ICB standard stamping pump

NegotiableUpdate on 05/16
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

ICB standard stamping pump

Product Details

ICB standard stamping pump

1ICB standard stamping pumpCharacteristics, principles, and images:

The ICB standard stamping pump (pipeline pump) can be widely used in industries such as petrochemicals, oils and fats, food, beverages, pharmaceuticals and hygiene, electricity, textiles, printing and dyeing, water treatment, environmental protection building water supply, boiler water supply, etc., to transport media with a temperature not exceeding 180 ℃.

IIICB standard stamping pumpTechnical conditions
1. Design pressure: 1.0MPa
2. The working temperature of ICB standard stamping pump is -40 ℃ -180 ℃
3. Mechanical sealing material static ring: (ceramic/silicon carbide, tungsten carbide)
4. Moving ring: (graphite/silicon carbide/tungsten carbide)
5. Sealing ring: (nitrile rubber/EPDM rubber/fluorine rubber/PTFE)

IIIICB standard stamping pumpModel Description:

4ICB standard stamping pumpTechnical parameters

Model number Impellerform of impeller Flow Capacity m3/h Head height (Headm) Speed Apeedrpm Efficiency% Efficiency Supporting motor power (kw) motorPower Cavitation allowance NPSHr (m)
lCB ICB(D)
ICB20-12-125 O 1.6 20 2900 47 0.37   3.5
ICB20-12-160 O 1.6 30 41 0.37   3.8
A 1.2 24 40 0.55  
ICB32-25-125 O 3.2 20 45 0.55   3.5
ICB32-25-160 O 32 30 40 0.9   3.8
A 2.5 24 39 0.75  
ICB50-25-125 O 6.3 20 61 1.5 1.5 2
A 5 15 60 1.1 1.1
lCB50-25-160 O 6.3 32 57 2.2 3 2
A 5 25 56 1.5 2.2
ICB50-25-200 O 6.3 50 49 4 5.5 2
A 5 40 48 3 4
ICB50-32-125 O 12.5 20 63 1.5 2.2 2
A 10 15 62 1.1 1.5
ICB50-32-160 O 12.5 32 58 2.2 3 2
A 10 25 57 1.5 2.2
ICB50-32-200 O 12.5 50 50 4 5.5 2
A 10 40 49 3 4
ICB65-50-125 O 25 20 72 22 3 2
A 20 15 71 1.5 2.2
ICB65-50-160 O 25 32 70 4 5.5 2
A 20 25 69 3 4
ICB65-40-200 O 25 50 64 7.5 7.5 2
A 20 40 63 5.5 7.5
lCB80-65-125 O 50 20 78 4 5.5 2
A 40 15 77 3 4
ICB80-65-160 O 50 32 75 7.5 7.5 2
A 40 25 74 5.5 7.5
ICB80-50-200 O 50 50 73 11 15 2
A 40 40 72 9 11
ICB100-80-125 O 100 20 76 9 11 2
A 80 15 75 7.5 7.5
Model number Impellerform of impeller Flow Capacity m3/h Head height (Headm) Speed Apeedrpm Efficiency% Efficiency Supporting motor power (kw) motorPower Cavitation allowance NPSHr (m)
ICB ICB(D)
ICB20-12-125 O 3.2 5   53 0.37 0.37  
A 2.5 4 51 0.37 0.37 1.7
ICB50-25-160 O 3.2 8 47 0.55 0.55  
A 2.5 62 43 0.37 0.37 1.7
ICB50-25-200 O 3.2 12.5 41 0.75 0.75  
A 2.5 10 39 0.55 0.55 1.7
ICB50-32-125 O 6.3 5 55 0.55 0.55  
A 5 4 53 0.37 0.37 1.7
ICB50-32-160 O 6.3 8 49 0.55 0.55  
A 5 62 45 0.55 0.55 1.7
ICB50-32-200 O 6.3 12.5 43 0.75 0.75  
A 5 10 41 0.55 0.55 1.7
ICB65-50-125 O 12.5 5 64 0.55 0.55  
A 10 4 58 0.55 0.55 1.7
ICB65-50-160 O 12.5 8 62 0.75 0.75  
A 10 6.2 60 0.55 0.55 1.7
ICB65-40-200 O 12.5 12.5 55 1.1 1.1  
A 10 10 54 0.75 0.75 1.7
ICB80-65-125 O 25 5 71 0.75 0.75  
A 20 4 67 0.55 0.55 2
ICB80-65-160 O 25 8 70 1.5 1.5  
A 20 6.2 64 1.1 1.1 2
ICB80-50-200 0 25 12.5 69 2.2 2.2  
A 20 10 62 1.5 1.5 2
ICB100-80-125 O 50 5 71 1.5 2.2  
A 40 4 68 1.1 1.5 2