E-mail
525800722@qq.com
-
Phone
13833772600
-
Address
Cangzhou City, Hebei Province
Xian County Ruibo Lian Instrument and Equipment Sales Office
525800722@qq.com
13833772600
Cangzhou City, Hebei Province
YTHF-IICeramic tile recovery coefficient testerCeramic tile impact resistance tester, drop hammer impact tester
1、 Product Introduction
Ceramic tile recovery coefficient testerIt is to drop a steel ball from a fixed height onto the sample and measure its rebound height to determine the recovery coefficient. By measuring the recovery coefficient, the impact resistance of various bricks can be determined to meet national standardsGB/T3010.5-2016andIS010545-5: 1996The Restoration of Ceramic Bricks for One Use The coefficient determines the impact resistance of bricks.
2、 Product parameters
Fixed height of descent:1m
Steel ball size: diameter is(19±0.05) mmChromium steel ball
Time measurement accuracy: accurate to the millisecond level
Overall dimensions:280X360X1300mm (longXwideXhigh)
3、 Product Features
Intelligent digital display: LCD display, intuitive reading;
Structural stability: Double fixation, with the falling ball perpendicular to the center of the specimen;
Transparent conduit: convenient for observation, with a bounce height for falling balls;
Complete accessories: drop ball2One, testing rack1One, LCD controller1One.
Ceramic tile thickness measuring instrumentCHD-1000Ceramic tile thickness gauge, testing instrument, thickness gauge
1、 Product Introduction
Ceramic tile thickness measuring instrument(Hereinafter referred to as thickness gauge)It is an instrument used to measure the thickness of large-sized ceramic tiles that cannot be measured by ordinary measuring tools, and can also be used to measure other materials(Such as marble slabs, gypsum slabs, etc)Measurement of product thickness. This thickness gauge uses a dial gauge for measurement, which has the advantages of high accuracy, accurate reading, easy operation, and convenient portability. It is a good instrument for manufacturers and quality inspection units.
2、 Product parameters
Product accuracy: ±0.1mm
Measurement range:1000×1000mm
Measure thickness:30mm
3、 Operating instructions
1Release the upper limit spring of the dial gauge, put down the dial gauge probe, and zero the dial gauge;
2Lift the dial gauge probe, limit the dial gauge with a spring clip, and adjust the probe2The plane is in full contact with the tested sample plane;
3Measure the thickness of the ceramic tile using the thickness gauge as shown in the diagram, and record the reading on the dial gauge in the corresponding table. This is the thickness of the ceramic tile to be measured;
4Repeat2、3Step by step, until all samples have been measured, clean the site, and wipe off the instruments;
5Remove the dial gauge and pack the thickness gauge for future use.