Photoelectric direct reading valve controlled water meter

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Introduction: The photoelectric direct reading valve controlled water meter adopts photoelectric direct reading technology to read character wheel data. Compared with traditional pulse meters, it can reduce the reading error to zero. It is an electronic remote water meter with zero electromechanical conversion error in automatic meter reading systems, and adopts a low-power design. It usually does not require power supply and only needs to be powered during meter reading or valve operation.
Product Details

application

Product use

The photoelectric direct reading valve controlled water meter adopts photoelectric direct reading technology to read the character wheel data. Compared with traditional pulse meters, it can reduce the reading error to zero. It is an electronic remote water meter with zero electromechanical conversion error in automatic meter reading systems, and adopts a low-power design. It usually does not require power supply and only needs to be powered during meter reading or valve operation.

Product Features

PRODUCT FEATURES



This series of remote water meters is a dry structure

Easy to read, able to maintain clarity for a long time

Adopting optoelectronic coding passive direct reading technology

Valves can control water usage

Technical Parameter

TECHNICAL PARAMETER


Product model: LXS-15-25 FK
Working voltage: DC 36V
Meter reading working current ≤ 9.0mA
Static working current ≤ 1.3 mA


Valve on/off bus current ≤ 50 mA
Valve on/off motor valve input current ≤ 30 mA
Water temperature: 0.1 ℃~+45 ℃
Humidity: 0-95% RH


Storage temperature: -25 ℃~+65 ℃
Temperature rating: T50 (cold water) T90 (hot water)
Maximum allowable water pressure: 1 MPa
Maximum pressure loss: 0.063 Mpa


Valve type: motor valve


Communication method with the upper computer: M-bus fieldbus

Communication transmission rate: 2400 baud




Communication protocols: DL/T645, CJ/T 188, and internal protocols

(or user specified protocol)

Maximum communication transmission distance: 300m;

(Communication line specification AVVR2 × 0.75)



Single meter valve opening/closing time: 8S

Bus pin ESD protection exceeds 10kV

short circuit current protection

Protection against bus open circuit, short circuit, idle and other faults




Traffic parameters

FLOW PARAMETERS

Model

Nominal diameter

DN(MM)

accuracy

grade

Overload flow Q4
Common traffic Q3
Boundary flow Q2
Minimum flow Q1
M³/H
LXS-15FK
15 level 2 3.125
2.5
0.050
0.030
LXS-20FK
20 level 2
5.00
4.0
0.080
0.050
LXS-25FK
25 level 2
7.875
6.3
0.128
0.080
LXS-40
40 level 2
20
16
0.320
0.200
Note: Maximum allowable error
The maximum allowable error in the low zone, including the minimum flow rate (Q1) and excluding the boundary flow rate (Q2), is ± 5%
The maximum allowable error in the high zone, including the boundary flow rate (Q2) and the maximum flow rate (Q4), is ± 2%