Environmentally friendly WDZ-BPYJEP2 cable,WDZ-BPYJEPP2 Variable Frequency Cable
The structure of a frequency conversion cable includes three main insulated wires and three neutral insulated wires. An inner winding layer, a copper strip layer, an outer winding layer, and an outer sheath layer are sequentially set outside the main insulated wires and neutral insulated wires to form a 3+3 core structure, which makes the cable have strong voltage impact resistance and can withstand pulse voltage during high-speed and frequent frequency conversion, providing good protection for frequency conversion electrical appliances
Wdz-bpyjep 2 |
Cross linked polyethylene insulated low smoke halogen-free flame-retardant sheathed copper tape shielded frequency converter cable |
Wdz-bpyjepp 2 |
Cross linked polyethylene insulated low smoke halogen-free flame-retardant sheathed copper wire braided copper tape wrapped double shielded frequency converter cable |
The rated voltage of a cable is the reference voltage used for cable design, use, and electrical performance testing.
Rated voltage using U0/U represents.
U0Indicate the effective voltage value between any main insulated conductor and "ground" (metal shield, metal sheath, or surrounding medium); U is a multi-core battery
The effective value of voltage between any two conductors in a cable or single core cable system.
In communication systems, the rated voltage of cables should be at least equal to the nominal voltage of the system in which the cables are used. This condition applies to U0Both U value and U value are applicable; In a DC system, the standard voltage of the system should not exceed 1.5 times the rated voltage of the cable.
Note: The operating voltage of the system is allowed to exceed the nominal voltage of the system for a long time10%If the rated voltage of the cable is at least equal to the nominal voltage of the system, The cable can operate at voltages higher than the rated voltage10%Used under the working voltage.
000011.1 Definition of size values (thickness, cross-sectional area, etc.)
000011.1.1Nominal value
The value of is often used in tables and is usually derived from the nominal value in this specificationquantityConsider specifying tolerances for values and verify them through measurement.
000011.1.2Approximate value
A value that is neither guaranteed nor checked, such as due to the calculation of other dimensional values.
000011.1.3Intermediate value
When arranging several values obtained from the experiment in ascending (or descending) order, if the number of values is odd, the middle value is the middle value; if the number of values is even, the average of the two middle values is the middle value.
000011.1.4falsefixed值 Gictitious value
According to Appendix A(normativityAppendix) Calculated values.
Environmentally friendly WDZ-BPYJEP2 cable,WDZ-BPYJEPP2 Variable Frequency CableSold to:Beijing, Shanghai, Tianjin, Chongqing Hebei, Shanxi, Shaanxi, Shandong, Henan, Liaoning, Jilin, Heilongjiang, Jiangsu Zhejiang, Anhui, Jiangxi, Fujian, Hubei, Hunan, Sichuan, Guizhou, Yunnan, Guangdong, Hainan, Gansu, Qinghai、Inner Mongolia, Xinjiang, Xizang, Guangxi, Ningxia