Welcome Customer !

Membership

Help

Shandong Tengxiang Group Silencing Ventilation and Air Conditioning Equipment Factory
Custom manufacturer

Main Products:

intelligent-mfg>Products

Shandong Tengxiang Group Silencing Ventilation and Air Conditioning Equipment Factory

  • E-mail

  • Phone

    15965947666

  • Address

    Tengzhuang Development Zone, Wucheng, Dezhou

Contact Now

Fire exhaust fan

NegotiableUpdate on 05/01
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Fire exhaust fan

Product Details

Detailed introduction of fire smoke exhaust fan

Detailed explanation of outstanding performance of fire smoke exhaust fan

The fire exhaust fan has ultra-high performance. Next, we will show you in detail:

1. Excellent high temperature resistance: The fire smoke exhaust fan test meets the requirements of GA211-1999 (Fire Smoke Exhaust High Temperature Resistance Test Method) standard, establishing an internal guarantee system higher than this standard, and can operate continuously for 100 minutes under high temperature conditions of 400 ℃; Continuous operation for 20 hours/time at a temperature of 100 ℃ without damage, widely used in high-end civil buildings, ovens, underground garages, tunnels and other occasions.

2. The fire smoke exhaust fan has advanced technology and stable performance. It has passed the inspection of the National Fire Equipment Quality Supervision and Inspection Center, and its performance has reached the leading level in China.

3. High efficiency: This fan adopts advanced CAD system software and is a new product developed through multi-objective optimization design. The fan efficiency is greater than 80% and has a flat efficiency curve, which is conducive to energy conservation.

4. The fire exhaust fan has a wide range of applications: it can be driven by variable speed or multi speed according to the different requirements of high-end civil buildings, in order to achieve the purpose of one machine for two uses (i.e. normal exhaust and high-temperature smoke exhaust during fire protection).

5. Easy installation: occupies less space than centrifugal fans; The basic form of this fan is an axial flow fan, which can be directly installed with the wall. The installation form can be vertical, horizontal or suspended, which greatly saves the floor space. At the same time, it is not affected by the large machine number and the required large air volume. It adopts a motor direct connection type, making its operation reliable.

The outstanding performance of the fire smoke exhaust fan mainly lies in these aspects. We must operate it reasonably according to the instructions to fully demonstrate its performance. If you have any further questions, please feel free to consult us in a timely manner.

Performance Parameters Table of XGF-I High Temperature Smoke Exhaust Fan for Firefighting

model
Diameter of airflow inlet and outlet
(mm)
Air volume
(m³/h)
Total pressure
(Pa)
rotational speed
(rpm)
installed capacity
(kw)
A-level sound
dB(A)
weight
(kg)
3.5 350
4225
3840
3350
280
360
420
2900 0.75 ≤78 77
4 400
5500
4800
3800
300
380
450
2900 1.5 ≤79 88
4.5 450
8500
7800
6120
410
550
670
2900 2.2 ≤84 99
5 500
9824
8861
6817
510
610
752
2900 3 ≤86 110
5.5 550
15200
12000
10900
398
592
621
2900 4 ≤86 115
6 600
16090
15102
13197
510
610
760
2900 5.5 ≤86 164
6.3 630
20210
18700
15600
480
510
580
1450 5.5 ≤87 165
6.5 650
21500
18000
15300
425
620
680
1450 5.5 ≤88 170
7 700
24380
22439
18908
610
655
728
1450 7.5 ≤88 208
8 800
31421
29172
26012
600
661
723
1450 7.5 ≤89 216
9 900
33510
32297
27613
562
668
840
1450 11 ≤90 250
10 1000
45679
40000
35000
630
690
770
1450 11 ≤90 300
11 1100
51552
50128
48500
580
647
690
1450 15 ≤92 380
12 1200
62763
59300
57748
624
680
740
960 18.5 ≤93 480
13 1300
74708
65370
56031
600
710
807
960 18.5 ≤94 520
15 1500
93800
86115
76041
623
710
819
960 22 ≤95 650

Performance Parameters Table of XGF-I High Temperature Smoke Exhaust Fan for Firefighting

model Diameter of airflow inlet and outlet (mm)
Air volume
(m³/h)
Total pressure
(Pa)
rotational speed
(rpm)
installed capacity
(kw)
Actual power consumption
(kw)
A-level sound
dB(A)
weight
(kg)
5 500
9824
8861
6817
510
610
752
2900 3/2.5 2.5/0.3 ≤86 110
4912
4431
3410
127
153
188
1450 ≤75
5.5 550
15200
12000
10900
398
592
621
2900 4/3.3 3.0/0.39 ≤86 115
7600
6000
5450
100
148
155
1450 ≤75
6 600
16090
15102
13197
510
610
760
2900 5.5/4.5 4.7/0.6 ≤86 164
8045
7551
6599
127
153
190
1450 ≤75
6.5 650
21500
18000
15300
425
620
680
1450 5.5/4 5.1/1.5 ≤88 170
14235
11918
10130
187
272
298
960 ≤80
7 700
24380
22439
18908
610
655
728
1450 8/6.5 7/2 ≤88 218
16141
14865
12518
267
287
319
960 ≤80
8 800
31421
29172
26012
600
661
723
1450 8/6.5 7.1/4.1 ≤89 226
20800
19314
17222
263
290
317
960 ≤80
9 900
33510
32297
27513
562
558
840
1450 11/9 10.4/6.8 ≤90 250
22186
21383
18216
246
293
368
960 ≤81
10 1000
45679
40000
35000
630
690
770
1450 11/9 10.5/6.9 ≤90 305
30255
26483
24019
276
302
338
960 ≤80
11 1100
51552
50128
48500
580
647
690
1450 16/13 14.5/6.1 ≤92 390
38664
37596
36375
326
364
387
960 ≤83
12 1200
62763
59300
55651
624
680
740
960 17/8 15/6.3 ≤93 485
47072
44475
43311
351
383
416
720 ≤83.5
13 1300
74708
65370
56031
600
710
807
960 17/8 15/6.3 ≤94 525
56031
49027
42023
338
399
454
720 ≤84.5
15 1500
93800
86115
76041
623
710
819
960 22/11 20/8.5 ≤95 655
70350
64586
57031
350
410
461
720 ≤85

XGF-I Type Fire High Temperature Smoke Exhaust Special Fan Outline Dimensional Table

model D1 D2 M1 M2 M3 M4 L H n-φ1 φ2
3.5 425 395 340 380 200 240 560 232 8-φ9 φ11
4 480 454 380 420 200 300 560 258 8-φ9 φ11
4.5 540 500 380 420 300 400 600 290 8-φ9 φ11
5 592 552 450 490 300 400 650 316 8-φ11 φ11
5.5 644 600 470 510 400 500 680 352 10-φ11 φ15
6 692 652 490 530 400 500 700 378 10-φ11 φ15
6.3 734 685 490 530 400 500 800 395 10-φ11 φ15
6.5 754 700 560 600 500 600 800 402 10-φ11 φ15
7 793 753 580 620 500 600 830 428 10-φ11 φ15
8 893 853 580 620 500 600 790 487 12-φ11 φ15
9 994 954 600 660 600 700 860 538 12-φ11 φ19
10 1096 1056 630 690 600 700 900 600 12-φ11 φ19
11 1218 1168 740 810 730 790 1060 650 14-φ13 φ19
12 1322 1272 840 910 870 930 1200 700 14-φ13 φ19
13 1422 1372 840 910 920 980 1200 750 16-φ13 φ21
15 1622 1572 840 910 1000 1100 1200 850 18-φ15 φ21

XGF-II Fire High Temperature Smoke Exhaust Special Fan Outline Dimensional Table

model D1 D2 M1 M2 M3 M4 L H n-φ1 φ2
5 592 552 450 490 300 400 650 316 8-φ11 φ11
5.5 644 600 470 510 400 500 680 352 10-φ11 φ15
6 692 652 490 530 400 500 700 378 10-φ11 φ15
6.5 754 700 560 650 500 600 800 402 10-φ11 φ15
7 793 753 610 670 500 600 870 428 10-φ11 φ15
8 893 853 610 670 500 600 870 487 12-φ11 φ15
9 994 954 650 710 600 700 900 538 12-φ11 φ19
10 1096 1056 660 720 600 700 950 600 12-φ11 φ19
11 1218 1168 810 880 730 790 1160 650 14-φ13 φ19
12 1322 1272 840 910 870 930 1200 700 14-φ13 φ19
13 1422 1372 840 910 920 980 1200 750 16-φ13 φ21
15 1622 1572 880 950 1000 1100 1200 850 18-φ15 φ21