Slurry density meter - Liquid online density meter - Differential pressure online density meter - Intelligent online density meter - Remote transmission density meter-Jiangsu Sanfeng Instrument TechnologyQuality first for limited companies, Integrity based, excellent service. We provide product consultation, selection guidance, pricing and other services to our customers. We welcome customers to place orders! :0517-0517-86992223Mobile phone: 18915199993 Product Description:Slurry online density meterIt can measure the density of various liquids or liquid mixtures online. It can be widely used in the petrochemical industry for petroleum, refining, oil blending, and oil-water interface detection; Used in the food industry for production sites such as grape juice, tomato juice, fruit syrup, vegetable oil, and soft drink processing; Dairy industry; Paper industry; Testing of black, green, white, and alkaline solutions; Alcohol content in brewing; Chemical urineTesting of the density of vegetables, cleaning agents, ethylene glycol, acid and alkali, and polymers. It can also be applied to industries such as mining mud, saltwater, potash, natural gas, lubricants, biopharmaceuticals, etc.
The main features of the slurry density meter are: 1. It adopts an integrated structure of a two-wire transmitter, with no moving parts and simple maintenance. 2. It has a four and a half digit LCD display. 3. It is easy to install and use, and can display readings when inserting liquid. 4. It is suitable for installation in pipelines and tanks for fluid or static liquids. 5. The temperature and density parameters can be alternately displayed for industry standard density conversion. 6. It can continuously measure liquid density online without process interruption and can be directly used for production process control. 7. All parts in contact with liquid are made of stainless steel materials for several media, which is safe; Hygiene. 8. This medium is safe and can be used in hazardous environments; Sanitary type can be installed on food production sites
Slurry density meterTECHNICAL INDEX
1. 4-20mA current output Select digital signal (HART protocol)
2. 16~30VDC power supply Recommend using 24VDC
3. Density range 0-2 grams per cubic centimeter; 0-3 grams per cubic centimeter
4. Accuracy of 0.001 grams per cubic centimeter
5. Resolution 0.0005 grams per cubic centimeter
6. Temperature range 0-100 ℃
7. Temperature accuracy 0.2 ℃
8. Environmental temperature -10~60 ℃
9. Humidity range 0-90%
Ordering precautions
1. The density meter diaphragm is the weakest part. Please do not let sharp objects impact the diaphragm and cause damage.
2. The MD3051 online densitometer can theoretically measure concentration based on different media. Please use the method to convert the concentration result according to the on-site situation.
3. When selecting, please ask the manufacturer and provide on-site installation information, and indicate it when signing the contract.
4. If calibration or adjustment is required, please contact the manufacturer.
Selection instructions for slurry density meter:
model |
Specification code |
describe |
SF-MD3051 |
··············· |
Industrial online density meter |
Installation and appearance |
A··············· |
Direct installation type |
B··············· |
Elbow type |
|
C··············· |
Side mounted |
|
Membrane box (sensor) |
5··············· |
500mmthe above |
10··············· |
1000mm |
|
15··············· |
special requirements |
|
Distance between flange sensors |
M··············· |
300mm |
F··············· |
User defined distance |
|
measuring range |
1··············· |
0~1 can/cubic centimeter |
2··············· |
0~2 can/cubic centimeter |
|
3··············· |
0~3 can/cubic centimeter |
|
mounting flange |
H6··············· |
DN65 |
H8··············· |
DN80 |
|
H10··············· |
DN100 |
|
Typical example of flange installation: MD3051A5M1H8 | ||
The following is the default configuration: | ||
Display header |
··············· |
LCD intelligent display table |
output signal |
··············· |
4~20mA |
Input power supply |
··············· |
24VDC |
Membrane structure material |
··············· |
316 stainless steel (other available for order) |
Transport packaging |
··············· |
WOODEN CASE |
Installation matters
1: Direct type The minimum distance between the sensors of the online liquid density meter is 200mm, with a diameter of 50mm. The installation size on site cannot be smaller than these dimensions. If a curved density meter is selected, please measure the flange and length dimensions that can be inserted into the pipe
2: The on-site liquid must be kept at least two measuring sensors, and the distance from the flange to * sensors can be selected
3: During pipeline installation, it is necessary to allow the liquid to enter from below the sensor at Zui, or from above the sensor at Zui. Do not enter the liquid from the middle. When installing pipelines for liquid flow, at least 30CM of liquid buffer distance should be left at the valve or elbow part of the pipeline.
4: The red flange matching part of the installation diagram is provided for installation by the user. If matching flanges are needed, please specify when placing an order
5: Equipped with a power supply of 24V DC output 4-20mA signal. If a secondary meter is required, the 24V "+" should be connected
Connect the "+" pole behind the density meter, connect the "+" current signal to the "-" pole of the density meter, and short-circuit the 24V "-" and current signal terminals "-" on the secondary meter
6: If there are corrosive liquids outside the site environment, please take protective measures. If there is a risk of lightning strikes, please install grounding devices in the surrounding area.
7: When disassembling for cleaning, please ensure that the sensor diaphragm is not damaged by collision or other factors.
8: Please do not exceed 5M in heightpUse under situation a.
9: If adjusting the range requires the use of a handheld device, please consult the manufacturer for technical issues
Slurry density meter
After sales commitment:
1. Unconditional after-sales service (installation and debugging guidance, troubleshooting).
2. If there are quality problems with the products sold by our company within one year (excluding human error, selection errors, unsatisfactory working conditions, and easily damaged products), we are responsible for free repair and replacement.
3. On site service: Surrounding areas 48Respond within hours.
Jiangsu Sanfeng FriendshipTip: The regular product delivery period is 1-3Within one working day, special specifications need to be consulted and confirmed. Inquire! We will serve you wholeheartedly!