VEGAFLEX 65 German Guided Wave Radar Level Gauge/Material Level Gauge

Product Details

Guided wave radar level gauge/material level gauge (VEGAFLEX 65)

Measurement principle

The new VEGAFLE60 series sensor imported from Germany is used for precise measurement of the level of solid or liquid media. The principle is to send extremely short microwave pulses along a steel cable, rod, or casing. When the microwave signal contacts a solid or liquid medium, a portion of the energy is reflected back. The VEGAFLEX60 series guided wave radar sensor can measure the microwave operating time with high accuracy through special radar scanning technology, thereby calculating the distance between the sensor and the medium. Due to its simple measurement principle, VEGAFLEX level gauges/level gauges/level gauges can be adjusted without material, thus saving a lot of debugging costs. The measuring cable or rod can be shortened to make it more suitable for on-site applications.

Not sensitive to changes in dust, steam, and medium density

Even in environments with strong dust, smoke, noise, and steam, measurement accuracy is not affected. Changes in medium density, particle size, and even liquefaction will not affect measurement accuracy. When the gravel layer changes from dry to wet, it will not affect the measurement.

Not affected by adhesive media

The adhesive medium on the measuring probe or container wall will not affect the measurement results.

Easy installation and debugging

If a coaxial sleeve type VEGAFLEX guided wave radar level gauge/level gauge/level gauge is used, the measurement is completely unaffected by the installation of objects inside the container, such as heating tubes or supports. No special debugging is required.

Main performance parameters

scope of application liquid
Measuring distance Coaxial tube type 6-meter
measurement accuracy ± 3 millimeters
Ambient Temperature -40~150℃
Work environment pressure -1~40bar (-100~4000 KPa)

■ Selection Guide

Security certification:
XX
┄
┄
┄
┄
┄
┄
┄
┄
┄
No explosion-proof requirements
XM
┄
┄
┄
┄
┄
┄
┄
┄
┄
Marine license
CX
┄
┄
┄
┄
┄
┄
┄
┄
┄
ATEX II 1G, 1/2G, 2G EEx ia IIC T6
CA
┄
┄
┄
┄
┄
┄
┄
┄
┄
ATEX II 1G, 1/2G, 2G EEx ia IIC T6 + WHG
CM
┄
┄
┄
┄
┄
┄
┄
┄
┄
ATEX II 1G, 1/2G, 2G EEx ia IIC T6+Marine License
DX
┄
┄
┄
┄
┄
┄
┄
┄
┄
ATEX II 1/2G, 2G EEx d ia IIC T6
│
Version/Material:
│
A
┄
┄
┄
┄
┄
┄
┄
┄
Coaxial detection tube/316L
│
│
Installation connection/materials:
│
│
GB
┄
┄
┄
┄
┄
┄
┄
Screw mouth G3/4A PN40/316L
│
│
NB
┄
┄
┄
┄
┄
┄
┄
Screw mouth 3/4NPT PN40/316L
│
│
GC
┄
┄
┄
┄
┄
┄
┄
Screw G1A PN40/316L
│
│
NC
┄
┄
┄
┄
┄
┄
┄
Screw mouth 1NPT PN40/316L
│
│
GD
┄
┄
┄
┄
┄
┄
┄
Screw G1 1/2 PN40/316L
│
│
ND
┄
┄
┄
┄
┄
┄
┄
Screw 1/2NPT PN40/316L
│
│
FA
┄
┄
┄
┄
┄
┄
┄
Flange DN25PN40 Form C, DIN2501/316L
│
│
FB
┄
┄
┄
┄
┄
┄
┄
Flange DN40PN40 Form C, DIN2501/316L
│
│
FC
┄
┄
┄
┄
┄
┄
┄
Flange DN50PN40 Form C, DIN2501/316L
│
│
FD
┄
┄
┄
┄
┄
┄
┄
Flange DN80PN40 Form C, DIN2501/316L
│
│
AA
┄
┄
┄
┄
┄
┄
┄
Flange 1 "150lb RF, ANSI B16.5/316L
│
│
AE
┄
┄
┄
┄
┄
┄
┄
Flange 2 "150lb RF, ANSI B16.5/316L
│
│
AI
┄
┄
┄
┄
┄
┄
┄
Flange 3 "150lb RF, ANSI B16.5/316L
│
│
│
Sealing/working temperature:
│
│
│
1
┄
┄
┄
┄
┄
┄
FKM (Viton) / -40~150°C
│
│
│
2
┄
┄
┄
┄
┄
┄
Kalrez 6375 / -20~150°C
│
│
│
3
┄
┄
┄
┄
┄
┄
EPDM / -40~150°C
│
│
│
│
Output interface:
│
│
│
│
H
┄
┄
┄
┄
┄
Two line system, 4-20mA/HART
│
│
│
│
P
┄
┄
┄
┄
┄
Profibus PA
│
│
│
│
F
┄
┄
┄
┄
┄
Foundation Fieldbus
│
│
│
│
│
Shell/Protection Level:
│
│
│
│
│
K
┄
┄
┄
┄
Plastic casing/IP66/IP67
│
│
│
│
│
A
┄
┄
┄
┄
Aluminum casing/IP66/IP68 (0.2 bar)
│
│
│
│
│
D
┄
┄
┄
┄
Aluminum shell double chamber/IP66/IP68 (0.2 bar)
│
│
│
│
│
8
┄
┄
┄
┄
StSt (electrolytic polishing) 316L/IP66/IP68 (0.2 bar)
│
│
│
│
│
│
Connecting cables/cable sealing covers/connecting plugs:
│
│
│
│
│
│
M
┄
┄
┄
M20x1.5/Yes/No
│
│
│
│
│
│
N
┄
┄
┄
1/2NPT/None/None
│
│
│
│
│
│
│
Display Debugging Module (PLICSCOM):
│
│
│
│
│
│
│
X
┄
┄
not have
│
│
│
│
│
│
│
A
┄
┄
Top installation
│
│
│
│
│
│
│
│
Additional equipment:
│
│
│
│
│
│
│
│
X
┄
not have
↓
↓
↓
↓
↓
↓
↓
↓
↓
FX65.
##
#
##
#
#
#
#
#
#