320×120×270mm(Desktop)
IIIFeatures
Universal input function
Automatic calibration and manual calibration functions
Multiple protection, isolation design, strong anti-interference ability, high reliability
A good software platform with secondary development capabilities to meet special functions
Advanced modular structure, combined with powerful instrument chips, makes it very convenient to combine functions and upgrade systems
Automatic inspection and manual scheduled inspection can be freely switched
4 Model Description
type score |
say bright |
||||||
FI-500 |
|
Intelligent inspection device |
|||||
outside form ruler inch |
A |
|
horizontal format160×80×125mmopening152×76 |
||||
T |
|
desktop320×120×250mm |
|||||
number of channels |
□ |
1-64The road,AThe most diverse range of specifications and instruments32road |
|||||
|
alarm output |
J1 |
|
Unified upper limit alarm for each channel |
||||
J2 |
|
Unified lower limit alarm for each channel |
|||||
J8 |
|
Each channel has independent alarms (the most numerous)8Road) |
|||||
transmitter output |
O1 |
|
4~20mAoutput |
||||
O2 |
|
0~10mAoutput |
|||||
O3 |
|
1~5V output |
|||||
O4 |
|
0~5V output |
|||||
communication output |
P |
|
Micro printer |
||||
R |
|
Serial communicationRS232 |
|||||
S |
|
Serial communicationRS485 |
|||||
power supply |
|
220VACpower supply |
|||||
W |
DC24Vpower supply |
||||||
5Operation Manual
(1) Panel Description
1-24: Alarm status indicator light for 1-24 channels
PV measurement value display window
SV Inspection Channel Display Window
(2) Key function
● - Backup key.
En- Parameter setting key,When setting the state, it is used to store the new set value of the parameter and select the next set parameter.
▲- Set value increase key,When setting the stateUsed to increase numerical values. When the output is displayed in the lower row, press this key to increase the output.
▼ - Set value increase key,When setting the stateUsed to reduce numerical values.When the output is displayed in the lower row, press this key to reduce the output amount.
■- Regular inspection/Inspection switch button, when in inspection mode, press this button,Stop at a certain channel for regular inspection,Press ▲ or▼ KeyCan change the regular inspection channel,Press this button again to enter automatic inspection. During regular inspection, the lower row displaysXt/Xr(What is the temperature measurement channel? Note:Xrepresent numbers1~9,tRepresenting temperature,rRepresenting humidity)During inspection, the lower row displays-XX-.