E-mail
lyc@haonpower.com
-
Phone
13720726368
-
Address
7th Floor, Qianjin Building, No. 6 Gaoxin 1st Road, Xi'an High tech Zone
Xi'an Haonan Electronic Technology Co., Ltd
lyc@haonpower.com
13720726368
7th Floor, Qianjin Building, No. 6 Gaoxin 1st Road, Xi'an High tech Zone
DC110V input power supply HFC100-W/O series 87672401228
Electrical insulation
Single output(12 or24V)
Chassis assembly
Over temperature shutdown
10msPower outage bridging
External shutdown
Anti short circuit and anti no-load protection
redundancy -Parallelizable
Overvoltage protection in the output circuit, external power supply can also be used for positive output (OVP)
Immersion paint assembly
Fix components by bonding to prevent vibration
Temperature range:-40°Cto+85°C
European Railways (EMC)
Vin/V |
Vout/V |
Iout/A |
Type |
Order number |
14,4 - 154 |
12 |
8,3 |
HFC100-W/O |
87671201223 |
14,4 - 154 |
24 |
4,2 |
HFC100-W/O |
87672401228 |
14,4 - 154 |
12 |
8,3 |
HFC100-W/G |
87671201256 |
14,4 - 154 |
24 |
4,2 |
HFC100-W/G |
87672401252 |
Other types on request |
DC110V input power supply HFC100-W/O series 87672401228
AUTRONIC DC/DCconverterHFC100-W - 100Tile, suitable for railways, etc
AutronicRailway power converterHFC100-Wseries87672401228
AutronicpassHFC100-WRailway compatibility with wide inputDC/DCConverter series.
The output power is 100 Wa's converter provides14.4…154VDCThe input range has been established and set a standard among similar products.
All requirements used in railway technology are focused on small areas and graphic design
Obtained implementation.

Therefore,AutronicEffectively achieved efficiency92%The plug and play solution simplifies the design.
Meet railway specific requirements without the need for additional wiring through external components EMCrequirement
Other functions include active surge current limitation (10A)Active reverse polarity protection, as well as overvoltage, overheating, and overcurrent protection.
Integrated power supply fault bridging is a natural thing to do, adjust the output voltage (±10%)The possibility of running up to three converters in parallel is also the same.
The input voltage in Europe is covered by a converter, which simplifies the design and simplifies the approval process for customer applications.
Electrical insulation HFC100-WIt is based on the temperature levelTXDeveloped, available in70°CAt the temperature100W
Operate at high power without the need for derating 85°CAt least at the required temperature10 minute In addition to natural convection,
AutronicThe simple installation of the converter only requires three small solder pads at the bottom to dissipate the generated heat, and complex heat sinks are unnecessary.
The selection of printed circuit board materials is based on the fire resistance testing conducted.
Besides having 12Vor24VIn addition to the open framework solution for output voltage, there are two other options available,
A type with IP20Shell, another type used forDINInstallation of guide rails. Other output voltages can be provided upon request.