Flow Mo Flow Meter Small Series by Xierke

NegotiableUpdate on 02/21
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The Small Series is a robust, highly versatile, and extremely reliable traffic monitoring device designed for use in the most demanding environments. It provides continuous local flow monitoring through mechanical pointers, switches, transmitters, or digital flow/total quantity displays. This series can be made of various materials and is suitable for a wide range of liquid, air, and gas applications. $r $nFlow Mon Flow Meter Small Series Series by Xierko
Product Details

The Small Series is a robust, highly versatile, and extremely reliable traffic monitoring device designed for use in the most demanding environments. It provides continuous local flow monitoring through mechanical pointers, switches, transmitters, or digital flow/total quantity displays. This series can be made of various materials and is suitable for a wide range of liquid, air, and gas applications.


Flow Mo Flow Meter Small Series by Xierke

Flow Mo Flow Meter Small Series by Xierke

Complete analysis of Small Series flowmeter series

1. Product Overview

The Small Series is a designDurable, highly versatile, and extremely reliableThe traffic monitoring device is designed specifically for use in the most demanding environments. It provides through mechanical pointers, switches, transmitters, or digital flow/total quantity displaysContinuous local traffic monitoringThis series can be made of various materials and is suitable for a wide range of liquid, air, and gas applications.

2. Core Functions&Principles

  • working principle: AdoptingVane styleDesign. The fluid pushes a blade supported by a spring, which moves within the contour opening to form a variable orifice. The larger the flow rate, the larger the opening of the orifice, allowing fluid to pass through.

  • reset mechanismThe blades are loaded by springs and can automatically reset when the flow rate decreases.

  • Installation requirementsModular design of:,No need for straight pipe sections before and after installationThus minimizing pressure drop and installation space to the greatest extent possible.

  • output typeProvide multiple output options, including pure mechanical indication, electrical switch, 4-20mA signal, potentiometer output, and digital display.

3. Key Technical Specifications

Flow Rate Range
FML series (liters/minute): Minimum Full Scale0-4 L/min, maximum full range0-70 L/min.
Pipe Size
1/4 'to 1'
Pressure Rating
Low pressure (LP)Up to 300 psi (20 Bar)
Medium Voltage (MP)Maximum 725 psi (50 Bar)
High Voltage (HP)Maximum 3000 psi (200 Bar)(Note: High pressure is only applicable to cast iron, steel, and stainless steel materials)
Viscosity Range
up to600 cSt(Li Si).
Accuracy
±3%(Within the full range).
Repeatability
The repeatability of the switch set point is1%.
Protection level (enclosure)
The standard protection level isIP65 (NEMA 4)(Suitable for sizes 2 1/2 'and below).
Installation Position
can beAny locationInstallation.

4. Model composition and code generator (Part Code Builder)

The models of the Small Series are highly customizable and follow the following code rules:

  • Series and Full Scale:

    • FML+Number: representsLitres/MinA series of units, with numbers representing full-scale values (such asFML30= 30 L/min)。

    • Other SeriesFMC (low flow rate), FMB (imperial gallon/minute), FMG (American gallon/minute), FMM (cubic meter/hour).

  • Material of Manufacturing:

    • ALAluminum alloy

    • B: Bronze

    • CICast Iron

    • SCarbon Steel

    • SSStainless Steel

    • PTFEPolytetrafluoroethylene (limited to ports below 4 ')

    • PVCPolyvinyl chloride (limited to ports below 4 ')

  • Pressure Rating:

    • LPLow Pressure (up to 300 psi)

    • MPMedium Pressure (up to 725 psi)

    • HPHigh Pressure (up to 3000 psi)

  • Electrical Options:

    • MEMechanical Pointer only

    • 3EESPDT 3-wire switch (standard)

    • 3EEGSPDT 3-wire switch (with gold contacts)

    • 4EESPDT 4-wire switch

    • 6EEDPDT 6-wire switch

    • 3EE(ATEX2),3EE(ATEX1),6EE(ATEX1)ATEX Explosion proof Certification Version

    • AIRPneumatic switch

    • POTPotentiometer output (0-10V, with specified resistance)

    • OUT4-20mA output

    • OUTX4-20mA output (ATEX)

    • TOTDigital traffic/total display

    • TOTXDigital Flow/Total Display (ATEX)

  • O-ring Seal Material:

    • S1Buna (nitrile rubber, -40 º C to+110 º C)

    • S2EPDM (Ethylene Propylene Diene Monomer Rubber, -40 º C to+150 º C)

    • S3Viton (fluororubber, -20 º C to+200 º C)

    • S4PTFE (polytetrafluoroethylene, -100 º C to+250 º C)

    • S5Perlast (perfluoroether rubber, -15 º C to+330 º C)

  • Flow Direction:

    • D1,D2,D3,D4Four different standard flow options.

  • Viscosity at Operating Temperature:

    • Directly indicate the viscosity value and unit, for example460cS.

  • Port Connections:

    • Threaded/butt welded connection:24=3',32=4',48=6',64=8 '.

    • flange connection:F10,F16,F25,F40(3 '-8'), etc., or specified according to standards such as ANSI, DIN.

5. Application Fields

This series of flow meters is suitable for a variety of fluids, including:

  • liquid: Water, deionized water, water-soluble oils (such as ethylene glycol), petroleum based fluids, synthetic based fluids, cooling fluids, corrosive fluids, paints, solvents.

  • gasAir and various gases (information such as gas density, maximum flow rate, operating temperature, and pressure should be provided for selection).

6. Main Benefits

  • High precision and high repeatability± 3% accuracy, 1% switch repeatability.

  • 高度定制化Can be calibrated to any unit, providing single/double scales for individual calibration.

  • Easy installationModular design, installed at any position without the need for straight pipe sections.

  • Low pressure lossDesign optimization with low pressure drop.

  • Wide applicabilityCan handle high viscosity fluids, with a variety of material options.

  • sturdy and durableSpecially designed for harsh environments, with a high level of protection.

7. Installation&Maintenance

  • installAs an online device installed between two flanges, there are no directional restrictions.

  • safetyThe product is a pressure accessory,Not used as a security attachmentUsers need to evaluate their applicability in the system on their own.

  • maintenanceCan be disassembled and maintained on site. Key precautions:Do not disassemble or adjust the springTo avoid affecting calibration.

summarySmall Series is a powerful and highly flexible industrial flow monitoring solution. Its core advantages lie in its robust blade design, wide flow and pressure range, and deep customization capability achieved through the "part code generator", enabling it to accurately match various complex application scenarios.

FML-50-AL-LP-3EE-460CS-8-S1-D1

FML-50-AL-LP-3EE-460CS-8-S1-D3

FML-30-AL-LP-3EE-460CS-8-S1-D1

FML-30-AL-LP-3EE-460CS-8-S1-D3

FML-70-AL-LP-3EE-460CS-8-S1-D1

FML-70-AL-LP-3EE-460CS-8-S1-D3


Flow-Mon 流量计 Small Series系列 希而科