E-mail
sfybkj@163.com
-
Phone
18915199993
-
Address
No. 8-6 Kejian Road, Dailou Industrial Park, Jinhu County, Jiangsu Province
Jiangsu Sanfeng Instrument Technology Co., Ltd
sfybkj@163.com
18915199993
No. 8-6 Kejian Road, Dailou Industrial Park, Jinhu County, Jiangsu Province
Product Details
The SF-80XY integrated temperature transmitter has the basic functions of a regular SF-80XY integrated temperature transmitter. It organically integrates temperature sensing elements (thermistor or thermocouple) with signal conversion and amplification units. In addition to outputting 4-20mA signals that are linear with temperature, it also has on-site indication or display functions.
The MCT80X display and transmission integrated temperature transmitter has a sturdy and beautiful shell, double-layer structure, 3-level LCD or LED display, and optional 0-100% pointer indication. The internal circuit adopts large-scale integrated circuit, stable signal, clear display, and is very convenient for on-site calibration and inspection. This instrument is divided into two types: ordinary type and explosion-proof type.
characteristic:
Accurate signal and long-distance transmission (up to 1000 meters)
High precision, anti-interference, good long-term stability, maintenance free
The transmitter can display measurements on site
Range: -200 ℃ to 1200 ℃; Conventional accuracy: ± 0.25%
working principle:
The temperature sensor is affected by temperature and produces resistance or potential effects, which are converted into a differential voltage signal. This signal is amplified by an amplifier and then converted into a 4-20mA current signal corresponding to the range through voltage and current conversion.
Technical indicators:
Technical indicators of the project
Temperature measurement range of thermistor -200~450 ℃; -50~150℃
Thermocouple temperature measurement range: 0 ℃ -1200 ℃; 0℃-800℃;0℃-1600℃0℃-1800℃
Measurement accuracy<thermal resistance>± 0.25%; ± 0.5%; <Thermocouple>± 0.75%
output signal
Temperature drift 4-20mA
± 0.025%/℃
Time drift less than ± 0.5% per year
Environmental temperature -10~85 ℃
Supply voltage 24V DC ± 10%
Load capacity 0-500 Ω
Display range -1999 to 1999
Protection level IP65
Explosion proof level dII BT6
Protective tube material 1Cr18Ni9Ti or ceramic or steel jade tube
Usage and Calibration:
The DC24V power supply supplies power to the transmitter through a shielded cable, with the "V+" connected to the positive pole of 24VDC and the "V -" connected to the negative pole. These two wires simultaneously output a 4-20mA standard signal, which is used to connect the load in series. Z "is the zero adjustment potentiometer, and" S "is the full adjustment potentiometer. All potentiometers have been calibrated according to user requirements before leaving the factory. When errors occur due to factors such as line resistance and ambient temperature during use, simply adjust the zero potentiometer "Z" to correct them.
Outline dimension diagram:
Precautions for use:
The power supply of the temperature transmitter should not have spikes, and the calibration of the transmitter should be carried out 5 minutes after power on, and attention should be paid to the ambient temperature at that time. Do not open the cover of the digital transmitter at will to avoid moisture. The shell should be firmly grounded, and power and signal output should be transmitted using shielded cables. The crimping nut should be tightened to ensure airtightness. Be sure to use a wrench or other tool to tighten the nut during installation, and do not directly twist the meter head by hand to prevent breaking the internal circuit. To adjust the display direction, first loosen the "header fixing screws" on both sides, gently rotate them to the appropriate position (not exceeding 270 ℃), and then tighten the screws.
Product selection:
SF-80XY - Port - (℃) - Port - Port - Port - (L × I) - Port - Port Display Transmission Integrated Temperature Transmitter
Code input type
PPt100 thermistor
CCu50 thermistor
KK indexing thermocouple
EE indexing thermocouple
SS indexing thermocouple
M user specified
Code measurement range
(℃) User specified
Code installation method
C1M27×2
C2M16×1.5
C3 movable flange
C4 fixed flange
C5 Other (user specified)
Code protection tube material
G11Cr18Ni9Ti
G2304 stainless steel
G3316 stainless steel
G4 Ceramic
G5 steel jade tube
Code protection tube diameter
D1Φ12
D2Φ16
D3 user specified
Code insertion depth
L × IL × I=mm (user specified, L represents total length, I represents insertion depth)
Code Display Table
X1LCD
X2LED
X30-100% pointer
Code Options
N ordinary type
D Explosion proof type