■Measurement principle:
Vegabar is a device specifically designed to measure the pressure of gases, vapors, and liquids at high temperatures. The core of a pressure transmitter is the pressure measurement unit that converts pressure into an electrical signal. The existing pressure acts on the sensing element through the process diaphragm and isolation fluid, generating a signal. The built-in integrated electronic components convert this pressure generated signal into a standardized output signal. The ceramic measuring unit has a long and stable service life, and has good overload resistance characteristics. Metal METEC ® The measuring unit is a fully welded version, covering a wider measurement range.
■Advantages:
-Dry ceramic capacitive sensor components.
-High measurement accuracy.
-Anti overload and vacuum resistance.
-There is a very small measurement range.
■Application:
The VEGABAR52 sensing element uses sturdy ceramic CERTEC ® Measure the unit diaphragm. The process pressure causes a change in the capacitance of the measurement unit, which is converted into corresponding output and input signals as measurement values. CERTEC ® The measuring unit is also equipped with a temperature sensor, and the temperature value can be displayed through an indication and adjustment module or processed through signal output. VEGABAR52 is used to measure gas, vapor, and liquid media.
■Main performance parameters
|
Scope of application |
Gas, steam, and liquid media |
|
Measurement unit |
Ceramic CERTEC ® Measurement unit |
|
Measurement range |
-1~60bar (-100~6000 kPa) |
|
Measurement accuracy |
0.2 %; 0.1%; 0.075% |
|
Working environment temperature |
-40~150℃ |
■ Selection Guide
|
|
|
|
|
|
|
|
Security certification: | ||||
|
XX
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
No explosion-proof requirements | |
|
XM
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
Marine license | |
|
CX
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
ATEX II 1G,1/2G, 2G Ex ia IIC T6 | |
|
CA
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
ATEX II 1G,1/2G, 2G Ex ia IIC T6+WHG | |
|
CM
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
ATEX II 1G, 1/2G, 2G Ex ia IIC T6+Marine License | |
|
CI
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
Zone0,0/1,1 Ex ia IIC T6 | |
| DX |
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
ATEX II 1/2G, 2G Ex d ia IIC T6 | |
| GX |
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
ATEX II 1/2D, 2D IP6X T | |
|
│
|
|
|
|
|
|
Installation connection/materials: | |||||
|
│
|
GV
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
Screw G1/2A pressure gauge connection PN160/316L | |
|
│
|
GP |
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
Screw G1/2A, internal thread G1/4A PN160/316L | |
|
│
|
GG |
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
Screw mouth G11/2A PN60 / 316L | |
|
│
|
GW |
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
Screw mouth G11/2A PN10 / PVDF | |
|
│
|
GN
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
1/2NPT thread, 1/4NPT PN160/316L internal thread | |
|
│
|
CA
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
Clamp 2 "PN16/316L | |
|
│
|
LA |
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
Aseptic and anti-corrosion connection F40 PN40/316L with slotted connection screw sleeve | |
|
│
|
TA |
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
Online plug-in connection Varivent N50-40 PN25/316L | |
|
│
|
RD |
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
Pipe joint DN50PN25 Form A DIN11864/316L | |
|
│
|
BB |
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
Screw M44x1.25 (DIN13) stainless steel pressure screw PN60/316 L | |
|
│
|
FB |
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
Flange DN50PN40 Form C, DIN2501/316L | |
|
│
|
FE
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
Flange DN80PN40 Form C, DIN2501/316L | |
|
│
|
FH
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
Flange 2 "150lb RF, ANSI B16.5/316L | |
|
│
|
FI
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
Flange 3 "150lb RF, ANSI B16.5/316L | |
|
│
|
│
|
|
|
|
|
Sealed measuring unit/temperature: | |||||
|
│
|
│
|
1 |
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
FKM (A+P 70.16) /-40...120°C | |
|
│
|
│
|
3 |
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
EPDM (A+P 75.5/KW75F) / -40...120°C | |
|
│
|
│
|
M |
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
FFKM (Perlast G75B) / -15...120°C | |
|
│
|
│
|
│
|
Work pressure/measurement range: | ||||||||
|
│
|
│
|
│
|
A |
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
rel. / 0…0.1bar(0…10kPa) | |
|
│
|
│
|
│
|
B |
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
rel. / 0…0.2bar(0…20kPa) | |
|
│
|
│
|
│
|
C |
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
rel. / 0…0.4bar(0…40kPa) | |
|
│
|
│
|
│
|
D |
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
rel. / 0…1.0bar(0…100kPa) | |
|
│
|
│
|
│
|
E |
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
rel. / 0…2.5bar(0…250kPa) | |
|
│
|
│
|
│
|
F |
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
rel. / 0…5.0bar(0…500kPa) | |
|
│
|
│
|
│
|
G |
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
rel. / 0…10.0bar(0…1000kPa) | |
|
│
|
│
|
│
|
P |
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
rel. / -1…0.0bar(-100…0kPa) | |
|
│
|
│
|
│
|
Q |
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
rel. / -1…1.5bar(-100…150kPa) | |
|
│
|
│
|
│
|
R |
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
rel. / -1…5.0bar(-100…500kPa) | |
|
│
|
│
|
│
|
S |
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
rel. / -1…10.0bar(-100…1000kPa) | |
|
│
|
│
|
│
|
K |
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
rel. / -0.05…0.05bar(-5…5kPa) | |
|
│
|
│
|
│
|
L |
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
rel. / -0.1…0.1bar(-10…10kPa) | |
|
│
|
│
|
│
|
M |
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
rel. / -0.2…0.2bar(-20…20kPa) | |
|
│
|
│
|
│
|
1 |
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
abs / 0…1.0bar(0…100kPa) | |
|
│
|
│
|
│
|
2 |
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
abs / 0…2.5bar(0…250kPa) | |
|
│
|
│
|
│
|
3 |
┄
|
┄
|
┄
|
┄
|
┄
|
┄
|
abs / 0…5.0bar(0…500kPa) | |
|
│
|
│
|
│
|
│
|
|
|
|
Signal output: | ||||
|
│
|
│
|
│
|
│
|
Z
|
┄
|
┄
|
┄
|
┄
|
┄
|
Two line system, 4-20mA | |
|
│
|
│
|
│
|
│
|
H
|
┄
|
┄
|
┄
|
┄
|
┄
|
Two line system, 4-20mA/HART ® | |
|
│
|
│
|
│
|
│
|
P
|
┄
|
┄
|
┄
|
┄
|
┄
|
Fieldbus | |
|
│
|
│
|
│
|
│
|
F |
┄
|
┄
|
┄
|
┄
|
┄
|
Fundamentals of Fieldbus | |
|
│
|
│
|
│
|
│
|
│
|
|
|
Shell/Protection Level: | ||||
|
│
|
│
|
│
|
│
|
│
|
K
|
┄
|
┄
|
┄
|
┄
|
Plastic casing IP66/IP67 | |
|
│
|
│
|
│
|
│
|
│
|
A |
┄
|
┄
|
┄
|
┄
|
Aluminum shell IP66/IP67 | |
|
│
|
│
|
│
|
│
|
│
|
D |
┄
|
┄
|
┄
|
┄
|
Aluminum shell double chamber IP66/IP67 | |
|
│
|
│
|
│
|
│
|
│
|
8 |
┄
|
┄
|
┄
|
┄
|
Stainless steel (electrolytic polishing) 316L/IP66/IP67 | |
|
│
|
│
|
│
|
│
|
│
|
P |
┄
|
┄
|
┄
|
┄
|
PUR axial output cable IP68, split plastic shell IP65 | |
|
│
|
│
|
│
|
│
|
│
|
W |
┄
|
┄
|
┄
|
┄
|
Stainless steel double chamber casing/IP66/IP67 | |
|
│
|
│
|
│
|
│
|
│
|
R |
┄
|
┄
|
┄
|
┄
|
Plastic dual chamber casing/IP66/IP67 | |
|
│
|
│
|
│
|
│
|
│
|
│
|
|
Connecting cables/cable sealing covers/connecting plugs: | ||||
|
│
|
│
|
│
|
│
|
│
|
│
|
M
|
┄
|
┄
|
┄
|
M20x1.5/Yes/No | |
|
│
|
│
|
│
|
│
|
│
|
│
|
N
|
┄
|
┄
|
┄
|
1/2NPT/None/None | |
|
│
|
│
|
│
|
│
|
│
|
│
|
│
|
Indication/Adjustment Module (PLISCOM): | ||||
|
│
|
│
|
│
|
│
|
│
|
│
|
│
|
X |
┄
|
┄
|
not have | |
|
│
|
│
|
│
|
│
|
│
|
│
|
│
|
A |
┄
|
┄
|
install | |
|
│
|
│
|
│
|
│
|
│
|
│
|
│
|
│
|
Accuracy level: | |||
|
│
|
│
|
│
|
│
|
│
|
│
|
│
|
│
|
M |
┄
|
0.075% | |
|
│
|
│
|
│
|
│
|
│
|
│
|
│
|
│
|
E |
┄
|
0.10% | |
|
│
|
│
|
│
|
│
|
│
|
│
|
│
|
│
|
S |
┄
|
0.20% | |
|
↓
|
↓
|
↓
|
↓
|
↓
|
↓
|
↓
|
↓
|
↓
|
|
||
|
BR52.
|
##
|
##
|
#
|
#
|
#
|
#
|
# | # | # |
|
: Select model |
VEGA pressure sensor (VEGABAR 52) pressure transmitter from Germany