| Project Model Model Model | HS40DPE | ||
| Pump water pump | Suction prot diameter inlet diameter | mm | 100 (4 ") |
| Discharge prot diameter outlet diameter | mm | 100 (4 ") | |
| Max.capa city traffic | m3h | 96 | |
| Cont.Head lift head | m | 31 | |
| Max.section head suction | m | 8 | |
| Engine engine | Model: Engine model | HS-186FA | |
| Engine type Engine form | Single cylinder,4-stroke,air-cooled ,diesel engine Single cylinder, four stroke, air-cooled, diesel engine |
||
| Bore x Stroke cylinder diameter x stroke | 86*72 | ||
| Compression ratio | 19:1 | ||
| Cubic cc.: Discharge consumption | cc | 416 | |
| Max.outpur(3600rpm) 功率 | KW | 9.2 | |
| Alimentation: Fuel supply method | Natural self flowing type | ||
| Cooling system: cooling method | Air cooled | ||
| Starting system: Starting method | Recoil/Electric starter Hand Pull/Electric Start | ||
| Rpm: Speed | rpm | 3600 | |
| Oil capacity: oil capacity | L | 1.65 | |
| Fuel tank capacity | L | 5.5 | |
| Fuel consumption ratio | g/kW.h | 275.1 | |
| Lube.brand lubricant model | CD grade or SAE10W-30, 15W-40 diesel engine oil | ||
| Fuel type Fuel model | 0 # in summer, -10 # in winter, diesel oil | ||
| Standard Features Standard Configuration | Connector of inlet and outlet pipe fittings | Yes, there is | |
| Filter Filter | Yes, there is | ||
| Seal ring | Yes, there is | ||
| Hoop clamp | Yes, there is | ||
| Big fuel tank capacity | Optional | ||
| Electric starter | Optional | ||
| Size Size | Packing size (L × W × H) | mm | 650*480*610 |
| Net/Gross weight | kg | 69/71 | |
| 20FT Qty | 60 | ||
| 40FT Qty | 130 | ||

2 3 4 inch small diesel engine water pump
The automatic control operation process of the Hansi generator set is as follows:
1Keep the battery pack of the starter motor at the starting voltage.
2Keep the cooling water level of the radiator normal and keep the circulating water valve open.
3Maintain the crankcase oil level at the dipstick mark ±2cmWithin the scope.
4The fuel level in the fuel tank is more than half, and the fuel supply valve is normally open.
5Place the "Run Stop Auto" switch on the generator control panel in the "Auto" position.
6The mode switch of the generator set distribution panel is in the "automatic" position.
7Set the switch of the radiator fan to the "automatic" position.
8After receiving the signal of mains voltage loss, the unit starts up, confirms the mains voltage loss, cuts open the mains switch of the conversion cabinet, closes the power generation switch of the conversion cabinet, and starts the intake and exhaust fans in the machine room.
After my explanation, I hope it can be helpful to you. Hansi Care:
Precautions for editing this paragraph: The starter motor is used as a diesel generator setzuiOne of the important components, when using it, pay attention to the following points: 1After the preparation work is done, lift the start button, and the diesel engine gears will mesh with the flywheel ring gear and start running. Under normal circumstances, it can be started in one go. If the first start is unsuccessful, the starter armature must be stopped before proceeding to the next start. Otherwise, the starter gear will be severely impacted with the diesel engine ring gear and damaged.
2Each start-up time shall not exceed5The interval between second starts should be greater than2minute.
3When the engine fails to start several times in a row, the starter, diesel engine, battery, and wiring should be checked, and the fault should be eliminated before starting again.
4Once the diesel engine is started, the start button should be immediately released to allow the starter gear to return to its original position and stop working, in order to prevent damage to the starter due to overspeed.