1 Overview
DTSD1352-4S seriesEthernet three-phase multi circuit energy meterMainly used for full electrical parameter measurement of multiple circuits, up to 4 three-phase circuits can be connected simultaneouslyThe current input of the circuit or 12 single-phase circuits. It can measure parameters such as voltage, current, power, power factor, phase angle, imbalance, harmonics, etc.
2 Product functions and technical parameters
2.1 Product Features
4 Road three-phase or12 Measurement of full electrical parameters for single-phase circuits, with external current transformers or Roche coils;
Monitor the voltage of each phase/Current, zero sequence current, frequency;
Monitor the power of each phase and total power (active, reactive, apparent);
Monitor the power factor of each phase and the total power factor;
Monitoring voltage/Current phase angle, voltage/Current imbalance;
Monitor the total harmonic wave of voltage and current2-31Subharmonic;
Record of extreme values of voltage, current, and power for the current month and the previous month;
Maximum current, maximum power demand, real-time current, and real-time power demand;
200 Event record, recordDIDOThe action situation;
Supports overvoltage, overcurrent, phase failureDILinkage and other alarm outputs;
4 time zone14 Rate setting for time periods;
Four quadrant electrical energy,12 Monthly compound rate electricity statistics;
31 Four quadrant and multi rate electricity freezing, forward and reverse energy metering;
① Four passive switch inputs, two active switch inputs, and one switch outputRS485Communication;
② Two passive switch inputs, two switch outputsRS485Communication;
③ Ethernet communication;
Note: Among them, ①②③ can only be selected from three options.
2.2 Ethernet three-phase multi circuit energy meterTechnical Specifications


3 matching current sensors
The current sensor is a crystal head interface, three in one, with optional secondary output current50mA/100mV/333mV(Please specify when placing an order). customerThe current ratio can be modified through the instrument interface or communication based on the actual sensor specifications installed. The sensors are shown in Figures 1 and 2.
The ratio calculation is as follows:When the sensor outputs secondary current20mAWhen, the sensor specification isxxx A/20 mA,CT=2.5*xxx;When the sensor outputs secondary current50mAWhen, the sensor specification isxxx A/50 mA,CT=xxx;When the sensor outputs secondary current100mVWhen, the sensor specification isxxx A/100 mV,CT=xxx;When the sensor outputs secondary current333mVWhen, the sensor specification isxxx A/333 mV,CT=xxx;When users choose to actually connect to the Roche coil, they need to configure the sensor type to be "Roche coil" themselves (request configuration software from the R&D department).

4. Dimensions and Installation Instructions
4.1 Dimensions (Unit: mm)


4.2 Wiring Instructions
The wiring terminal is shown in the following figure