Welcome Customer !

Membership

Help

Beijing Liyangtaike Technology Co., Ltd
Custom manufacturer

Main Products:

intelligent-mfg>Products

Beijing Liyangtaike Technology Co., Ltd

  • E-mail

    leonlok@163.com

  • Phone

  • Address

    1011, 10th Floor, Block A, Building 1, Xirong Ge Building, No. 138 Changhua Road, Haidian District, Beijing

Contact Now

Multi component gas analyzer MCA03

NegotiableUpdate on 08/20
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Direct measurement, no conversion required, can simultaneously measure up to 8 gases (7 infrared gases+O2). The combination of gas filtering correlation method and single beam dual wavelength measurement technology is suitable for measuring hot and humid sample gases. The sampling pipeline, sampling air pump, and sample measurement chamber are all heated, with temperature control at 185 ℃ and good stability. The low maintenance workload meets the requirements of 40 CFR Part 60 and 75 of the US Federal Regulations

Product Details

Application fields:

power plant

Garbage Disposal Incinerator

cement plant

chemical plant

pharmaceutical factory

paper mill

Glass manufacturing?

Typical features of multi-component gas analyzer MCA03:

Direct measurement without conversion

Can simultaneously measure up to 8 gases (7 infrared gases+O2)

Combining gas filtering correlation method with single beam dual wavelength measurement technology

Suitable for measuring hot and humid sample gases, the sampling pipeline, sampling air pump, and sample measurement chamber are all heated and the temperature is controlled at 185 ℃

Good stability, low maintenance workload

Symbols required by 40 CFR Parts 60 and 75 of the United States Federal Regulations

Technical parameters of multi-component gas analyzer MCA03

Measurement principle: gas filtering correlation method; Single beam dual wavelength technology; Zirconia (optional)

Measurement components: CO/NO/NH3/HCL/N2O/CH4/SO2/NO2/H2O/CO2/O2

Up to 7 types of infrared gas components+O2 (see table below for details)

Sample Room: Optical channel length of 6 meters; The temperature is controlled at 185 ℃, with a maximum of 200 ℃

Response time: 10 seconds

Sampling flow rate: 2-7 liters/minute

Detection limit: 1% of the maximum small range

Accuracy: ± 2% of the full range

Display: LCD monitor

Function keys: numeric and arrow keys, dustproof and waterproof

Signal output: 1 RS232 communication interface

Up to 8 analog signal outputs of 0/4-20 mA;

3 relay signal outputs: used for analyzer malfunction, maintenance, and repair indication

Environmental temperature: 0~40 ℃

Power supply: 220VAC/50Hz

Size: 19 "rack mounted, approximately 22cm in height, 48cm in width, and 58cm in depth

Weight: 25Kg