E-mail
jesman_sales@yeah.net
-
Phone
13371682585
-
Address
0705, 7th Floor, Building 10, No.1 Courtyard, Wuliqiao Second Street, Chaoyang District, Beijing
Beijing Jessman Technology Co., Ltd
jesman_sales@yeah.net
13371682585
0705, 7th Floor, Building 10, No.1 Courtyard, Wuliqiao Second Street, Chaoyang District, Beijing

|
Application scope
|
Power frequency(5Hz-100KHz)
|
RF (Radio Frequency)(100KHz-40GHz)
|
|
High voltage transmission and transformation systems, distribution rooms, induction furnaces, subways, trams and other workplaces
|
Various types of long wave, medium wave, short wave, and microwave radiation, including:
Workplaces with electromagnetic radiation, such as mobile phone stations, medical equipment, radar, satellite communication, TV antennas, pager stations, heat sealers, drying equipment, televisions, computers, etc
|
|
|
Instrument characteristics
|
*5Hz-100KHz spectrum analysis function* 0.05v/m-1000v/mLarge dynamic electric field measurement range with optional probe
|
|
|
*Electromagnetic field integrated enhanced probe* 8100A data storage table * Free software updates
|
||
|
*Proactively identify the frequency of pollution sources * Three types of averaging modes are available: arithmetic mean, RMS mean, and spatial mean
|
||
|
Random accessories
|
hostPMM8053B field strength measurement main unit, rechargeable battery, charger, data download software,RS232 interface, dedicated software package
|
|
|
Extended functionality
|
Scalable connection16 probes for point monitoring (optional), expandable to connect to GPS system
|
|
|
Options
|
10m20m, 40m, and 80m fiber optic cables, tripod, optical data converter, calibrator, telescopic pole, remote control software
|
|
|
model
|
simple parameters
|
Measurement function characteristics
|
|
low frequencyelectricity-Magnetic fieldmeasureProbe selection (power frequency measurement)
|
||
|
EHP-50C
|
electricity-Magnetic field: 5Hz-100KHz, isotropic
Range:0.01v/m-100Kv/m,1nT-10mT
Spectrum analysis function,7 options with fixed width
|
Low frequency electricity-The magnetic field dedicated measurement probe has powerful spectral analysis capabilities and is currently the world's most advanced power frequency measurement and analysis probe. It can solve the harmonic problems in power frequency measurement and identify and measure low-frequency broadband radiation signals. Independent 24-hour continuous monitoring function.
|
|
Selection of RF measurement electric field probe
|
||
|
EP-330
|
Frequency:100K-3GHz
Range:0.3-300v/m, isotropic
|
Measure frequency coverage of signals such as radio, television, radio, mobile phone stations, microwave ovens, induction cookers, etc., with measurement accuracy0.3v/m is suitable for better environmental monitoring and product quality testing requirements.
|
|
EP-300
|
Frequency:100K-3GHz
Range:0.1-300v/m, isotropic
|
Measure frequency coverage of signals such as radio, television, radio, mobile phone stations, microwave ovens, induction cookers, etc., with measurement accuracy0.1v/m, suitable for environmental background investigation, environmental monitoring, and product quality testing requirements.
|
|
EP-105
|
Frequency:100K-1GHz
Range:0.05-50v/m, isotropic
|
High precision probe, measuring frequency coverage of long wave navigation radar, radio, television, radio900M mobile phone station and other signals, with a measurement accuracy of 0.05v/m, mainly for environmental background investigation.
|
|
EP-301
|
Frequency:100K-3GHz
Range:1-1000v/m, isotropic
|
Measure frequency coverage of signals such as radio, television, radio, mobile phone stations, microwave ovens, induction cookers, etc., with measurement accuracy1v/m, suitable for general environmental monitoring and product quality testing requirements.
|
|
EP-183
|
Frequency:1M-18GHz
Range:0.8-800v/m, isotropic
|
The measurement frequency covers signals from radio, television, radio, mobile phone stations, radar, satellites, etc., mainly targeting common meteorological station radars, high-frequency microwave communication stations, navigation radars, satellites, and other millimeter wave signals.
|
|
EP-408
|
Frequency:1M-40GHz
Range:0.8-800v/m, isotropic
|
The measurement frequency covers signals from radio, television, radio, mobile phone stations, radar, satellites, etc., mainly targeting millimeter wave signals from common meteorological station radars, high-frequency microwave communication stations, navigation radars, satellites, and special-purpose radars.
|
|
EP-33M
|
Frequency:700M-3GHz
Range:0.3-300v/m, isotropic
|
Specially designed for measuring various mobile communication stations. Not affected by signals such as radio and television.
|
|
EP-44M
|
Frequency:100K-800MHz
Range:0.25-300v/m, isotropic
|
Specially designed for various radio, television, radio and other signals, unaffected by signals from various mobile communication stations.
|
|
Selection of RF measurement magnetic field probe
|
||
|
HP-102
|
Frequency:30M-1GHz
Range:0.01-20A/m, isotropic
|
Measure the frequency coverage of medium wave and short wave signals in broadcasting, television, radio, and other fields. Mainly used for near-field measurement.
|
|
HP-032
|
Frequency:100K-30MHz
Range:0.01-20A/m, isotropic
|
Measure the frequency coverage of broadcast long and medium wave signals.
|
|
|
electricity a place where people gather
|
magnetism a place where people gather
|
|
Frequency range
|
5 Hz – 100 kHz
|
|
|
measure Cheng
|
0.01 V/m – 100 kV/m
|
1 nT – 10 mT
|
|
cross year
|
200 kV/m
|
20 mT
|
|
dynamic range
|
> 140 dB
|
|
|
display resolution
|
0.01 V/m
|
1 nT
|
|
quickMinlinear measure
|
0.1 V/m
|
1 nT
|
|
Optional bandwidth
|
100 Hz, 200 Hz, 500 Hz, 1 kHz, 2 kHz, 10 kHz, 100 kHz
|
|
|
school accurate
|
Internal E2PROM
|
|
|
Temperature response
|
0.05 dB/°C
|
|
|
8053-CALcalibrator
pass through8053Main instrument charging, used for detection8053instrumentX、Y、ZAxis input function.
Standard reading:57.7v/m
Accuracy:+/- 2%
|
|
|
To avoid the influence of personnel during monitoring, PMM provides a good solution by connecting 10-80 meters of optical fiber between the 8053B main instrument and probe through OR-02 optical data repeater
|
OR-02Optical data repeater
|
|
8053-GPSAutomatic Global Positioning System
The 8053-GPS automatic global positioning system can be directly connected to the 8053 main instrument through optical fiber, or connected to the SB-04 data converter to display the coordinates of the positioning point. Use 8053-SW02 to store coordinates and field strength values
|
|
|
8053-SW02Data Acquisition Software
*Multiple data analyses can be conducted while measuring and storing data
*The chart displays the stored data in the recorder.
*Identify markers for point by point data analysis
*Comparison between measured values and user set limits
*Real time data chart display
|
|
Frequency range
|
|
|
Frequency range
|
5 Hz - 40 GHz
|
|
dynamic range
|
>120 dB
|
|
one position
|
V/m, kV/m, mW/cm², W/m², A/m,mT, mT;
|
|
LCDDisplay data
|
|
|
Measurements
|
X. Absolute values, percentages, and total values in the Y and Z directions
|
|
time between
|
Built in clock time display
|
|
try to find out head
|
Display probe model and calibration time
|
|
Bar chart
|
Simulated intensity display (linear, logarithmic) corresponding to real-time measurement values
|
|
alarm threshold
|
|
|
Measurement function
|
|
|
sample time
|
150 ms with 80 Hz filter, 250 ms with 40 Hz filter, 450 ms with 20 Hz filter 900 ms with10 Hz filter
|
|
store store up
|
Single file storage of 32700 measurement data (8100 multi file storage of measurement data)
|
|
report guard against
|
Users can set thresholds. Sound and screen flashing signal alarm
|
|
work ability
|
*Small value, * large value, and average value (RMS average and Avg average are optional for users)
|
|
Average Mode
|
Arithmetic mean, root mean square (RMS) mean, manual and spatial mean
|
|
average time
|
32 sampling points are averaged, with options of 30 seconds, 1 minute, 2 minutes, 3 minutes, 6 minutes, 10 minutes, 15 minutes, and 30 minutes
|
|
data acquisition
|
Sampling mode (1.10-900 seconds/sampling), data variable values, threshold exceeded, 1 second, 10 seconds, 6 minutes -1 minute, 6 minutes -6 minutes
|
|
(Recorder)
|
6-minute average, manual, spectrum analysis (when using EHP-50A probe)
|
|
Time domain display
|
*Fast mode, 1 minute, 2 minutes, 10 minutes, 30 minutes, 60 minutes settings
|
|
General Instructions
|
|
|
apparent show
|
72x72mm LCD display screen with 128x128 pixels, RS232 interface (using cable or fiber optic)
|
|
built-in battery
|
Rechargeable NiMH battery (5 x 1.2 V)
|
|
Usage time
|
Normal mode for 20 hours, power-saving mode for 40 hours (power-saving mode: display screen turned off)
|
|
charging time
|
<4 hours (can be used for 1 hour after 15 minutes of charging)
|
|
Support external power supply
|
AC power, 10 - 15 V, I ≈ 500 mA
|
|
connect opening
|
RS232 interface (can be used for remote control, calibration, and program updates in memory)
|
|
Software/Memory Programs
|
It can be upgraded through the Internet.
|
|
self inspect
|
Self check all functions during startup
|
|
Automatic calibration
|
The probe is equipped with an E ² PROM for real-time automatic zeroing
|
|
Measuring temperature
|
From -10 to+40 ° C
|
|
Storage temperature
|
From -20 to+70 ° C
|
|
Size (WxHxD)
|
108 x 240 x 50 mm
|
|
weight measure
|
1070g
|