Brief description: The pipeline intelligent online densitometer is a two-wire densitometer mainly used for industrial process control. The pipeline online densitometer generates a corresponding 4-20mA signal based on the concentration and density, which can be remotely calibrated and monitored through digital communication.

Product Details

Pipeline type online density meter - Vertical pipeline type online density meter - Vertical pipeline onlineDensity meter - Intelligent pipeline online density meter - Differential pressure online density meter - Pipeline online density meter - Intelligent remote transmission density meter-Jiangsu Sanfeng Instrument Technology Co., Ltd. puts quality first, Integrity based, excellent service. We provide product consultation, selection guidance, pricing and other services to our customers. We welcome customers to place orders! : Mobile phone/:

MD-The 3051 series online densitometer can measure the density of various liquids or liquid mixtures online. It can be widely used in the petrochemical industry for petroleum, refining, oil blending, and oil-water interface detection; Used in the food industry for production sites such as grape juice, tomato juice, fruit syrup, vegetable oil, and soft drink processing; Dairy industry; Paper industry; Testing of black, green, white, and alkaline solutions; Alcohol content in brewing; Testing of urea, cleaning agents, ethylene glycol, acidity and alkalinity, and polymer density in the chemical industry. It can also be applied to industries such as mining mud, saltwater, potash, natural gas, lubricants, biopharmaceuticals, etc.

Pipeline type intelligent online density meterMain features: 1. Two wire transmitter with integrated structure, easy to maintain without moving parts. 2. Four and a half digit LCD display. 3. Easy to install and use, reading can be displayed by inserting liquid. 4. Suitable for installation in pipelines and tanks for fluids or stationary liquids. 5. Temperature and density parameters can be alternately displayed for industry standard density conversion. 6. Continuous online measurement of liquid density without process interruption, can be directly used for production process control. 7. All parts in contact with liquids are made of stainless steel materials for several media, ensuring safety; Hygiene. 8. This medium is safe and can be used in hazardous environments; Sanitary type can be installed on food production sitesPipeline type intelligent online density meterTECHNICAL INDEX

1. 4-20mA current output Select digital signal (HART protocol)

2. 16~30VDC power supply Recommend using 24VDC

3. Density range 0-2 grams per cubic centimeter; 0-3 grams per cubic centimeter

4. Accuracy of 0.001 grams per cubic centimeter

5. Resolution 0.0005 grams per cubic centimeter

6. Temperature range 0-100 ℃

7. Temperature accuracy 0.2 ℃

8. Environmental temperature -10~60 ℃

9. Humidity range 0-90% Ordering precautions

1. The density meter diaphragm is the weakest part. Please do not let sharp objects impact the diaphragm and cause damage.

2. The MD3051 online densitometer can theoretically measure concentration based on different media. Please use the method to convert the concentration result according to the on-site situation.

3. When selecting, please ask the manufacturer and provide on-site installation information, and indicate it when signing the contract.

4. If calibration or adjustment is required, please contact the manufacturer.

Selection instructions:

model

Specification code

describe

SF-MD3051

···············

Industrial online density meter

Installation and appearance

A···············

Direct installation type

B···············

Elbow type

C···············

Side mounted

Membrane box (sensor)

5···············

500mmthe above

10···············

1000mm

15···············

special requirements

Distance between flange sensors

M···············

300mm

F···············

User defined distance

measuring range

1···············

01 can/cubic centimeter

2···············

02 can/cubic centimeter

3···············

03 can/cubic centimeter

mounting flange

H6···············

DN65

H8···············

DN80

H10···············

DN100

Typical example of flange installation: MD3051A5M1H8

The following is the default configuration:

Display header

···············

LCD intelligent display table

output signal

···············

4~20mA

Input power supply

···············

24VDC

Membrane structure material

···············

316 stainless steel (other available for order)

Transport packaging

···············

WOODEN CASE

3: Installation matters

1:Pipeline based intelligenceOnline density meterThe minimum spacing between the sensor parts is 200mm, with a diameter of 50mm. Installation on site cannot be smaller than these dimensions. If a curved density meter is selected, please measure the flange and length dimensions that can be inserted into the pipe 2: The on-site liquid must be kept at least two measuring sensors, and the distance from the flange to * sensors can be selected

3: During pipeline installation, it is necessary to allow the liquid to enter from below the sensor at Zui, or from above the sensor at Zui. Do not enter the liquid from the middle. When installing pipelines for liquid flow, at least 30CM of liquid buffer distance should be left at the valve or elbow part of the pipeline.

4: The red flange matching part of the installation diagram is provided for installation by the user. If matching flanges are needed, please specify when placing an order

5: Equipped with a power supply of 24V DC output 4-20mA signal. If a secondary meter is required, the 24V "+" should be connected

Connect the "+" pole behind the density meter, connect the "+" current signal to the "-" pole of the density meter, and short-circuit the 24V "-" and current signal terminals "-" on the secondary meter

6: If there are corrosive liquids outside the site environment, please take protective measures. If there is a risk of lightning strikes, please install grounding devices in the surrounding area.

7: When disassembling for cleaning, please ensure that the sensor diaphragm is not damaged by collision or other factors.

8: Please do not exceed 5M in heightpUse under situation a.

9: If adjusting the range requires the use of a handheld device, please consult the manufacturer for technical issues