E-mail
1987440091@qq.com
-
Phone
19901806598
-
Address
No. 77 Shenglong Road, Jiufu Development Zone, Songjiang District, Shanghai
Shanghai Prima Electronics Co., Ltd
1987440091@qq.com
19901806598
No. 77 Shenglong Road, Jiufu Development Zone, Songjiang District, Shanghai
PESD-20/30T1 is specifically designed to meet the requirements of electromagnetic compatibility electrostatic discharge (ESD) immunity testing, providing an evaluation basis for assessing the performance of electrical and electronic equipment when subjected to direct electrostatic discharge interference from operators and neighboring objects
>Ergonomic Design
>10.1-inch color touch screen operation
>Arbitrary conversion of positive and negative polarity
>Switchable between Chinese and English
>Custom, Boost, and Standard Modes
>Excellent craftsmanship, durable and long-lasting
>The maximum test voltage can reach 20kV
>Intelligent detection of air discharge failure
>RJ45 and RS232 interfaces, remote (optional)
>The discharge module is replaceable
>Support single continuous 20pps scan discharge mode
>Built in temperature and humidity time and real-time high voltage display
>The discharge electrode can be freely replaced
>IEC61000-6-1Radiation electric field requirements
>GR 1089Conducted and Radiated Disturbance Testing
>EN61326Electrical equipment for measurement, control, and laboratory useEMCRequirement:
>GB/T17626.2/EN/IEC61000-4-2Electrostatic discharge immunity test
>GB/T19951Test Method for Electrical Disturbance Caused by Static Discharge of Road Vehicles
>ISO10605Test Method for Electrical Interference Caused by Electrostatic Discharge in Highway Vehicles
>IEC61340-3-1Static induction simulation method, human body model(HBM)Static discharge test
>ITU-TK.20The resistance of telecommunications equipment installed in telecommunications centers to overvoltage and overcurrent
>IEC61326Electromagnetic compatibility requirements for electrical equipment used in measurement, control, and laboratory applications1part:General Requirements
| Product Model | PESD-20T1 | PESD-30T1 |
| contact discharge | 0.2KV~20KV(±5%) | 0.2KV~30KV(±5%) |
| air discharge | 0.2KV~20KV(±5%) | 0.2KV~20KV(±5%) |
| voltage range | 0.20kV ~20.0kV ±5% | |
| Voltage stepping | 0.0kV~10.0kV | |
| Voltage holding time | Greater than 5S | |
| output polarity | Positive/negative, positive first and then negative, negative first and then positive | |
| temperature and humidity | Built in temperature and humidity meter with recording and protection functions | |
| Discharge electrode | Sharp tip (contact discharge electrode) or round tip (air discharge electrode) | |
| discharge mode | Contact discharge, air discharge | |
| Discharge electrode | Contact discharge (pointed discharge electrode) | |
| Air discharge (spherical discharge electrode) | ||
| Discharge module | 1. Discharge capacitance: 150pF | |
| 2. Discharge resistance: 330 Ω | ||
| Pulse repetition frequency | Single/0.1/0.2/0.5/1/2/5/10/20Hz | |
| trigger mode | Single, manual, automatic triggering | |
| pulse counting | 1c~60000c | |
| rise time | 0.6~1.0ns | |
| General Parameters | ||
| display screen | 10.1-inch touch screen | |
| language | Switching between Chinese and English | |
| working power supply | AC 220V ± 10% 50/60Hz | |
| contact method | RJ45 | |
| ambient temperature | 18 ℃~28 ℃ (operating conditions) | |
| Low humidity | 30% to 60% (operating conditions) | |
| Pressure range | 86kPa~106 kPa (operating conditions) | |
| instrument power | 200W | |
| Overall dimensions | 490mm*445mm*185mm | |
| weight | 15kg | |
| Instrument working status indication | The front panel LED indicator light is on in red | |