E-mail
office55@silkroad24.com
-
Phone
18964582625
-
Address
Building 1034-1035, No. 999 Wangqiao Road, Chuansha, Pudong New Area
Xierko Trading (Shanghai) Co., Ltd
office55@silkroad24.com
18964582625
Building 1034-1035, No. 999 Wangqiao Road, Chuansha, Pudong New Area
The GSR 52 series direct acting solenoid valve can be started at zero pressure difference and is suitable for gas and liquid media. It is a direct acting two-way solenoid valve with optional brass or stainless steel valve body, suitable for gas and liquid media, featuring zero pressure starting, high lifespan, and IP65 protection. Featuring a compact structure, long lifespan, and reliable sealing, it is suitable for various industrial automation control applications.
GSR solenoid valve 52 series Xierke
GSR solenoid valve 52 series Xierke
Brand:GSR
Series:52
Product Name2/2-way direct acting solenoid valve
·.52
·This is the code for the product series, representing 52 series Direct acting solenoid valve.
·4
·This number represents the interface (connection) size of the valve. According to the table in the document, the corresponding relationship is as follows:
·3 = G 1/8
·4 = G 1/4
·5 = G 3/8
·6 = G 1/2
·In the example 4 represent G 1/4 inch threaded interface.
·1
·This number represents the material of the valve body (housing). According to the table in the document, the corresponding relationship is as follows:
·06 =Edelstahl 1.4301 (stainless steel 1.4301)
·08 =Edelstahl 1.4581 (stainless steel 1.4581)
·10 =Messing 2.0402 (brass 2.0402)
·Attention: In the document Housing The code in one column is a two digit number, but in the order number, it follows the interface size as a whole. For example,41 express G 1/4 interface+brass valve body.
·0
·2
·These two digits represent the sealing components of the valve(O-ring and other materials. According to the table in the document, the corresponding relationship is as follows:
·02 =FKM (fluororubber, high temperature resistance, good oil resistance)
·04 =PTFE (polytetrafluoroethylene, chemically inert)
·06 =EPDM (ethylene propylene diene monomer rubber, water-resistant and ozone resistant)
·In the example 02 The representative sealing material is FKM。
·/
·slash / It is a delimiter.
·-NO (Optional)
·This is an optional suffix used to specify the function of the valve.
·Not labeled: indicates NC (Normal Closed), which means the valve closes when there is no power.
·-NO: indicates NO (Normal Open), which means the valve opens when there is no power.
·Attention: In the documentIn the "ABMESSUNGEN" (size) table, the model of the NO type valve is clearly marked with-NO suffix.
·1
·8
·2
·These three digits represent the model of the electromagnetic coil, which determines the voltage, power, and protection level of the coil. According to the table in the document, the corresponding relationship is as follows:
·182 = 10,5 VA / 6,8 W, Standard IP65
·032 = 15 VA / 11 W, Standard IP65
·012 =
24 VA / 18,5 W, Standard IP65*178 = 5,3 VA / 5,2 W, Standard IP65*148 = 8,5 VA / 10 W, Standard IP65*03 =15 VA/11 W, ATEX (explosion-proof type)*17 =5,3 VA/5,2 W, ATEX (explosion-proof type)*14 =8.5 VA/10 W, ATEX (Explosion proof)*In the example 182 Representing a power of 6.8 watt standard coil with a protection level of IP65. * Attention: If necessary ATEX explosion-proof certification should be selected03,17,14 Waiting for the code.
·/
·slash / It's a delimiter.
·-xx (Optional)
·This is an optional suffix used to specify some special features or configurations. According to the table in the document, the corresponding relationship is as follows:
·NO =Stromlos ge ö ffnet (normally open - but commonly used)-NO more direct)
·O =Sauerstoff (Oxygen Application - Special Cleaning and Treatment of Valves)
·OF =Gereinigt (cleaning treatment)
·HA =Handnotbet ä tigung (manual emergency operation device - can manually open and close the valve in case of power failure)
·For example,.5241/10-02/182/HA This valve is equipped with manual emergency operation function.