Phone
15965947666
-
Address
Tengzhuang Development Zone, Wucheng, Dezhou
Shandong Tengxiang Group Silencing Ventilation and Air Conditioning Equipment Factory
15965947666
Tengzhuang Development Zone, Wucheng, Dezhou
Detailed introduction of fire smoke exhaust fan
Detailed explanation of outstanding performance of fire smoke exhaust fan
The fire exhaust fan has ultra-high performance. Next, we will show you in detail:
1. Excellent high temperature resistance: The fire smoke exhaust fan test meets the requirements of GA211-1999 (Fire Smoke Exhaust High Temperature Resistance Test Method) standard, establishing an internal guarantee system higher than this standard, and can operate continuously for 100 minutes under high temperature conditions of 400 ℃; Continuous operation for 20 hours/time at a temperature of 100 ℃ without damage, widely used in high-end civil buildings, ovens, underground garages, tunnels and other occasions.
2. The fire smoke exhaust fan has advanced technology and stable performance. It has passed the inspection of the National Fire Equipment Quality Supervision and Inspection Center, and its performance has reached the leading level in China.
3. High efficiency: This fan adopts advanced CAD system software and is a new product developed through multi-objective optimization design. The fan efficiency is greater than 80% and has a flat efficiency curve, which is conducive to energy conservation.
4. The fire exhaust fan has a wide range of applications: it can be driven by variable speed or multi speed according to the different requirements of high-end civil buildings, in order to achieve the purpose of one machine for two uses (i.e. normal exhaust and high-temperature smoke exhaust during fire protection).
5. Easy installation: occupies less space than centrifugal fans; The basic form of this fan is an axial flow fan, which can be directly installed with the wall. The installation form can be vertical, horizontal or suspended, which greatly saves the floor space. At the same time, it is not affected by the large machine number and the required large air volume. It adopts a motor direct connection type, making its operation reliable.
The outstanding performance of the fire smoke exhaust fan mainly lies in these aspects. We must operate it reasonably according to the instructions to fully demonstrate its performance. If you have any further questions, please feel free to consult us in a timely manner.
Performance Parameters Table of XGF-I High Temperature Smoke Exhaust Fan for Firefighting
| model |
Diameter of airflow inlet and outlet
(mm)
|
Air volume
(m³/h)
|
Total pressure
(Pa)
|
rotational speed
(rpm)
|
installed capacity
(kw)
|
A-level sound
dB(A)
|
weight
(kg)
|
| 3.5 | 350 |
4225
3840
3350
|
280
360
420
|
2900 | 0.75 | ≤78 | 77 |
| 4 | 400 |
5500
4800
3800
|
300
380
450
|
2900 | 1.5 | ≤79 | 88 |
| 4.5 | 450 |
8500
7800
6120
|
410
550
670
|
2900 | 2.2 | ≤84 | 99 |
| 5 | 500 |
9824
8861
6817
|
510
610
752
|
2900 | 3 | ≤86 | 110 |
| 5.5 | 550 |
15200
12000
10900
|
398
592
621
|
2900 | 4 | ≤86 | 115 |
| 6 | 600 |
16090
15102
13197
|
510
610
760
|
2900 | 5.5 | ≤86 | 164 |
| 6.3 | 630 |
20210
18700
15600
|
480
510
580
|
1450 | 5.5 | ≤87 | 165 |
| 6.5 | 650 |
21500
18000
15300
|
425
620
680
|
1450 | 5.5 | ≤88 | 170 |
| 7 | 700 |
24380
22439
18908
|
610
655
728
|
1450 | 7.5 | ≤88 | 208 |
| 8 | 800 |
31421
29172
26012
|
600
661
723
|
1450 | 7.5 | ≤89 | 216 |
| 9 | 900 |
33510
32297
27613
|
562
668
840
|
1450 | 11 | ≤90 | 250 |
| 10 | 1000 |
45679
40000
35000
|
630
690
770
|
1450 | 11 | ≤90 | 300 |
| 11 | 1100 |
51552
50128
48500
|
580
647
690
|
1450 | 15 | ≤92 | 380 |
| 12 | 1200 |
62763
59300
57748
|
624
680
740
|
960 | 18.5 | ≤93 | 480 |
| 13 | 1300 |
74708
65370
56031
|
600
710
807
|
960 | 18.5 | ≤94 | 520 |
| 15 | 1500 |
93800
86115
76041
|
623
710
819
|
960 | 22 | ≤95 | 650 |
Performance Parameters Table of XGF-I High Temperature Smoke Exhaust Fan for Firefighting
| model | Diameter of airflow inlet and outlet (mm) |
Air volume
(m³/h)
|
Total pressure
(Pa)
|
rotational speed
(rpm)
|
installed capacity
(kw)
|
Actual power consumption
(kw)
|
A-level sound
dB(A)
|
weight
(kg)
|
| 5 | 500 |
9824
8861
6817
|
510
610
752
|
2900 | 3/2.5 | 2.5/0.3 | ≤86 | 110 |
|
4912
4431
3410
|
127
153
188
|
1450 | ≤75 | |||||
| 5.5 | 550 |
15200
12000
10900
|
398
592
621
|
2900 | 4/3.3 | 3.0/0.39 | ≤86 | 115 |
|
7600
6000
5450
|
100
148
155
|
1450 | ≤75 | |||||
| 6 | 600 |
16090
15102
13197
|
510
610
760
|
2900 | 5.5/4.5 | 4.7/0.6 | ≤86 | 164 |
|
8045
7551
6599
|
127
153
190
|
1450 | ≤75 | |||||
| 6.5 | 650 |
21500
18000
15300
|
425
620
680
|
1450 | 5.5/4 | 5.1/1.5 | ≤88 | 170 |
|
14235
11918
10130
|
187
272
298
|
960 | ≤80 | |||||
| 7 | 700 |
24380
22439
18908
|
610
655
728
|
1450 | 8/6.5 | 7/2 | ≤88 | 218 |
|
16141
14865
12518
|
267
287
319
|
960 | ≤80 | |||||
| 8 | 800 |
31421
29172
26012
|
600
661
723
|
1450 | 8/6.5 | 7.1/4.1 | ≤89 | 226 |
|
20800
19314
17222
|
263
290
317
|
960 | ≤80 | |||||
| 9 | 900 |
33510
32297
27513
|
562
558
840
|
1450 | 11/9 | 10.4/6.8 | ≤90 | 250 |
|
22186
21383
18216
|
246
293
368
|
960 | ≤81 | |||||
| 10 | 1000 |
45679
40000
35000
|
630
690
770
|
1450 | 11/9 | 10.5/6.9 | ≤90 | 305 |
|
30255
26483
24019
|
276
302
338
|
960 | ≤80 | |||||
| 11 | 1100 |
51552
50128
48500
|
580
647
690
|
1450 | 16/13 | 14.5/6.1 | ≤92 | 390 |
|
38664
37596
36375
|
326
364
387
|
960 | ≤83 | |||||
| 12 | 1200 |
62763
59300
55651
|
624
680
740
|
960 | 17/8 | 15/6.3 | ≤93 | 485 |
|
47072
44475
43311
|
351
383
416
|
720 | ≤83.5 | |||||
| 13 | 1300 |
74708
65370
56031
|
600
710
807
|
960 | 17/8 | 15/6.3 | ≤94 | 525 |
|
56031
49027
42023
|
338
399
454
|
720 | ≤84.5 | |||||
| 15 | 1500 |
93800
86115
76041
|
623
710
819
|
960 | 22/11 | 20/8.5 | ≤95 | 655 |
|
70350
64586
57031
|
350
410
461
|
720 | ≤85 |
XGF-I Type Fire High Temperature Smoke Exhaust Special Fan Outline Dimensional Table
| model | D1 | D2 | M1 | M2 | M3 | M4 | L | H | n-φ1 | φ2 |
| 3.5 | 425 | 395 | 340 | 380 | 200 | 240 | 560 | 232 | 8-φ9 | φ11 |
| 4 | 480 | 454 | 380 | 420 | 200 | 300 | 560 | 258 | 8-φ9 | φ11 |
| 4.5 | 540 | 500 | 380 | 420 | 300 | 400 | 600 | 290 | 8-φ9 | φ11 |
| 5 | 592 | 552 | 450 | 490 | 300 | 400 | 650 | 316 | 8-φ11 | φ11 |
| 5.5 | 644 | 600 | 470 | 510 | 400 | 500 | 680 | 352 | 10-φ11 | φ15 |
| 6 | 692 | 652 | 490 | 530 | 400 | 500 | 700 | 378 | 10-φ11 | φ15 |
| 6.3 | 734 | 685 | 490 | 530 | 400 | 500 | 800 | 395 | 10-φ11 | φ15 |
| 6.5 | 754 | 700 | 560 | 600 | 500 | 600 | 800 | 402 | 10-φ11 | φ15 |
| 7 | 793 | 753 | 580 | 620 | 500 | 600 | 830 | 428 | 10-φ11 | φ15 |
| 8 | 893 | 853 | 580 | 620 | 500 | 600 | 790 | 487 | 12-φ11 | φ15 |
| 9 | 994 | 954 | 600 | 660 | 600 | 700 | 860 | 538 | 12-φ11 | φ19 |
| 10 | 1096 | 1056 | 630 | 690 | 600 | 700 | 900 | 600 | 12-φ11 | φ19 |
| 11 | 1218 | 1168 | 740 | 810 | 730 | 790 | 1060 | 650 | 14-φ13 | φ19 |
| 12 | 1322 | 1272 | 840 | 910 | 870 | 930 | 1200 | 700 | 14-φ13 | φ19 |
| 13 | 1422 | 1372 | 840 | 910 | 920 | 980 | 1200 | 750 | 16-φ13 | φ21 |
| 15 | 1622 | 1572 | 840 | 910 | 1000 | 1100 | 1200 | 850 | 18-φ15 | φ21 |
XGF-II Fire High Temperature Smoke Exhaust Special Fan Outline Dimensional Table
| model | D1 | D2 | M1 | M2 | M3 | M4 | L | H | n-φ1 | φ2 |
| 5 | 592 | 552 | 450 | 490 | 300 | 400 | 650 | 316 | 8-φ11 | φ11 |
| 5.5 | 644 | 600 | 470 | 510 | 400 | 500 | 680 | 352 | 10-φ11 | φ15 |
| 6 | 692 | 652 | 490 | 530 | 400 | 500 | 700 | 378 | 10-φ11 | φ15 |
| 6.5 | 754 | 700 | 560 | 650 | 500 | 600 | 800 | 402 | 10-φ11 | φ15 |
| 7 | 793 | 753 | 610 | 670 | 500 | 600 | 870 | 428 | 10-φ11 | φ15 |
| 8 | 893 | 853 | 610 | 670 | 500 | 600 | 870 | 487 | 12-φ11 | φ15 |
| 9 | 994 | 954 | 650 | 710 | 600 | 700 | 900 | 538 | 12-φ11 | φ19 |
| 10 | 1096 | 1056 | 660 | 720 | 600 | 700 | 950 | 600 | 12-φ11 | φ19 |
| 11 | 1218 | 1168 | 810 | 880 | 730 | 790 | 1160 | 650 | 14-φ13 | φ19 |
| 12 | 1322 | 1272 | 840 | 910 | 870 | 930 | 1200 | 700 | 14-φ13 | φ19 |
| 13 | 1422 | 1372 | 840 | 910 | 920 | 980 | 1200 | 750 | 16-φ13 | φ21 |
| 15 | 1622 | 1572 | 880 | 950 | 1000 | 1100 | 1200 | 850 | 18-φ15 | φ21 |