Brief description: Intelligent radar level gauge price/Power plant silo radar level gauge/Top mounted radar level gauge is a microwave level gauge, which is an application of microwave (radar) positioning technology. It is transmitted through a device that can emit energy waves (usually pulse signals), which are reflected by obstacles and received by a receiving device. Suitable for measuring high temperature conditions such as blast furnace material level, thick tank tops, and high installation of short pipes, the high-temperature type can reach 350 ℃

Product Details

Intelligent radar level gauge price/power plant silo radar level gauge/top mounted radar level gauge

Intelligent radar level gauge price/power plant silo radar level gauge/top mounted radar level gaugeproduct overview

Intelligent radar level gauge is a microwave level gauge, which is an application of microwave (radar) positioning technology. It is transmitted through a device that can emit energy waves (usually pulse signals), which are reflected by obstacles and received by a receiving device. Determine the level change based on the time difference of the measured energy wave motion process. The microwave signal is processed by electronic devices and ultimately converted into an electrical signal related to the material level. In microwave level measurement equipment, the energy waves used are usually high-frequency electromagnetic waves. The energy wave used by this device is pulse energy wave. The maximum pulse energy of a typical pulse energy wave is around 1mW (with an average power of around 1 μ W), which will not cause radiation damage to other equipment or personnel.

Applicable scope and characteristics of radar level gauge

Intelligent radar level instruments are used for non-contact continuous measurement of the level of liquids, slurries, and particulate materials, and are suitable for situations with large temperature and pressure changes, as well as the presence of inert gases or vapors. It adopts the measurement method of microwave pulse (PTOF) and can operate normally in the industrial frequency band range. The beam energy is low and can be installed in various metal and non-metal containers or pipelines, without causing harm to the human body and the environment.

Has the following characteristics

1No blind spots, high precision

2Two wire technology is an excellent alternative product for differential pressure instruments, magnetostrictive instruments, radio frequency admittance instruments, and magnetic flap instruments.

3Not affected by environmental factors such as pressure changes, vacuum, temperature changes, inert gases, smoke, steam, etc

4Easy to install, sturdy and durable, maintenance free

5The output signal is 4mA~20mA or according to the HART protocol, with easy calibration and on-site calibration operation through digital LCD display. Simple configuration settings and programming are achieved through software

6Sensitive measurement and fast refresh rate.

7Suitable for high temperature conditions, with a process temperature of up to 200 ℃. When using a high-temperature extension antenna, it can reach up to 350 ℃

Main technical parameters of radar level gauge

1Measurement range: 0-45 meters;

2Process connection: thread or flange;

3Process temperature: -40-130 ℃ (high temperature type can reach 350 ℃);

4Process pressure: -1.0... 60 bar;

5Operating frequency: 8.4GHz;

6Beam angle: around 20 °;

7Repeatability: ± 3mm;

8Resolution: 1mm;

9Current signal: 4-20mA/HART communication protocol;

10Accuracy:<0.1%;

11Communication interface: HART communication protocol;

12Power supply: 24V DC (+/-10%)/Ripple voltage: 1Vpp;

13Power consumption: 22.5mA (max);

14Response time: ≥ 0.3s (depending on specific circumstances);

15Explosion proof certification: Exia II CT6;

16Shell protection level: IP68;

17Two wire wiring: power supply and signal output share one two core wire;

18Cable entrance: Two M20 x 1.5 (cable diameter 5... 9mm).

Radar level gauge model and specifications

SF-LD603

code

A1

Stick/PP

Antenna type and material

A2

Rod/PTFE (regular type)

A3

Rod/PTFE (anti-corrosion type)

A4

Rod/PTFE (high temperature type)

B1

Horn type Φ 75mm/316 L

B2

Horn type Φ 95mm/316 L

B3

Horn type Φ 146mm/316 L

B4

Horn type Φ 190mm/316 L

B5

Horn type Φ 240mm/316 L

0

Not extended

Antenna extension tube

1

100

2

200

3

250

4

300

5

other

A

threaded

Process connection

B

Standard flange

P

Common

Explosion proof options

I

Intrinsically safe type

1

-20~130℃

process temperature

2

-40~130℃

3

-40~220℃

4

-30~350℃

5

other

1

local display

Display and Programmer

2

The programmer

3

On site display+programmer

4

not have

X

Customer requirements: such as explosion-proof casing, etc

Other options