Multi functional cable hot repair equipment

NegotiableUpdate on 02/11
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Multi functional cable hot repair equipment with an area of 1.5-185 square millimeters, a hot repair length of 600mm, a working surface height of 750mm, a maximum mold clamping pressure of 5T, and an adjustable mold temperature range of 0-300 ℃. It is equipped with various types of cable hot repair molds and has complete supporting facilities
Product Details

Multi functional cable hot repair equipmentFeatures:

1. This device consists of a control section (low voltage) and a high voltage rectification, discharge, and testing section. There is sufficient safety space between high and low pressure, as well as between high and low pressure and the casing

Between.

2. To ensure the safety of equipment and personnel, a dedicated person must operate with a key before high-voltage starting.

3. During each inspection or testing of the cable, it can be ensured that the high voltage gradually increases from zero position, with high and low voltage limit shapes. The process of increasing or decreasing voltage is carried out by buttons

Control, smooth voltage rise and fall rate, safe and easy operation.

4. The DC withstand voltage test time can be automatically controlled by a digital system (or manually controlled), and the test time is accurate and reliable.

5. The leakage current can be measured at any time according to the needs of the withstand voltage testing process.

6. The equipment has overcurrent and short-circuit protection, as well as startup warning and overcurrent protection.

7. There are power switches, high-voltage start, high-voltage stop, boost, buck and other switches or buttons on the control panel, as well as voltage withstand test digital time timing relays.

8. There are high voltage, leakage current, and low voltage total current measuring meters on the display panel, equipped with indicator lights for power supply, high voltage, timing, and curved observation of ball gap discharge

Check the window, etc.

9. Equipped with high-voltage discharge rods for discharging after each inspection or test to ensure safety, and there is a grounding mark at the bottom of the box.

Instructions for using multifunctional cable hot repair equipment
1. Use a screwdriver to adjust the mechanical zero point of the temperature indicator to the ambient temperature scale, and adjust the constant temperature indicator pin to the temperature scale required by the rubber patch basketball team.
2. Adjust the timer switch. The timer switch is equipped with "ON" on, "OFF" off, and a time scale. Do not use a timer. Turn the switch knob to the "ON" position. To use a timer, turn the switch knob clockwise to the desired position, and then return to the time scale you have selected.
3. When an electric bell alarm is required, turn the knob to the on position. When no electric bell alarm is required, turn it to the off position.
4. Rotate the power switch, the electrical heating system starts to heat up, and the green light is on at this time; When the temperature reaches the desired level, the instrument relay opens, causing the AC contactor to cut off the power supply to the heating system, and then the timer switch also opens. At this time, the red light is on and the electric bell rings. The staff should promptly turn off the electric bell switch.