Welcome Customer !

Membership

Help

Beijing Liyangtaike Technology Co., Ltd
Custom manufacturer

Main Products:

intelligent-mfg>Products

Beijing Liyangtaike Technology Co., Ltd

  • E-mail

    leonlok@163.com

  • Phone

  • Address

    1011, 10th Floor, Block A, Building 1, Xirong Ge Building, No. 138 Changhua Road, Haidian District, Beijing

Contact Now

Chlorine moisture analyzer

NegotiableUpdate on 08/20
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The chlorine moisture analyzer uses the P2O5 electrolysis principle to measure Xe、Ar、Kr、He、D2、F2、N2、H2、O2、O3、HBr、PH3、SF6、Freon、C2H2、CO2、CH4、Natural gas, Especially suitable for measuring trace moisture in high-purity acidic gases such as Cl2, HCl, SO2, H2S, etc. (except for a few gases that undergo chemical reactions with phosphoric acid).

Product Details

Technical characteristics of chlorine moisture analyzer:

Suitable for moisture analysis of corrosive gases and flammable gases

Absolute measurement method, no need for recalibration, regenerate sensor electrode film layer if necessary

Ultra fast response

high sensitivity

Fully microprocessor controlled

Automatic range switching

Instrument startup self-test function

Compliant with NAMUR standards

Analysis principle of chlorine moisture analyzer:

The pentoxide phosphorus sensor uses the principle of electrolyzing water molecules into hydrogen and oxygen. This sensor consists of a glass cylinder and two parallel electrodes. The electrode material is selected according to the specific application (usually made of platinum or rhodium metal wire), and a thin layer of phosphoric acid H3PO4 film is coated between the two electrodes. The electrolysis current appearing between the two electrodes decomposes the water in the acid into H2 and O2. The ultimate product of this process is pentoxide phosphorus, which is a highly hygroscopic substance. Therefore, water is absorbed from the sample gas. Through continuous electrolysis, a balance is established between the water content of the sample gas and the water content after electrolysis. The electrolysis current is proportional to the water content in the sample gas, and the signal passes through The internal signal amplifier of the instrument processes the signal, and then displays and reads out the data. This principle is suitable for analysis Xe、Ar、Kr、He、D2、F2、N2、H2、O2、O3、HBr、PH3、SF6、Freon、C2H2、CO2、CH4、Natural gas, Especially suitable for measuring trace moisture in high-purity acidic gases such as Cl2, HCl, SO2, H2S, etc. (except for a few gases that undergo chemical reactions with phosphoric acid).

Technical Specifications:

Range: 0-10ppm/100ppm/1000ppm/2500ppm (automatic range)

Accuracy: 1% of the full range

Sensitivity: 0.1% of the full range

Analog output: 1 channel of analog output can be set to 0/4-20mA or 0-10V

Alarm output: 1 alarm output

Display: LCD display, backlight switchable

Sample gas flow rate: 20Nl/h

Suggested pressure: 0.1-0.5 barg

Sample gas temperature: 5-150 ℃

Response time:<1 second

T50 response:<8 seconds

Environmental temperature: 5-65 ℃

Cable: Standard 3 meters, maximum length 300 meters optional

Power supply: Built in rechargeable lead-acid battery or external mains power 80-230VAC@50-60Hz

Dimensions: Width 363mm x Height 115mm x Depth 377mm

Weight: Approximately 6Kg