summary:
The high-temperature absolute humidity sensor 303 from H2O Company in the United States uses sensor technology for precise humidity measurement under high-temperature and harsh conditions. In situ measurement, heating probe, and special ceramic surface filter ensure that the high-temperature absolute humidity sensor 303 is suitable for high dust content and high humidity environments. The sensor is always heated to a constant temperature above the process temperature, effectively avoiding condensation on the surface and inside of the probe.
The high-temperature absolute humidity sensor 303 from H2O Company in the United States has superior accuracy, resolution, and dynamic high humidity measurement. No sampling or gas adjustment is required during measurement, resulting in low maintenance and significant cost savings for users.
The high-temperature absolute humidity sensor 303 from H2O Company in the United States directly measures water molecules without any interference or pollution from other background gases.
Application fields:
Drying process control (spray dryer optimization; direct fire drying; conveyor belt dryer; continuous hot drying exhaust gas control; vacuum drying; steam drying, etc.)
Dew point control (chimney and flue dew point, prevention of flue corrosion due to condensation)
Drying and purification (reducing pressure loss caused by bag breakage; energy conservation and emission reduction, shortening downtime; flue gas desulfurization control)
Measurement of flue gas humidity (combustion process control; boiler leak detection; nitrogen oxide removal process control) and adjustment of electrostatic precipitator (humidification to enhance particle collection; humidity control to avoid corrosion machine blockage)
Blast furnace combustion process (humidity interference monitoring; prevention of bag blockage and shutdown; control of water spray system)
Chemical manufacturing (silicone, sodium chloride, ceramics, magnetic coatings, etc.)
Typical features:
In situ direct measurement
The temperature can reach up to 450 ℃
Heated probe
0~100% full scale
Suitable for high dust conditions
High temperature resistant ceramic filter
Not disturbed by background atmosphere
No moving parts
maintenance-free
No need for further calibration
4~20mA isolated signal output
NEMA 4X protection level
Measurement principle:
Water molecules are formed through special covalent bonds between hydrogen and oxygen atoms, and the electrons between hydrogen and oxygen atoms are not equal (oxygen atoms have more electrons). Due to the unequal number of electrons carried, the electric force is asymmetric, resulting in the formation of dipole molecules. Water molecules have two positively charged hydrogen atoms and one negatively charged oxygen atom. The water molecules in the charging room will align with the electric field due to their dipole characteristics, and the linearity depends on the force of thermal imbalance (inversely proportional to temperature) and the electric field force. The energy consumed by arranging water molecules can be calculated from the temperature of thermal imbalance and the number of polar molecules in the electric field. Therefore, it is possible to determine the number of polar molecules with known temperature in the electric field by using highly sensitive current measuring components to measure the energy consumption in the electric field. Water molecules have a very unique relationship with dipole moment and molecular weight, therefore, a frequency of 20KHz is used to specify water molecules without interference from other dipole molecules. Water vapor diffuses into the capacitor through the membrane filter, and the measured value is proportional to the number of water molecules in the capacitor. The volume of the sensor chamber is fixed, therefore, a linear output of the weight of water molecules per unit volume is obtained (measured value in g/m3 or vol.%).
Technical Specifications:
Measurement probe
Measurement range: 0~100% vol
0~50%Vol.
0~30%Vol.
Sample gas temperature: maximum 450 ℃
Sample gas pressure: maximum 1000Psi (68bar)
Response time: T95 approximately 30 seconds
Measurement error: The typical error is ± 0.25% vol. (depending on the specific range and temperature)
Probe material: 316 stainless steel, nickel chromium alloy, Al2O3 ceramic PTFE
Installation flange: 4 '150 lb ANSI/NW100 ND15 DIN
Electronic part
Environmental temperature: -20 ℃~+65 ℃
Environmental humidity: maximum 80% RH, non condensing
Shell material: aluminum, polyethylene coating
Protection level: IP67
Power supply: 230VAC ± 12V, 5A
Signal output: 4~20mA (250 ohms, isolated)