KY-200ACrude oil organic chlorine content analyzerAccording to the principle of microcoulometry, various forms of total chlorine in the sample are converted into HCl at high temperatures in nitrogen and oxygen, and enter the titration cell. Through electrolysis, silver ions are produced in the cell and react with chloride ions. The microcomputer automatically calculates the total chlorine content in the sample based on the amount of electricity consumed by the silver ions produced and Faraday's law. The entire analysis process is controlled by a computer, and the samples are loaded by an automatic sampler, with a high degree of instrument automation. It can be used for the analysis of trace total chlorine in petrochemical products and is widely used in industries such as petroleum, chemical, scientific research, teaching, environmental protection, quality inspection, and commercial inspection.
KY-200ACrude oil organic chlorine content analyzerMain features of the instrument:
1.Introduce a digital coulomb analyzer with complete configuration and wide usage for total chlorine detection. A high-performance and highly automated total chlorine detector
2.Computer control, display of the entire process status, parameters, and printing of various results.
3.Simple operation, reliable performance, good stability, easy installation, the cracking system is air-cooled, and the fan automatically starts and stops.
KY-200AInstrument execution standard:
GB/T 18612-2011Standard for determination of organic chlorine content in crude oil
ASTM D5808-2009Test Method for Determination of Organic Chlorides in Aromatic Hydrocarbons and Related Compounds by Microelectricity Analysis
KY-200AMain technical parameters:
1.Sample types: liquid, solid, and gas (with corresponding injectors required)
2.Measurement method: Microcoulometric method
3.Measurement range: Total chlorine: 0.1mg/L~10000mg/L
4.Detection limit: Total chlorine: 0.1mg/L
5.Reproducibility error: Taking chlorine analysis as an example:
①X≤1.0mg/L <20%;
②1.0mg/L<X≤100mg/L <8%;
③X>100mg/L <3%.
6.Gas source requirements: ordinary oxygen, ordinary nitrogen
7.Temperature control range: room temperature~1100 ℃ 8. Temperature control accuracy: ± 1 ℃
9.Power: 1500W