E-mail
jykeyuan@126.com 、 13901422765@126.com
-
Phone
13901422765
-
Address
No. 998 Tianmu West Road, Jiangyan Economic Development Zone, Jiangsu Province
Jiangsu Keyuan Electronic Instrument Co., Ltd
jykeyuan@126.com 、 13901422765@126.com
13901422765
No. 998 Tianmu West Road, Jiangyan Economic Development Zone, Jiangsu Province
KY-200Microcoulometric chlorine analyzerAccording to the principle of microcoulometry, all forms of chlorine in the sample are converted into HCl at high temperatures in nitrogen and oxygen, and enter the titration cell. Iodine is produced through electrolysis, and silver ions react with chloride ions in the cell. The microcomputer automatically calculates the total chlorine content in the sample based on the amount of electricity consumed by the generated silver ions and Faraday's law. The entire analysis process is controlled by a computer, and the samples are loaded by an automatic sampler, with a high degree of instrument automation. It can be used for the analysis of trace sulfur or chlorine in petrochemical products, and is widely used in industries such as petroleum, chemical, scientific research, teaching, environmental protection, quality inspection, and commercial inspection.Jiangsu Keyuan Electronic Instrument Co., Ltd. specializes in producing KY-200 total chlorine analyzer, which is used for PetroChina, Sinopec, and CNOOC. KY-200 is your *!
Main features of the instrument:
vThe digital coulomb analyzer launched has the most comprehensive configuration and uses the most widely used chlorine analyzer. A chlorine analyzer with good performance and the highest degree of automation.
vComputer control, display of the entire process status, parameters, and printing of various results.
vSimple operation, reliable performance, good stability, easy installation, the cracking system is air-cooled, and the fan automatically starts and stops.
Instrument execution standard:
vGB/T 18612-2011 Determination of Organic Chlorine Content in Crude Oil
Main technical parameters:
vSample types: liquid, solid, and gas (with corresponding injectors required)
vMeasurement method: Microcoulometric method
vMeasurement range: Chlorine: 0.1mg/L~10000mg/LAnalysis after dilution when the concentration exceeds 5000mg/L
vDetection limit: 0.1mg/L (chlorine element)
vGas source requirements: ordinary oxygen, ordinary nitrogen
vTemperature control range: room temperature~1100℃
Instrument system configuration:
vNormal configuration: KY-200 microcoulometric chlorine analyzer complete set (including computer, quartz tube, liquid sampler, etc.);
vOptional accessories: solid sampler, gas sampler, quartz tube cracking, and various standard samples.