Industrial liquid online density meter
Product Description:
MD-The 3051 series intelligent online density meter can measure the density of various liquids or liquid mixtures online. It can be widely used in the petrochemical industry for petroleum, refining, oil blending, and oil-water interface detection; Used in the food industry for production sites such as grape juice, tomato juice, fruit syrup, vegetable oil, and soft drink processing; Dairy industry; Paper industry; Testing of black, green, white, and alkaline solutions; Alcohol content in brewing; Testing of urea, cleaning agents, ethylene glycol, acidity and alkalinity, and polymer density in the chemical industry. It can also be applied to industries such as mining mud, saltwater, potash, natural gas, lubricants, biopharmaceuticals, etc.
Main features of intelligent online liquid density meter: 1. Adopting an integrated structure of two-wire transmitter, with no moving parts and simple maintenance.2. Four and a half digit LCD display.3. Easy to install and use, simply insert liquid to display readings.4. Used for fluids or stationary liquids, suitable for pipeline and tank installation.5. The two parameters of temperature and density can be displayed alternately, making it convenient for industry standard density conversion.6. Continuous online measurement of liquid density without process interruption, can be directly used for production process control.7. All parts in contact with liquids are made of several types of medium stainless steel materials, ensuring safety; hygiene.8. This safety type can be used in hazardous environments; Sanitary type can be installed on food production sites
Technical indicators of intelligent online density meter
14~20mAcurrent output.Select and add digital signal(HARTAgreement)
216~30VDCpower supply.Recommended use24VDC.
3. Density range0~2can/Cubic centimeter;0~3can/cubic centimeter
4. Accuracy0.001can/cubic centimeter
5. Resolution0.0005can/cubic centimeter
6. Temperature range0~100℃
7. Temperature accuracy0.2℃
8. Environmental temperature-10~60℃
9. Humidity range0-90%
Ordering precautions
1. The density meter diaphragm is the weakest part. Please do not let sharp objects impact the diaphragm and cause damage.
2MD3051In theory, online density meters can measure concentrations based on different media. Please use the method to convert the concentration results according to the on-site situation.
3. When selecting, please ask the manufacturer and provide on-site installation information, and indicate it when signing the contract.
4. If calibration or adjustment is required, please contact the manufacturer.
Selection instructions:
| model | Specification code | describe |
| SF-MD3051 | ··············· | Industrial online density meter |
| Installation and appearance | A··············· | Direct installation type |
| B··············· | Elbow type | |
| C··············· | Side mounted | |
| Membrane box (sensor) | 5··············· | 500mmthe above |
| 10··············· | 1000mm | |
| 15··············· | special requirements | |
| Distance between flange sensors | M··············· | 300mm |
| F··············· | User defined distance | |
| measuring range | 1··············· | 0~1 can/cubic centimeter |
| 2··············· | 0~2 can/cubic centimeter | |
| 3··············· | 0~3 can/cubic centimeter | |
| mounting flange | H6··············· | DN65 |
| H8··············· | DN80 | |
| H10··············· | DN100 | |
| Typical example of flange installation: MD3051A5M1H8 | ||
| The following is the default configuration: | ||
| Display header | ··············· | LCD intelligent display table |
| output signal | ··············· | 4~20mA |
| Input power supply | ··············· | 24VDC |
| Membrane structure material | ··············· | 316 stainless steel (other available for order) |
| Transport packaging | ··············· | WOODEN CASE |
Three:Installation matters
1:direct-type The minimum distance between the sensors of the online liquid density meter is200mm,The diameter is50mm,Installation on site cannot be smaller than these dimensions,If choosing a curved densitometer,Please measure the flange and length dimensions that can be inserted into the pipe.
2: The on-site liquid must be kept below two measuring sensors,The distance from the flange to * sensors is optional.
3: During pipeline installation, it is necessary to allow the liquid to enter from below the sensor at Zui, or from above the sensor at Zui. Do not enter the liquid from the middle. When installing pipelines for liquid flow, at least leave enough space for the valve or elbow section of the pipeline30CMLiquid buffer distance.
4: Installation diagram: red flange matching part,Provide installation for users,If matching flanges is required,Please specify when placing an order.
5: Equipped with a power supply24V DCoutput4-20mAIf the signal needs to be connected to a secondary meter, it is necessary to24V“+”
Received from behind the densitometer“+”Pole, current signal“+”Connect density meter“-”Extreme, and on the secondary table24V“-”And current signal terminal“-”Short circuit.
6: If there are corrosive liquids outside the site environment, please take protective measures. If there is a risk of lightning strikes, please install grounding devices in the surrounding area.
7: When disassembling for cleaning, please ensure that the sensor diaphragm is not damaged by collision or other factors.
8: Please do not go above5MpUse under situation a.
9: If you need to adjust the range, you need to use a handheld device,Please ask the manufacturer for technical issues.