Welcome Customer !

Membership

Help

Yangzhou Sudian Electric Co., Ltd
Custom manufacturer

Main Products:

intelligent-mfg>Products

Leakage current DC high-voltage generator

NegotiableUpdate on 03/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Leakage current DC high-voltage generator (DC high-voltage generator). By applying AIPWM technology, the inaccurate linearity of PWM technology has been adjusted, resulting in a significant improvement in instrument accuracy. And it adopts AI technology to set overvoltage protection and overcurrent protection on the screen, replacing the problem of digital dial switches that can only set voltage values but cannot set current values and voltage drift.
Product Details

1、 Product feature description:

1. Leakage current DC high-voltage generator (DC high-voltage generator). By applying AIPWM technology, the inaccurate linearity of PWM technology has been adjusted, resulting in a significant improvement in instrument accuracy. And it adopts AI technology to set overvoltage protection and overcurrent protection on the screen, replacing the problem of digital dial switches that can only set voltage values but cannot set current values and voltage drift. 0.75UDC1mA function button, convenient for testing zinc oxide lightning arrester, accuracy 1. Added timing function under arbitrary voltage and current, as well as total time T1 and segmented timing T2 functions. The instrument has added perpetual calendar and time functions.

2. The chassis adopts a portable chassis, which is easy to carry.

3. By using AIPWM technology, the inaccurate linearity of PWM has been adjusted, resulting in a significant improvement in accuracy. Ripple factor 0.2.

4. AI zinc oxide lightning arrester and oil immersed transformer measurement function. You can directly save the experimental report with an accuracy of 1. Maintain manual 0.75UDC1mA.

5. And AI technology is used to set overvoltage protection and overcurrent protection, replacing the problem of digital dial switches that can only set voltage values but cannot set current values and voltage drift. Error 16, full range smooth voltage regulation, voltage regulation accuracy 1, stability 1, voltage and current error 1 ± 1 word

7. Equipped with total time T1 and segmented timing T2, as well as timing function under any voltage and current.

8. The instrument has added perpetual calendar and time functions, and the experimental report includes time and date.

2、 Product nickname:

Leakage current DC high voltage generator, high voltage generator, intermediate frequency DC high voltage generator, high voltage DC generator, DC high voltage generator, portable DC high voltage generator, high-frequency DC high voltage generator, AC/DC high voltage generator, DC high frequency generator.

3、 Product Usage:

The leakage current DC high voltage generator GH-6301C high-frequency DC high voltage generator adopts pulse width modulation AIPWM technology and applies AIPWM technology to adjust the inaccurate linearity of PWM technology, resulting in a significant improvement in instrument accuracy. And it adopts AI technology to set overvoltage protection and overcurrent protection on the screen, replacing the problem of digital dial switches that can only set voltage values but cannot set current values and voltage drift. It has output that is not affected by power grid fluctuations, and has protection measures such as zero position, overcurrent, breakdown, and overvoltage. The overcurrent, breakdown, and overvoltage protection circuits can quickly operate, effectively ensuring the safety of equipment and personnel The instrument is an instrument that provides a high voltage direct current source. Before using a high-frequency direct current high voltage generator, the instrument must be reliably grounded The voltage and current meters of the high-frequency DC high-voltage generator are both digital displays, with a voltage resolution of 0.1kV and a current resolution of 0.1uA. The voltage meter on the control box directly displays the voltage value applied to the load test sample, without the need for an external voltage divider during use, and the wiring is simple. The instrument has high and low voltage ends for measuring leakage current, and the high voltage end is displayed with a circular shielded digital meter, which is not afraid of discharge shock and has good anti-interference performance, suitable for on-site use.

4、 Product Technical Parameters:

rule grid

Technical Specifications

60/2-10

120/2-10

120/2-10

250/2-5

120/300

3/2

its it

wait level

output voltage(kV)

60

120

120

250

120/300

600800kVWaiting for the contract

Customized.

output current(mA)

2-10

2-10

2-10

2-5

2-5

output power(W)

120-600

240-1120

400-1120

500-1250

600

charging current(mA)

3.0

3.0

3.0

3.0

4.5/3.0

Chassis weight(kg)

4.3

4.3

4.4

4.5

8.1

Height of pressure doubling cylinder(mm)

Φ80

×500

Φ80

×770

Φ110

×770

Φ110

×820

Φ110

×1350

Double pressure weight(kg)

6.3

9.8

12

7.6

12.6

High voltage polarity

negative polarity

working power supply

220V±10%

Voltage measurement error

1%±1One byte

Current measurement error

1%±1One byte

Overvoltage setting error

≤1%

0.75Switching error

≤1%

Ripple coefficient

≤0.5%

Voltage stability

random fluctuations.Change in power supply voltage±10%. ≤0.5%

working method

Intermittent use:rated load30minute;1.1Use at double rated voltage:10minute

ambient temperature

-15℃~50

relative humidity

When the temperature is25Not greater than at ℃90%(No condensation)

altitude

1120Below meters