KY-200Microcoulometric sulfur chlorine analyzerAccording to the principle of microcoulometry, various forms of sulfur (chlorine) in the sample are converted into sulfur dioxide (all converted into HCl) at high temperatures in nitrogen and oxygen. They enter the titration cell and react with iodine and sulfur dioxide through electrolysis (silver ions react with chloride ions through electrolysis in the cell). The microcomputer automatically calculates the total sulfur content (total chlorine content) in the sample based on the amount of electricity consumed by the iodine produced (the microcomputer calculates the amount of electricity consumed by the silver ions produced) and Faraday's law. The entire analysis process is controlled by a computer, and the samples are loaded by an automatic sampler, with a high degree of instrument automation. It can be used for the analysis of trace sulfur or chlorine in petrochemical products, and is widely used in industries such as petroleum, chemical, scientific research, teaching, environmental protection, quality inspection, and commercial inspection.Jiangsu Keyuan Electronic Instrument Co., Ltd. specializes in producing KY-200 microcomputer sulfur and chlorine analyzer, which is used for PetroChina, Sinopec, and CNOOC. KY-200 is your *!
Main features of the instrument:
vThe digital coulomb analyzer launched has the most comprehensive configuration and uses the most widely used sulfur (chlorine) analyzer. A high-performance and highly automated sulfur (chlorine) analyzer.
vComputer control, display of the entire process status, parameters, and printing of various results.
vSimple operation, reliable performance, good stability, easy installation, the cracking system is air-cooled, and the fan automatically starts and stops.
Instrument execution standard:
vSH/T 0253 Standard for Determination of Total Sulfur in Light Petroleum Products (Electricity Method)
vGB/T 11061.4 Determination of Total Sulfur in Natural Gas - Oxidative Microcoulometric Method Standard
vSH/T 0222 Standard for Determination of Total Sulfur Content in Liquefied Petroleum Gas (Electricity Method)
vGBT 18612 Determination Standard for Organic Chlorine Content in Crude Oil
Main technical parameters:
vSample types: liquid, solid, and gas (with corresponding injectors required)
vMeasurement method: Microcoulometric method
vMeasurement range: Sulfur: 0.1mg/L-10000mg/L Chlorine: 0.1mg/L-10000mg/L
Analysis after dilution when the concentration exceeds 5000mg/L
vDetection limit: 0.1mg/L (sulfur element) 0.1mg/L (chlorine element)
vReproducibility error: Taking sulfur analysis as an example
x<0.5mg/L,<30%
0.5mg/L≤x≤1.0mg/L, ±0.1mg/L
1.0mg/L ≤ X ≤ 10mg/L, Cv≤8%
X>10mg/L, Cv ≤ 3%
vTemperature control range: room temperature~1000℃
vGas source requirements: ordinary oxygen, ordinary nitrogen
Instrument system configuration:
vNormal configuration: KY-200 microcoulometric sulfur chlorine analyzer complete set (including computer, quartz tube, liquid sampler, etc.);
vOptional accessories: solid sampler, gas sampler, quartz tube cracking, and various standard samples.