Welcome Customer !

Membership

Help

Anhui Tiankang (Group) Co., Ltd
Custom manufacturer

Main Products:

intelligent-mfg>Products

Anhui Tiankang (Group) Co., Ltd

  • E-mail

    2558004228@qq.com

  • Phone

    15055008418

  • Address

    No. 20 Renhe South Road, Tianchang City, Anhui Province

Contact Now

Armored computer cable, Tiankang armored computer cable

NegotiableUpdate on 02/21
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Armored computer cable, Tiankang Armored Computer Cable, is used for the transmission of analog and digital signals in instrument control systems. According to IEC79-14 classification, it can be used in Group II Zone 1 and Zone 2 environments and cannot be directly connected to low impedance power sources, such as public power supply stations. Recommended for indoor and outdoor installation, brackets, trays, pipelines, dry and wet environments, not recommended for direct burial. Recommended for application in fire prevention measures for life and important property materials. RE-2X (St) YSWAY 16C1.5 multi-core armored instrument cable
Product Details

Armored computer cable, Tiankang armored computer cableapplication

EN 50288-7 standard instrument cables are used for the transmission of analog and digital signals in instrument control systems. According to IEC79-14 classification, they can be used in Group II Zone 1 and Zone 2 environments and cannot be directly connected to low impedance power sources, such as public power supply stations. Recommended for indoor and outdoor installation, brackets, trays, pipelines, dry and wet environments, not recommended for direct burial. Recommended for application in fire prevention measures for life and important property materials.

Armored computer cable, Tiankang armored computer cablestandard

The basic design follows the EN 50288-7 standard

Fireproof characteristics

Flame retardant properties (single cable vertical combustion test) EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1; NBN C 30-004 (Cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*
Reduce fire spread (vertical flame combustion test of multiple cable bundles)*** EN 60332-3-24 (Cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (Cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4
halogen-free IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1*
Cable burning corrosive gases* IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2*
The lowest smoke density during cable combustion IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*
Non toxic testing of cables NES 02-713; NF C 20-454
UV-resistant UL 1581 section 1200
oil-resistant ICEA S-73-532**

Note: * is the replaced standard, * * * is the optional standard.

rated voltage

500V

structure

conductor IEC 60228 standard Class 1 solid annealed copper conductor or Class 2 multi strand plain copper conductor.
insulation EN 50290-2-29 standard extruded XLPE composite insulation.
Total shielding Aluminum tape/polyester tape layer shielding with 0.5mm2 tinned copper busbar.
inner sheath Thermoplastic PVC composite.
armor Galvanized steel wire armor
outer sheath EN 50290-2-22 standard thermoplastic PVC composite. UV protection, hydrocarbon resistance, oil resistance, rodent and termite resistance are all optional features. Compliance with fire and flame retardant performance standards (IEC 60332-1, IEC60332-3, UL 1581, UL1666, etc.) depends on the oxygen index of PVC composites and cable design. LSPVC can be selected according to requirements.
color Insulation: Black. Outer sheath: black or blue (intrinsic safety system)

Physical and thermal properties

Working temperature range (fixed state): -30 ° C -+90 ° C

Installation temperature range (motion state): -5 ° C -+50 ° C

Zui small bending radius: 10 X outer diameter

UV resistance: UL 1581 section 1200

Oil resistance: ICEA S-73-532 (tested at+60 ° C for 4 hours). During the 4-hour process, maintain the minimum values of tensile strength and elongation at 60%. )

Electrical performance

What is the cross-sectional area of the conductor? MM2? 0.5 0.75 1 1.3 1.5 2.5
Nominal insulation thickness MM 0.55 0.55 0.55 0.6 0.6 0.7
Conductor resistance (20 ° C)? ?Ω/KM? 36.7 25 18.5 14.2 12.3 7.4
Insulation resistance (20 ° C) MΩ. KM(MIN.) 5000?
Interaction capacitance (1 KHZ)? PF/M(MAX.) 115?
Unbalanced capacitance value (1 KHZ)? PF/500 M (MAX.) 500?
Induction coefficient/impedance ratio ΜH/Ω(MAX.) 25 25 25 40 40 60
Working voltage? V 500?
Test voltage URMS? Between wire cores V? 2000?
Between the wire core and the shielding V? 2000?

structural parameters

cable model RE-2X(ST)YSWAY
Number of cores x 1 x cross-sectional area Nominal insulation thickness Nominal inner sheath thickness Nominal total outer diameter of inner sheath layer Nominal armor layer thickness Nominal outer sheath thickness Nominal total outer diameter Nominal total weight
NO.X1XMM2 MM MM MM MM MM MM KG/KM
0.5mm2, multi-core
RE-2X(St)YSWAY 2C0.5 2x1x0.5 0.55 0.9 6.2 0.9 1.3 10.6 210
RE-2X(St)YSWAY 3C0.5 3x1x0.5 0.55 0.9 6.5 0.9 1.3 10.9 230
RE-2X(St)YSWAY 4C0.5 4x1x0.5 0.55 0.9 7 0.9 1.3 11.4 253
RE-2X(St)YSWAY 5C0.5 5x1x0.5 0.55 0.9 7.6 0.9 1.3 12 283
RE-2X(St)YSWAY 8C0.5 8x1x0.5 0.55 1 9.1 0.9 1.4 13.7 344
RE-2X(St)YSWAY 10C0.5 10x1x0.5 0.55 1 10.4 0.9 1.4 15 399
RE-2X(St)YSWAY 12C0.5 12x1x0.5 0.55 1 10.7 0.9 1.4 15.3 442
RE-2X(St)YSWAY 14C0.5 14x1x0.5 0.55 1 11.3 0.9 1.4 15.9 474
RE-2X(St)YSWAY 16C0.5 16x1x0.5 0.55 1.1 11.8 0.9 1.4 16.4 505
RE-2X(St)YSWAY 20C0.5 20x1x0.5 0.55 1.1 13.3 0.9 1.5 18.1 569
RE-2X(St)YSWAY 24C0.5 24x1x0.5 0.55 1.1 14.7 0.9 1.5 19.5 642
RE-2X(St)YSWAY 27C0.5 27x1x0.5 0.55 1.2 15 0.9 1.5 19.8 808
RE-2X(St)YSWAY 30C0.5 30x1x0.5 0.55 1.2 15.7 0.9 1.5 20.5 848
RE-2X(St)YSWAY 37C0.5 37x1x0.5 0.55 1.2 16.9 0.9 1.6 21.9 963
RE-2X(St)YSWAY 40C0.5 40x1x0.5 0.55 1.2 17.6 1.25 1.6 23.3 1014
0.75mm2, multi-core
RE-2X(St)YSWAY 2C0.75 2x1x0.75 0.55 0.9 6.5 0.9 1.3 10.9 230
RE-2X(St)YSWAY 3C0.75 3x1x0.75 0.55 0.9 6.9 0.9 1.3 11.3 247
RE-2X(St)YSWAY 4C0.75 4x1x0.75 0.55 0.9 7.4 0.9 1.3 11.8 278
RE-2X(St)YSWAY 5C0.75 5x1x0.75 0.55 0.9 8.1 0.9 1.4 12.7 322
RE-2X(St)YSWAY 8C0.75 8x1x0.75 0.55 1 9.7 0.9 1.4 14.3 383
RE-2X(St)YSWAY 10C0.75 10x1x0.75 0.55 1 11.1 0.9 1.4 15.7 461
RE-2X(St)YSWAY 12C0.75 12x1x0.75 0.55 1 11.5 0.9 1.4 16.1 477
RE-2X(St)YSWAY 14C0.75 14x1x0.75 0.55 1.1 12.2 0.9 1.5 17 527
RE-2X(St)YSWAY 16C0.75 16x1x0.75 0.55 1.1 12.9 0.9 1.5 17.7 572
RE-2X(St)YSWAY 20C0.75 20x1x0.75 0.55 1.1 14.3 0.9 1.5 19.1 669
RE-2X(St)YSWAY 24C0.75 24x1x0.75 0.55 1.2 16 0.9 1.5 20.8 877
RE-2X(St)YSWAY 27C0.75 27x1x0.75 0.55 1.2 16.3 0.9 1.6 21.3 929
RE-2X(St)YSWAY 30C0.75 30x1x0.75 0.55 1.2 16.9 0.9 1.6 21.9 986
RE-2X(St)YSWAY 37C0.75 37x1x0.75 0.55 1.2 18.2 1.25 1.6 23.9 1102
RE-2X(St)YSWAY 40C0.75 40x1x0.75 0.55 1.3 19.1 1.25 1.6 24.8 1181
1.0mm2, multi-core
RE-2X(St)YSWAY 2C1.0 2x1x1.0 0.55 0.9 6.9 0.9 1.3 11.3 247
RE-2X(St)YSWAY 3C1.0 3x1x1.0 0.55 0.9 7.3 0.9 1.3 11.7 270
RE-2X(St)YSWAY 4C1.0 4x1x1.0 0.55 0.9 7.9 0.9 1.4 12.5 299
RE-2X(St)YSWAY 5C1.0 5x1x1.0 0.55 0.9 8.6 0.9 1.4 13.2 342
RE-2X(St)YSWAY 8C1.0 8x1x1.0 0.55 1 10.3 0.9 1.4 14.9 424
RE-2X(St)YSWAY 10C1.0 10x1x1.0 0.55 1 11.9 0.9 1.4 16.5 514
RE-2X(St)YSWAY 12C1.0 12x1x1.0 0.55 1 12.2 0.9 1.5 17 548
RE-2X(St)YSWAY 14C1.0 14x1x1.0 0.55 1.1 13 0.9 1.5 17.8 590
RE-2X(St)YSWAY 16C1.0 16x1x1.0 0.55 1.1 13.7 0.9 1.5 18.5 649
RE-2X(St)YSWAY 20C1.0 20x1x1.0 0.55 1.1 15.2 0.9 1.5 20 864
RE-2X(St)YSWAY 24C1.0 24x1x1.0 0.55 1.2 17 0.9 1.6 22 1005
RE-2X(St)YSWAY 27C1.0 27x1x1.0 0.55 1.2 17.4 1.25 1.6 23.1 1058
RE-2X(St)YSWAY 30C1.0 30x1x1.0 0.55 1.2 18 1.25 1.6 23.7 1113
RE-2X(St)YSWAY 37C1.0 37x1x1.0 0.55 1.2 19.6 1.25 1.6 25.3 1271
RE-2X(St)YSWAY 40C1.0 40x1x1.0 0.55 1.3 20.4 1.25 1.7 26.3 1351
1.3mm2, multi-core
RE-2X(St)YSWAY 2C1.3 2x1x1.3 0.6 0.9 7.4 0.9 1.3 11.8 275
RE-2X(St)YSWAY 3C1.3 3x1x1.3 0.6 0.9 7.9 0.9 1.3 12.3 295
RE-2X(St)YSWAY 4C1.3 4x1x1.3 0.6 0.9 8.5 0.9 1.4 13.1 340
RE-2X(St)YSWAY 5C1.3 5x1x1.3 0.6 1 9.5 0.9 1.4 14.1 383
RE-2X(St)YSWAY 8C1.3 8x1x1.3 0.6 1 11.2 0.9 1.4 15.8 483
RE-2X(St)YSWAY 10C1.3 10x1x1.3 0.6 1.1 13.2 0.9 1.5 18 578
RE-2X(St)YSWAY 12C1.3 12x1x1.3 0.6 1.1 13.6 0.9 1.5 18.4 633
RE-2X(St)YSWAY 14C1.3 14x1x1.3 0.6 1.1 14.3 0.9 1.5 19.1 698
RE-2X(St)YSWAY 16C1.3 16x1x1.3 0.6 1.1 15 0.9 1.5 19.8 870
RE-2X(St)YSWAY 20C1.3 20x1x1.3 0.6 1.2 16.9 0.9 1.6 21.9 1014
RE-2X(St)YSWAY 24C1.3 24x1x1.3 0.6 1.2 18.7 1.25 1.6 24.4 1163
RE-2X(St)YSWAY 27C1.3 27x1x1.3 0.6 1.3 19.3 1.25 1.6 25 1227
RE-2X(St)YSWAY 30C1.3 30x1x1.3 0.6 1.3 20 1.25 1.6 25.7 1305
RE-2X(St)YSWAY 37C1.3 37x1x1.3 0.6 1.3 21.6 1.25 1.7 27.5 1504
RE-2X(St)YSWAY 40C1.3 40x1x1.3 0.6 1.4 22.7 1.25 1.7 28.6 1584
1.5mm2, multi-core
RE-2X(St)YSWAY 2C1.5 2x1x1.5 0.6 0.9 7.7 0.9 1.3 12.1 279
RE-2X(St)YSWAY 3C1.5 3x1x1.5 0.6 0.9 8.1 0.9 1.4 12.7 322
RE-2X(St)YSWAY 4C1.5 4x1x1.5 0.6 0.9 8.8 0.9 1.4 13.4 347
RE-2X(St)YSWAY 5C1.5 5x1x1.5 0.6 1 9.8 0.9 1.4 14.4 392
RE-2X(St)YSWAY 8C1.5 8x1x1.5 0.6 1 11.6 0.9 1.4 16.2 518
RE-2X(St)YSWAY 10C1.5 10x1x1.5 0.6 1.1 13.7 0.9 1.5 18.5 614
RE-2X(St)YSWAY 12C1.5 12x1x1.5 0.6 1.1 14.1 0.9 1.5 18.9 670
RE-2X(St)YSWAY 14C1.5 14x1x1.5 0.6 1.1 14.8 0.9 1.5 19.6 742
RE-2X(St)YSWAY 16C1.5 16x1x1.5 0.6 1.1 15.6 0.9 1.5 20.4 925
RE-2X(St)YSWAY 20C1.5 20x1x1.5 0.6 1.2 17.6 1.25 1.6 23.3 1062
RE-2X(St)YSWAY 24C1.5 24x1x1.5 0.6 1.3 19.6 1.25 1.6 25.3 1218
RE-2X(St)YSWAY 27C1.5 27x1x1.5 0.6 1.3 20.1 1.25 1.6 25.8 1289
RE-2X(St)YSWAY 30C1.5 30x1x1.5 0.6 1.3 20.8 1.25 1.7 26.7 1418
RE-2X(St)YSWAY 37C1.5 37x1x1.5 0.6 1.4 22.6 1.25 1.7 28.5 1586
RE-2X(St)YSWAY 40C1.5 40x1x1.5 0.6 1.4 23.6 1.25 1.7 29.5 1687
2.5mm2, multi-core
RE-2X(St)YSWAY 2C2.5 2x1x2.5 0.7 0.9 8.9 0.9 1.4 13.5 364
RE-2X(St)YSWAY 3C2.5 3x1x2.5 0.7 1 9.7 0.9 1.4 14.3 389
RE-2X(St)YSWAY 4C2.5 4x1x2.5 0.7 1 10.5 0.9 1.4 15.1 430
RE-2X(St)YSWAY 5C2.5 5x1x2.5 0.7 1 11.9 0.9 1.4 16.5 547
RE-2X(St)YSWAY 8C2.5 8x1x2.5 0.7 1.1 13.9 0.9 1.5 18.7 684
RE-2X(St)YSWAY 10C2.5 10x1x2.5 0.7 1.2 16.3 0.9 1.6 21.3 952
RE-2X(St)YSWAY 12C2.5 12x1x2.5 0.7 1.2 16.9 0.9 1.6 21.9 1012
RE-2X(St)YSWAY 14C2.5 14x1x2.5 0.7 1.2 17.7 1.25 1.6 23.4 1126
RE-2X(St)YSWAY 16C2.5 16x1x2.5 0.7 1.3 18.9 1.25 1.6 24.6 1252
RE-2X(St)YSWAY 20C2.5 20x1x2.5 0.7 1.3 21.1 1.25 1.7 27 1456
RE-2X(St)YSWAY 24C2.5 24x1x2.5 0.7 1.4 23.6 1.25 1.7 29.5 1644
RE-2X(St)YSWAY 27C2.5 27x1x2.5 0.7 1.4 24.1 1.25 1.8 30.2 1811
RE-2X(St)YSWAY 30C2.5 30x1x2.5 0.7 1.5 25.2 1.25 1.8 31.3 2154
RE-2X(St)YSWAY 37C2.5 37x1x2.5 0.7 1.5 27.2 1.25 1.8 33.3 2477
RE-2X(St)YSWAY 40C2.5 40x1x2.5 0.7 1.6 28.5 1.25 1.9 34.8 2614

Note: Other specifications of cross-sectional area and wire core requirements can be customized according to requirements.