E-mail
1987440091@qq.com
-
Phone
19901806598
-
Address
No. 77 Shenglong Road, Jiufu Development Zone, Songjiang District, Shanghai
Shanghai Prima Electronics Co., Ltd
1987440091@qq.com
19901806598
No. 77 Shenglong Road, Jiufu Development Zone, Songjiang District, Shanghai
Industrial anti-interference generatorFeatures:
1. The combination of electrostatic discharge, transient pulse, and lightning surge is unique in China;
2. Static high output voltage ± 20KV, group pulse high output frequency up to 1200KHz, lightning strike up to 6KV;
3. The modular design of electrostatic discharge, transient pulse, and lightning surge functions is independent and does not interfere with each other;
4. 7.0-inch touch screen, Chinese English display, easy to operate;
5. Ergonomic design of electrostatic gun, gun body weight less than 1kg, comfortable to use;
6. Introduction of Swiss technology for electrostatic high-voltage discharge module, with automatic positive and negative switching;
7. Modular design of electrostatic resistance and capacitance kit, easy to replace, meets testing requirements of different standards;
8. Real time static indicator light display to determine the failure of air discharge;
9. The pulse and surge modules use electronic switches imported from Germany, with smooth and accurate waveforms;
10. Pulse and surge built-in intelligent coupling/decoupling network, intelligent switching of coupling modes, and safe experiments;
11. The surge test mode automatically switches to all gears without the need for manual operation;
12. Asynchronous or 0-360 ° free setting of surge injection phase angle;
13. The control module adopts imported programmable high-voltage power supply, with stable performance;
14. Built in software protection, no need to pay attention to the operation sequence;
15. Built in temperature and humidity display, real-time voltage display, real-time judgment of experimental reliability;
16. Built in national standard mode, user-defined mode, and boost mode;
17. Built in RS232 interface, optional measurement and control software for remote control.
Maintenance;
1. Replace the hydraulic oil and clean the oil tank every six months, using the recommended model of oil;
2. Regularly check whether the cooling device starts automatically when the weather is hot (when the oil temperature is ≥ 45 degrees). (The cooling water temperature must be below 30 degrees)
3. Clean the air filter while cleaning the fuel tank;
4. Regularly check the oil filter signal light of the DC high-voltage generator. As soon as the signal light is on (and the buzzer sounds), immediately clean the oil filter;
5. According to regulations, it is necessary to lubricate each lubrication point of the mechanical transmission part of the equipment;
6. Regularly observe the condition of the liquid, and if the liquid level approaches, please replenish the recommended hydraulic oil in the oil tank in a timely manner;
7. Regularly check the dust prevention devices at all locations. If any damage or loose connections are found, they should be dealt with in a timely manner to prevent sand and dust from entering and damaging the equipment
Industrial anti-interference generatorparameter
|
| output voltage | 0.2~ ± 20 kV | |
| Discharge form | Contact discharge/air discharge (holding time ≥ 5s) | ||
| work format | The discharge time interval can be set between 0.05 and 99.99 seconds, and can be set to various operation modes such as single discharge and 20PPS discharge | ||
| Discharge capacitor/resistor | 150pF/330 Ω (interchangeable with various resistance and capacitance kits) | ||
| Rise time of discharge current | 0.6 ~ 1ns | ||
| electricity quick quick instant change pulse charge group | output voltage | 0.2 to ± 4.8KV positive or negative, alternating positive and negative | |
| pulse frequency | 1kHz~1200kHz ± 10%, continuously adjustable | ||
| internal resistance | 50 Ω±20% | ||
| Pulse front | 5ns ± 30% | ||
| pulse width | Load characteristic impedance 50 Ω Load characteristic impedance 1k Ω | 50ns ± 30% 35 ns~150 ns | |
| Pulse train length | 1-255 adjustable | ||
| Pulse train period | Typical 300mS (adjustable from 0.15-99.99S, with an adjustment accuracy of 0.01S) | ||
| EUT coupling/decoupling network | Built in intelligent single-phase three wire power supply network (load current 16A) | ||
| thunder hit wave surge | Open circuit output voltage/current | Integrated wave 1.2/50 μ s, 0.2-6kV Current wave 8/20 μ s, 0.1-3kA | |
| Surge polarity | Positive/negative, alternating positive and negative | ||
| phase | When synchronized with the power supply, it is 0 °~360 ° or asynchronous | ||
| output impedance | Combination wave 2 Ω | ||
| Coupling/decoupling network | Built in intelligent single-phase three wire power supply network (load current 16A) | ||
| frequency | 1~9999 times | ||
| interval | 10~9999S | ||
| working power supply | AC220V 50/60Hz | ||
| Overall dimensions | 465 * 565 * 525mm Weight 32KG | ||