K9470ZK

NegotiableUpdate on 02/02
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
K9470ZK chromatograph accessories: GCRV-GBARS88N2373/A080/B036,GCRV-GBARS88N2373/A012/B036,GCRV-GBARS88N2373/A036/B036,GCRV-GBARS88N6181/A036/B036,GCRV-GBARS88N6181/A300/B036,GCRV-GBCRSCNN1500
Product Details

K9470ZK

Gas Chromatography AI Maintenance Support (GCAI) is the data monitoring software for the GC8000 process gas analyzer. The measurement data of GC8000 connected to the analyzer server software (PCAS) can be used to detect and visualize "abnormal" measurement conditions in real time. This system can help customers predict faults in advance for preventive maintenance planning and quickly solve immediate problems. It can also predict the future separation state of the measured peak to help optimize the column replacement time.

K9470ZKReal time monitoring and predictive detection of chromatography based on AI

Using GC8000 measurement data connected to the analyzer server software (PCAS), the machine learning model built in GCAI can detect "abnormal" measurement conditions as anomalies and visualize them in real-time.
Simply select the normal chromatographic data of GC8000 as a reference to easily construct the machine learning model. Due to the use of DuTe detection algorithm for each chromatogram in this model, it can adapt to various measurement specifications. Users can input and record the reasons for detected anomalies.
Historical abnormal frequencies can be analyzed based on their causes to assist in developing preventive maintenance plans.

K9470ZK

L9862AC/L9862AD

<
Replaced components>

L9862AG Filter unit

L9862AC gasket 1

L9862AD gasket 2

L9853AA needle valve

K9192WP Regulating valve for balancing atmospheric pressure (diaphragm:Viton

K9192WQ Regulating valve for balancing atmospheric pressure (diaphragm:Silicone

K9192GA Gas sampling (sealing gasket:Viton

K9193GB Liquid sampling (sealing gasket:Teflon

K9193GU Gas sampling (sealing gasket:Viton

L9866AK Cone shaped tube

L9866AP Cone shaped tube

L9866AR Cone shaped tube

L9866AS Cone shaped tube

K9193GQ gasket

K9193GR gasket

L9867AG 0~0.2MPa

L9867AJ 0~0.6MPa

K9193NX K9193NY K9193NZ

K9470ZK


  • Replace the base of the rotary valve

(1) Stop the system
(2) Turn off the sampling supply
(3) If the system is equipped with a flow path switching valve, set the operation mode to manual mode, and then prompt the sampling process to switch the system flow path
Replace the valve so that the left side of the valve opens.
(4) If the sampling is liquid, after turning off the sampling supply, blow the sampling pipeline with carrier gas and forced gas.
(5) Close the flow path switching valve.
(6) Turn off the power.

CAUTION
K9634DBThe thermostat is very hot when the power is just turned off. After turning off the power, continue to supply protective gas for one hour. Keep your hands away from the incubator
Components.

(7) Turn off the supply of protective gas, carrier gas, combustion hydrogen (or nitrogen) for FID, and combustion air.
(8) Manually loosen the nut and remove the pipeline.
(9) Remove the gasket, cover the assembly and valve base. Do not remove the washer and coil spring. (Refer to Figure 2.15)
(10) As shown in Figure 2.16, the orientation of the valve base and cover assembly is provided; These components should be positioned correctly during installation.
(11) When reassembling the components, follow the steps (8) to (9) in reverse and manually tighten the nuts. Do not use oil or grease
The grease sticks to the base.
K9634DB<Replaced Parts>
K9034ZA:CSW(Rulon) (K9034DN
K9034FF: Sampling volume: 0.33 μ l, material: Rolon
K9034DS: Sampling volume: 1 μ l, material: Rolon
K9034DR: Sampling volume: 2 μ l, material: Rolon
K9034DQ: Sampling volume: 3 μ l, material: Rolon
K9034DP: Sampling volume: 10 μ l or more, material: Rolon
K9034DN: Switching valve, material: Rolon
K9034DM: Plug
J9201HYSample size: 0.33 μ l, material: Teflon
K9034FLSample size: 1 μ l, material: Teflon
K9034FKSample size: 2 μ l, material: Teflon
K9034FJSample size: 3 μ l, material: Teflon
K9034FHSample size: 10 μ l or more, material: Teflon
*If you order them, you need P/N.
K9409ZE(2pcs of K9034DS)
K9409me(2pcs of K9034DR)
K9409ZC(2pcs of K9034DQ)
K9409ZB (2pcs of K9034DP)
K9409ZA(2pcs of K9034DN)

K9634DB

L9830AD、L9830AE、K9129WA、K9634WA、K9802AA

K9802DA、K9804DE、K9803VJ、L9862AG、K9192WL

K9192WP、K9800QM、L9830AC、L9830AD、L9830AE

K9409CA, K9802FA, K9193NU, K9193NX, K9630TU

GCRV-GBCRSCCN0711、GCRV-MBCRSCCN0711

GCRV-GBCRS8NN0100/A060、GCRV-GBARS8NN0100/A060

GCRV-GBARS88N2373/A080/B036、GCRV-GBARS88N2373/A080

GCRV-GBARS88N2373