Welcome Customer !

Membership

Help

Shanghai Prima Electronics Co., Ltd
Custom manufacturer

Main Products:

intelligent-mfg>Products

Industrial anti-interference generator

NegotiableUpdate on 01/29
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Industrial anti-interference generator, including three testing functions: electrostatic discharge discharge, electrical fast transient pulse group, and lightning surge; The product complies with standards such as IEC61000-2/4/5 and GB/T17626.2/4.5.
Product Details

Industrial anti-interference generatorFeatures:
1. The combination of electrostatic discharge, transient pulse, and lightning surge is unique in China;
2. Static high output voltage ± 20KV, group pulse high output frequency up to 1200KHz, lightning strike up to 6KV;
3. The modular design of electrostatic discharge, transient pulse, and lightning surge functions is independent and does not interfere with each other;
4. 7.0-inch touch screen, Chinese English display, easy to operate;
5. Ergonomic design of electrostatic gun, gun body weight less than 1kg, comfortable to use;
6. Introduction of Swiss technology for electrostatic high-voltage discharge module, with automatic positive and negative switching;
7. Modular design of electrostatic resistance and capacitance kit, easy to replace, meets testing requirements of different standards;
8. Real time static indicator light display to determine the failure of air discharge;
9. The pulse and surge modules use electronic switches imported from Germany, with smooth and accurate waveforms;
10. Pulse and surge built-in intelligent coupling/decoupling network, intelligent switching of coupling modes, and safe experiments;
11. The surge test mode automatically switches to all gears without the need for manual operation;
12. Asynchronous or 0-360 ° free setting of surge injection phase angle;
13. The control module adopts imported programmable high-voltage power supply, with stable performance;
14. Built in software protection, no need to pay attention to the operation sequence;
15. Built in temperature and humidity display, real-time voltage display, real-time judgment of experimental reliability;
16. Built in national standard mode, user-defined mode, and boost mode;
17. Built in RS232 interface, optional measurement and control software for remote control.

Maintenance;

1. Replace the hydraulic oil and clean the oil tank every six months, using the recommended model of oil;

2. Regularly check whether the cooling device starts automatically when the weather is hot (when the oil temperature is ≥ 45 degrees). (The cooling water temperature must be below 30 degrees)

3. Clean the air filter while cleaning the fuel tank;

4. Regularly check the oil filter signal light of the DC high-voltage generator. As soon as the signal light is on (and the buzzer sounds), immediately clean the oil filter;

5. According to regulations, it is necessary to lubricate each lubrication point of the mechanical transmission part of the equipment;

6. Regularly observe the condition of the liquid, and if the liquid level approaches, please replenish the recommended hydraulic oil in the oil tank in a timely manner;

7. Regularly check the dust prevention devices at all locations. If any damage or loose connections are found, they should be dealt with in a timely manner to prevent sand and dust from entering and damaging the equipment

Industrial anti-interference generatorparameter


electricity
put
electricity

output voltage

0.2~ ± 20 kV

Discharge form

Contact discharge/air discharge (holding time ≥ 5s)

work format

The discharge time interval can be set between 0.05 and 99.99 seconds, and can be set to various operation modes such as single discharge and 20PPS discharge

Discharge capacitor/resistor

150pF/330 Ω (interchangeable with various resistance and capacitance kits)

Rise time of discharge current

0.6 ~ 1ns

electricity

quick

quick

instant

change

pulse

charge

group

output voltage

0.2 to ± 4.8KV positive or negative, alternating positive and negative

pulse frequency

1kHz~1200kHz ± 10%, continuously adjustable

internal resistance

50 Ω±20%

Pulse front

5ns ± 30%

pulse width

Load characteristic impedance 50 Ω

Load characteristic impedance 1k Ω

50ns ± 30%

35 ns~150 ns

Pulse train length

1-255 adjustable

Pulse train period

Typical 300mS (adjustable from 0.15-99.99S, with an adjustment accuracy of 0.01S)

EUT coupling/decoupling network

Built in intelligent single-phase three wire power supply network (load current 16A)

thunder

hit

wave

surge

Open circuit output voltage/current

Integrated wave 1.2/50 μ s, 0.2-6kV

Current wave 8/20 μ s, 0.1-3kA

Surge polarity

Positive/negative, alternating positive and negative

phase

When synchronized with the power supply, it is 0 °~360 ° or asynchronous

output impedance

Combination wave 2 Ω

Coupling/decoupling network

Built in intelligent single-phase three wire power supply network (load current 16A)

frequency

1~9999 times

interval

10~9999S

working power supply

AC220V 50/60Hz

Overall dimensions

465 * 565 * 525mm Weight 32KG