VEGA pressure sensor (VEGABAR 52) pressure transmitter from Germany

Product Details

Pressure sensor (VEGABAR 52)

■Measurement principle:

Vegabar is a device specifically designed to measure the pressure of gases, vapors, and liquids at high temperatures. The core of a pressure transmitter is the pressure measurement unit that converts pressure into an electrical signal. The existing pressure acts on the sensing element through the process diaphragm and isolation fluid, generating a signal. The built-in integrated electronic components convert this pressure generated signal into a standardized output signal. The ceramic measuring unit has a long and stable service life, and has good overload resistance characteristics. Metal METEC ® The measuring unit is a fully welded version, covering a wider measurement range.

■Advantages:

-Dry ceramic capacitive sensor components.

-High measurement accuracy.

-Anti overload and vacuum resistance.

-There is a very small measurement range.

■Application:

The VEGABAR52 sensing element uses sturdy ceramic CERTEC ® Measure the unit diaphragm. The process pressure causes a change in the capacitance of the measurement unit, which is converted into corresponding output and input signals as measurement values. CERTEC ® The measuring unit is also equipped with a temperature sensor, and the temperature value can be displayed through an indication and adjustment module or processed through signal output. VEGABAR52 is used to measure gas, vapor, and liquid media.

■Main performance parameters

Scope of application

Gas, steam, and liquid media

Measurement unit

Ceramic CERTEC ® Measurement unit

Measurement range

-1~60bar (-100~6000 kPa)

Measurement accuracy

0.2 %; 0.1%; 0.075%

Working environment temperature

-40~150℃

■ Selection Guide

Security certification:
XX
┄
┄
┄
┄
┄
┄
┄
┄
┄
No explosion-proof requirements
XM
┄
┄
┄
┄
┄
┄
┄
┄
┄
Marine license
CX
┄
┄
┄
┄
┄
┄
┄
┄
┄
ATEX II 1G,1/2G, 2G Ex ia IIC T6
CA
┄
┄
┄
┄
┄
┄
┄
┄
┄
ATEX II 1G,1/2G, 2G Ex ia IIC T6+WHG
CM
┄
┄
┄
┄
┄
┄
┄
┄
┄
ATEX II 1G, 1/2G, 2G Ex ia IIC T6+Marine License
CI
┄
┄
┄
┄
┄
┄
┄
┄
┄
Zone0,0/1,1 Ex ia IIC T6
DX
┄
┄
┄
┄
┄
┄
┄
┄
┄
ATEX II 1/2G, 2G Ex d ia IIC T6
GX
┄
┄
┄
┄
┄
┄
┄
┄
┄
ATEX II 1/2D, 2D IP6X T
│
Installation connection/materials:
│
GV
┄
┄
┄
┄
┄
┄
┄
┄
Screw G1/2A pressure gauge connection PN160/316L
│
GP
┄
┄
┄
┄
┄
┄
┄
┄
Screw G1/2A, internal thread G1/4A PN160/316L
│
GG
┄
┄
┄
┄
┄
┄
┄
┄
Screw mouth G11/2A PN60 / 316L
│
GW
┄
┄
┄
┄
┄
┄
┄
┄
Screw mouth G11/2A PN10 / PVDF
│
GN
┄
┄
┄
┄
┄
┄
┄
┄
1/2NPT thread, 1/4NPT PN160/316L internal thread
│
CA
┄
┄
┄
┄
┄
┄
┄
┄
Clamp 2 "PN16/316L
│
LA
┄
┄
┄
┄
┄
┄
┄
┄
Aseptic and anti-corrosion connection F40 PN40/316L with slotted connection screw sleeve
│
TA
┄
┄
┄
┄
┄
┄
┄
┄
Online plug-in connection Varivent N50-40 PN25/316L
│
RD
┄
┄
┄
┄
┄
┄
┄
┄
Pipe joint DN50PN25 Form A DIN11864/316L
│
BB
┄
┄
┄
┄
┄
┄
┄
┄
Screw M44x1.25 (DIN13) stainless steel pressure screw PN60/316 L
│
FB
┄
┄
┄
┄
┄
┄
┄
┄
Flange DN50PN40 Form C, DIN2501/316L
│
FE
┄
┄
┄
┄
┄
┄
┄
┄
Flange DN80PN40 Form C, DIN2501/316L
│
FH
┄
┄
┄
┄
┄
┄
┄
┄
Flange 2 "150lb RF, ANSI B16.5/316L
│
FI
┄
┄
┄
┄
┄
┄
┄
┄
Flange 3 "150lb RF, ANSI B16.5/316L
│
│
Sealed measuring unit/temperature:
│
│
1
┄
┄
┄
┄
┄
┄
┄
FKM (A+P 70.16) /-40...120°C
│
│
3
┄
┄
┄
┄
┄
┄
┄
EPDM (A+P 75.5/KW75F) / -40...120°C
│
│
M
┄
┄
┄
┄
┄
┄
┄
FFKM (Perlast G75B) / -15...120°C
│
│
│
Work pressure/measurement range:
│
│
│
A
┄
┄
┄
┄
┄
┄
rel. / 0…0.1bar(0…10kPa)
│
│
│
B
┄
┄
┄
┄
┄
┄
rel. / 0…0.2bar(0…20kPa)
│
│
│
C
┄
┄
┄
┄
┄
┄
rel. / 0…0.4bar(0…40kPa)
│
│
│
D
┄
┄
┄
┄
┄
┄
rel. / 0…1.0bar(0…100kPa)
│
│
│
E
┄
┄
┄
┄
┄
┄
rel. / 0…2.5bar(0…250kPa)
│
│
│
F
┄
┄
┄
┄
┄
┄
rel. / 0…5.0bar(0…500kPa)
│
│
│
G
┄
┄
┄
┄
┄
┄
rel. / 0…10.0bar(0…1000kPa)
│
│
│
P
┄
┄
┄
┄
┄
┄
rel. / -1…0.0bar(-100…0kPa)
│
│
│
Q
┄
┄
┄
┄
┄
┄
rel. / -1…1.5bar(-100…150kPa)
│
│
│
R
┄
┄
┄
┄
┄
┄
rel. / -1…5.0bar(-100…500kPa)
│
│
│
S
┄
┄
┄
┄
┄
┄
rel. / -1…10.0bar(-100…1000kPa)
│
│
│
K
┄
┄
┄
┄
┄
┄
rel. / -0.05…0.05bar(-5…5kPa)
│
│
│
L
┄
┄
┄
┄
┄
┄
rel. / -0.1…0.1bar(-10…10kPa)
│
│
│
M
┄
┄
┄
┄
┄
┄
rel. / -0.2…0.2bar(-20…20kPa)
│
│
│
1
┄
┄
┄
┄
┄
┄
abs / 0…1.0bar(0…100kPa)
│
│
│
2
┄
┄
┄
┄
┄
┄
abs / 0…2.5bar(0…250kPa)
│
│
│
3
┄
┄
┄
┄
┄
┄
abs / 0…5.0bar(0…500kPa)
│
│
│
│
Signal output:
│
│
│
│
Z
┄
┄
┄
┄
┄
Two line system, 4-20mA
│
│
│
│
H
┄
┄
┄
┄
┄
Two line system, 4-20mA/HART ®
│
│
│
│
P
┄
┄
┄
┄
┄
Fieldbus
│
│
│
│
F
┄
┄
┄
┄
┄
Fundamentals of Fieldbus
│
│
│
│
│
Shell/Protection Level:
│
│
│
│
│
K
┄
┄
┄
┄
Plastic casing IP66/IP67
│
│
│
│
│
A
┄
┄
┄
┄
Aluminum shell IP66/IP67
│
│
│
│
│
D
┄
┄
┄
┄
Aluminum shell double chamber IP66/IP67
│
│
│
│
│
8
┄
┄
┄
┄
Stainless steel (electrolytic polishing) 316L/IP66/IP67
│
│
│
│
│
P
┄
┄
┄
┄
PUR axial output cable IP68, split plastic shell IP65
│
│
│
│
│
W
┄
┄
┄
┄
Stainless steel double chamber casing/IP66/IP67
│
│
│
│
│
R
┄
┄
┄
┄
Plastic dual chamber casing/IP66/IP67
│
│
│
│
│
│
Connecting cables/cable sealing covers/connecting plugs:
│
│
│
│
│
│
M
┄
┄
┄
M20x1.5/Yes/No
│
│
│
│
│
│
N
┄
┄
┄
1/2NPT/None/None
│
│
│
│
│
│
│
Indication/Adjustment Module (PLISCOM):
│
│
│
│
│
│
│
X
┄
┄
not have
│
│
│
│
│
│
│
A
┄
┄
install
│
│
│
│
│
│
│
│
Accuracy level:
│
│
│
│
│
│
│
│
M
┄
0.075%
│
│
│
│
│
│
│
│
E
┄
0.10%
│
│
│
│
│
│
│
│
S
┄
0.20%
↓
↓
↓
↓
↓
↓
↓
↓
↓
BR52.
##
##
#
#
#
#
# # #