High current injection (BCI) testing system

NegotiableUpdate on 01/29
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The PBCI-100PB/C high current injection (BCI) testing system is an integrated conductivity sensitivity testing system according to the ISO11452-4 standard, which meets a series of standard requirements such as GB/T17626.6/ISO11452-4/National Military Standard GJB151B CS114. Built in signal source, power amplifier, and power meter.
Product Details

High current injection(BCI)Testing System

Product Model

PBCI-100PB

PBCI-100PC

meet the standard

ISO11452-4

GJB151B CS114

frequency range

100kHz400MHz

4kHz400MHz

Inject current

40-300mA (clamp injection)

Step by step method

Linear stepping (0.1-100MHz adjustable)

Proportional step (0.2-10%)

output power

100W

current range

40mA300mA

dwell time

Can be set from 0.5s to 60s

harmonic

≤-30 dBc/<15dBc

output interface

N-type (female)

Power-on preheating

20 minutes

signal source(Built in)

Output frequency

4k-3GHz

output power

-120dBm10dBm

Non modulated signal

Equal amplitude continuous wave

modulation mode

amplitude modulation

frequency1Hz100kHz

Depth:1100%

Pulse Modulation

frequency1Hz100kHz

Duty cycle:1100%

output interface

N (mother)

Power amplifier (built-in)

output frequency

100kHz400MHz

4kHz400MHz

Maximum output power

+44dBm/100W

Voltage Standing Wave Ratio

1.5

gain

maximum gain50dB/100W

VSWR

<1.5:1

output impedance

50Ω

output interface

N (mother)

Power meter (built-in)

test level

-70dBm+15dBm

frequency range

4kHz400MHz

Voltage Standing Wave Ratio

1.1

precision

±0.3dB

input interface

BNC(Mother)

Current injection clamp (with calibration component)PRM-ICC-40D

frequency range

4kHz500MHz

Maximum input power

100W(Long term use)150W15Minutes)200W5Minutes)

Overall dimensions

outer diameter127mminner diameter40mmthickness80mm

Attenuator (injection clamp calibration component)

output impedance

50Ω

output power

100W

output frequency

DC-3GHz

Attenuation value and accuracy

3dBor6dB(±0.4

Maximum standing wave ratio

1.1

load(Injection clamp calibration part)

output impedance

50Ω

output power

100W

output frequency

DC-3GHz

Current monitoring probePRM-CL-52M

frequency range

1KHz500MHz

transfer impedanceZT(Ω)

0.1

transfer impedanceZTdBΩ)

1

Insert impedance

1Ω

Maximum bias current

150A(DC-400Hz)

Maximum measured RF current

2A

Overall dimensions

outer diameter98mminner diameter40mmthickness38mm

satisfyCS114Artificial power networkLISN-50-2550doDCTest configuration2a

frequency range

0.1-110MHzUpgradeable to150MHz

Network load capacity

DC250V/50A

impedance

50Ω

size

185*180*390mm

satisfyISO11452-4Artificial power network parametersLISN-5-5080doDCTest configuration2a

frequency range

0.1-110MHzUpgradeable to150MHz

Network load capacity

DC500V/80A

impedance

50Ω

size

162*172*222mm

test environmentBCI-DESK

Test table (solid wood)

2400*1000*800mm

Test reference plane (copper)

2400*1000*2mm

General Parameters

Instrument working status indication

front panelPCIndustrial control computer operation display

system

WIN system,canRandom storage test report

interface

USB

Equipment working power supply

AC220V ± 10%,50/60Hz (Chinese Mainland only)

fuse

3A

Maximum Power Consumption

200W

ambient temperature

15 ℃ -35 ℃

Pressure range

86KPa-106kpa

grounding resistance

Less than 0.5 Ω

host size

5U 450×550×222mm

weight

10kg