main features
Multiple parameters such as TOC/TIC/TC/TN/δ 13C can be obtained
SWAGELOK product is used as the air circuit connector, which has good sealing performance
Automatic injection measurement, precise injection, saving manpower
Wide measurement range, suitable for multiple types of samples
High concentration gas automatic dilution, automatic online calibration
High reflectivity mirror cavity, high measurement sensitivity
main parameter
Organic carbon and nitrogen measurement module
Automatic injection measurement of TOC/TIC/TC/TN for solid and liquid samples
Zero blank ball valve injection, 120 position injection tray, maximum injection volume of 1.0g
Independent quartz combustion tube and reduction tube, non integrated design, can be replaced separately
Dual tube combustion furnace, heating temperature of 1200 ° C and combustion temperature of 1800 ° C
Gas Separation: Direct TPD Technology Program Heating Adsorption Analysis Separation, Can Analyze Samples with C: N Element Ratios Up to 12000:1
Blow down capture column: N as N2 directly enters the thermal conductivity detector (TCD), while C as CO2 is captured on the TPD column; When the nitrogen peak reaches the baseline, the adsorption column rapidly heats up and CO2 enters the detector; Perfect peak separation, no overlap, automatic optimization of analysis time;
Measurement range: C:0-50mg; N: 0-10mg
High sensitivity thermal conductivity detector (TCD) detection cell
Intelligent injection control module
Equipped with automatic gas collection, dilution, measurement, evacuation, and calibration functions, it connects the organic carbon and nitrogen measurement module with the carbon isotope analysis module, and is used for measuring and calculating the δ 13C values of solid and liquid samples.
Equipped with 2 built-in airbags for alternating circulation of gas collection, with a capacity of ≥ 5L. The instrument records the number of times the airbags are used
Equipped with startup leak detection and automatic dilution function, it can be diluted according to the pre-set concentration range
Communication: RS232/TTL interface
Data storage: Built in SD card
Response time of solenoid valve: < 20ms
Carbon isotope analysis module
Using CRDS laser spectroscopy technology, isotope and gas concentrations are detected by calculating the decay time difference
Simultaneously measure the 13C/12C ratio, CO2 concentration, and CH4 concentration of CO2 gas, and obtain the carbon isotope values of solid or liquid samples by measuring the CO2 gas processed by the organic carbon and nitrogen measurement module
Testing room: Physical length ≤ 30 cm, volume ≤ 40 ml, 3 reflective mirrors in the testing room, forming a circular optical path inside the cavity, mirror reflectivity: ≥ 99.999%
Accuracy of δ 13C (1 σ, 5 min): ≤ 0.1 ‰
Gas concentration accuracy (1 σ, 30s): CO2: ≤ 200ppb (δ 12C), CO2: ≤ 10pppb (δ 13C); CH4: 50ppb+0.05% reading (δ 12C)
Concentration measurement range: CO2:380~2000 ppm; CH4:0~500 ppm
Configuration plan
One organic carbon and nitrogen measurement module
1 intelligent injection control module
One carbon isotope analysis module
1 set of consumables
1/100000 scale (optional)