Burkert00221657 Baode model 6213EV two position normally closed solenoid valve with coupling diaphragm, zero pressure start, can be widely used in liquid media. To open the valve *, a pressure difference of at least 0.1 bar is required. Our company represents the entire range of Baode products, with good prices, short lead times, and a large amount of stock. We welcome customers to inquire or provide parameters to help you select.
Burkert00221657 two position normally closed solenoid valve
System. Zero pressure start-up can be widely used in liquid media. To open the valve *, a pressure difference of at least 0.1 bar is required.
The burkert00270903 baode type 6213ev type 6213ev two usually closed solenoid valve band coupling diaphragm
System. Zero pressure start can be widely used in liquid media. At least 0.1bar differential pressure is required to fully open the valve.
Technical parameters of Burkert00221657 two position normally closed solenoid valve
inner hole
Valve body material: brass, stainless steel 1.4404
Valve internals
Brass valve body made of brass, stainless steel, and PPS
Stainless steel valve body, made of stainless steel and PPS
sealing material
Load cycle * continuous operation
Electrical connection DIN 43650 A-type plug, compatible with 2508 cable socket
Protection level with cable socket IP 65
Installation can be done as needed, with the coil facing upwards
Installation and Maintenance
-
Installation key points
- Flow direction identificationInstall in the direction of the valve body arrow to avoid sealing damage caused by reverse flow.
- vertical installationPriority should be given to vertical installation (with the valve core perpendicular to the ground) to reduce valve core wear (horizontal installation requires additional support brackets).
- electrical connectionEnsure the correct polarity of the power supply (24 V DC+connected to the "+" terminal) to avoid short circuits or reverse connections that may damage the coil.
- grounding protectionThe casing of the solenoid valve needs to be reliably grounded (grounding resistance<10 Ω) to prevent static electricity or lightning strikes.
-
routine maintenance
- regular inspectionCheck the sealing components for aging every 3 months (if cracks or deformations appear, they need to be replaced).
- Cleaning and maintenanceBlow the dust inside the valve body with compressed air (avoid using corrosive cleaning agents).
- Lubrication requirementsStainless steel valve bodies do not require lubrication, while brass valve bodies can be coated with a small amount of silicon-based grease (such as Molykote 111).
-
troubleshooting
-
Valve does not operate:
- Check if the power supply is normal (use a multimeter to measure if the voltage is within the rated range).
- Confirm if the coil is damaged (measure resistance value, open circuit indicates coil burnout).
-
Valve leakage:
- Check if the sealing components are installed properly or aged (replace with sealing rings of the same model).
- Confirm whether the medium contains particulate impurities (a filter with a filtration accuracy of ≥ 50 μ m needs to be installed).
-
Slow response:
- Check if the voltage is too low (such as 24 V DC dropping below 20 V will cause insufficient suction).
- Clean the impurities between the valve core and valve seat (wipe with a soft cloth to avoid scratching the sealing surface).