Technical Indicators:
Working voltage: DC24V
Working current: Equipment standby<3mA (battery powered), data transmission<150mA, valve switch current<2A, solar constant current charging 500mA
Communication network: Supports GSM900 and 1800 MHz dual band, Phase 2/2+standard
Working temperature: -25~+70 º C
Product advantages:
lD45 sewage exhaust valve overflow monitoring terminalEquipped with valve control function, it can promptly sound an alarm (within 2 minutes) and close the valve (within 2 seconds) in case of overflow or spraying of the exhaust valve, preventing sewage from leaking out and polluting the natural environment such as soil and water resources
D45 sewage exhaust valve overflow monitoring terminalThe product is powered by solar energy (17.5V/20W), without the need for mains power, and can work continuously for 15 days when fully charged
The product comes with a built-in charging and discharging function, with overcharge and over discharge protection, and does not require the installation of a solar control panel, saving costs
Integrated data collection and GPRS wireless communication, low cost, and with data packet replacement function for network disconnection
lData is transmitted once every minute, with good real-time performance. Function description:
Realize the detection, control, and alarm functions of sewage exhaust valve leakage and overflow. Within 2 seconds of leakage, control the opening and closing of the exhaust valve, and notify the user and upper computer of the alarm data within 2 minutes when the network signal is normal
Support 2 IP addresses and 4 (SMS and) data uploads
Reserve 2 channels of 4-20mA acquisition and 2 channels of switch quantity acquisition
Equipped with alarm saving function, it can save 100 alarm data and query them
Data timing upload can be set from 1 minute to 1 day, with a default upload time of 1 minute