Overview
The integrated DC energy meter for heavy-duty truck charging stations is a product developed specifically for DC metering scenarios such as charging stations. It adopts an integrated design of splitter and energy meter, and has the characteristics of high metering accuracy, small size, convenient wiring, strong communication compatibility, and rich functions.
Product Details

Integrated DC energy meter for heavy-duty truck charging stationDJSF1352-D-600, is a product developed specifically for DC metering scenarios such as charging stations. It adopts an integrated design of a splitter and an energy meter, and has the characteristics of high metering accuracy, small size, convenient wiring, strong communication compatibility, and rich functions.

Measurement accuracy requirements

The measurement accuracy of low-power DC charging stations is directly related to the interests of consumers and the cost accounting of operators. According to relevant standards, such as JJG 1149-2022 "Verification Regulations for Off board Chargers of Electric Vehicles", the accuracy level of DC charging piles is divided into level 1 and level 2.

重卡充电桩一体式直流电能表

stability requirements

The stability of DC energy metering is crucial for long-term reliable billing. Low power DC charging stations may be affected by factors such as different environmental temperatures, humidity, and power grid fluctuations. To ensure stability, the charging station needs to be equipped with high-quality metering modules and have good temperature compensation and anti-interference capabilities. It can ensure metering stability within the environmental temperature range of -20 ℃ to+50 ℃, ensuring long-term stability and accurate billing.

Data recording and transmission requirements

To achieve refined operational management, low-power DC charging stations need to have complete data recording and transmission functions. In terms of data recording, it is necessary to record in detail the start time, end time, charging amount, charging cost, and other information of each charging. The operator can monitor the operation status and energy measurement of charging piles in real time through the platform, timely discover and handle problems, and improve operational efficiency and service quality.

Compatibility requirements with charging facilities

With the development of new energy vehicle technology, there are differences in the charging needs of different brands and models of vehicles, which requires good compatibility in the energy metering of low-power DC charging piles. On the one hand, the metering system should be able to adapt to different ranges of vehicle charging voltage and current changes. On the other hand, it needs to be compatible with different charging protocols.

Selection of electric energy metering for low-power DC charging piles

For low-power DC piles,DJSF1352-DtypeIntegrated DC energy meter for heavy-duty truck charging stationIt's an ideal choice.DJSF1352-DThe Type DC energy meter is a high-precision DC measuring instrument developed and produced by Ankerui Electric, which integrates a shunt and a measuring instrument, corresponding to a DC current of up to 600.

重卡充电桩一体式直流电能表


DJSF1352-D360Integrated energy meter with splitter

重卡充电桩一体式直流电能表

DJSF1352-D-600 Integrated DC Intelligent Energy Meter

Compact in size, easy to install

The DJSF1352-D series adopts a splitter integrated design, with a volume only 1/3~1/4 of traditional split type electric meters, suitable for compact charging station interior space, and adopts standard DIN35mm rail installation.

重卡充电桩一体式直流电能表

Installation dimensions of DJSF1352-D360 integrated DC measuring instrument (unit: mm)

重卡充电桩一体式直流电能表

Installation dimensions of DJSF1352-D600 integrated DC measuring instrument (unit: mm)

High precision and high reliability metrology

DJSF1352-D360 DC metering accuracy reaches Class B (1.0), with a wide operating temperature range (-40 ℃~+70 ℃), humidity ≤ 95% RH, and an average operating time of ≥ 50000 hours, suitable for complex outdoor environments.

Comprehensive functionality and strong compatibility

The DJSF1352-D300 DC metering instrument is equipped with multiple communication protocols such as Modbus RTU, DL/T 645-2007, DL/T698, etc. It can choose between one second pulse output and one electric energy pulse output. The voltage input range is DC 0-1000V, and the current input supports up to 300A. The data recording and transmission meet the requirements of relevant national standards and are compatible with the charging requirements of the vast majority of mainstream electric vehicles.


重卡充电桩一体式直流电能表

Figure DJSF1352-D300Integrated DC energy meterWiring Diagram

重卡充电桩一体式直流电能表


Diagram of wiring for DJSF1352-D360 shunt integrated energy meter



MID certified integrated energy meterDisplay module wiring

重卡充电桩一体式直流电能表

1*display module+1*DC energy meter

重卡充电桩一体式直流电能表

1*display module+2*DC energy meter